Evaluating the microgap and sealing capability in four implant systems with different interlockings under different tightening torques: an in-vitro study
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
PURPOSE. This study assessed the microgap width and adhesion of three bacterial species in four dental implants with different interlocks under four screwing torques. MATERIALS AND METHODS. Ten samples of four implant systems with various interlockings, including full-hexagonal (FHI), cylindrical-conical trilobe-index (TLI), Morse-taper with octagon terminal index (OI), and hexagonal interlock (slip-fit) (HI-SF), were used. The abutments were screwed to the fixtures under torques of 10, 20, 30, and 40 Ncm. The microgap between the abutment and the platform was assessed using a Scanning Electron Microscope (SEM). The leakage of 3 bacteria, including Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa, was evaluated under 30 Ncm torque. RESULTS. The TLI system showed the widest gap under all torques compared to others. There was no significance among all systems under different screwing torques. Regarding the leakage, there was no adherence to E. coli and S. aureus and 36.4% of Ps. aeruginosa to the HI-SF, followed by the OI system. The FHI and TLI systems showed the highest bacterial adherence. CONCLUSION. Even with low torque, the studied systems showed gap widths narrower than acceptable width. Implant systems with FHI and OI demonstrated misfits of less than 2 µm upon 10 Ncm and less than 1 µm when the torque increases, giving them priority to be used in areas with poor bone quality. The HI-SF demonstrated a high ability to resist the adherence to E. coli and S. aureus, followed by OI. However, Ps. aeruginosa demonstrated a high ability to adhere to all systems.
Abstract
PURPOSE. This study assessed the microgap width and adhesion of three bacterial species in four dental implants with different interlocks under four screwing torques. MATERIALS AND METHODS. Ten samples of four implant systems with various interlockings, including full-hexagonal (FHI), cylindrical-conical trilobe-index (TLI), Morse-taper with octagon terminal index (OI), and hexagonal interlock (slip-fit) (HI-SF), were used. The abutments were screwed to the fixtures under torques of 10, 20, 30, and 40 Ncm. The microgap between the abutment and the platform was assessed using a Scanning Electron Microscope (SEM). The leakage of 3 bacteria, including Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa, was evaluated under 30 Ncm torque. RESULTS. The TLI system showed the widest gap under all torques compared to others. There was no significance among all systems under different screwing torques. Regarding the leakage, there was no adherence to E. coli and S. aureus and 36.4% of Ps. aeruginosa to the HI-SF, followed by the OI system. The FHI and TLI systems showed the highest bacterial adherence. CONCLUSION. Even with low torque, the studied systems showed gap widths narrower than acceptable width. Implant systems with FHI and OI demonstrated misfits of less than 2 µm upon 10 Ncm and less than 1 µm when the torque increases, giving them priority to be used in areas with poor bone quality. The HI-SF demonstrated a high ability to resist the adherence to E. coli and S. aureus, followed by OI. However, Ps. aeruginosa demonstrated a high ability to adhere to all systems.
참고문헌 (60)
- Kochar SP, "The etiology and management of dental implant failure : a review", Cureus, 14, pp.e30455~ (2022)
- Romanos GE, "Concepts for prevention of complications in implant therapy", Periodontol 2000, 81, pp.7~17 (2019)
- Samara W, "Dental implant placement in medically compromised patients : a literature review", Cureus, 16, pp.e54199~ (2024)
- Monje A, "Impact of local predisposing", precipitating factors and systemic drivers on peri-implant diseases, 2023, pp.25, 640~660
- Zheng Z, "The biological width around implant", J Prosthodont Res, 65, pp.11~18 (2021)
- Bishti S, "Effect of the implant-abutment interface on peri-implant tissues : a systematic review", Acta Odontol Scand, 72, pp.13~25 (2014)
- Sghaireen MG, "A CBCT based three-dimensional assessment of mandibular posterior region for evaluating the possibility of bypassing the inferior alveolar nerve while placing dental implants", Diagnostics(Basel), 10, pp.406~ (2020)
- Gehrke SA, "Effects of different torque levels on the implant-abutment interface in a conical internal connection", Braz Oral Res, 30, pp.S1806-83242016000100233~ (2016)
- Mishra SK, "Microleakage at the different implant abutment interface : a systematic review", J Clin Diagn Res, 11, pp.ZE10~ZE15 (2017)
- Lauritano D, "The impact of implant-abutment connection on clinical outcomes and microbial colonization : a narrative review", Materials(Basel), 13, pp.1131~ (2020)
- Ceruso FM, "Implant-abutment connections on single crowns : a systematic review", Oral Implantol(Rome), 10, pp.349~353 (2017)
- Tsuge T, "Marginal fit and microgaps of implant-abutment interface with internal anti-rotation configuration", Dent Mater J, 27, pp.29~34 (2008)
- Katsoulis J, "CAD", CAM fabrication accuracy of long-vs. short-span implant-supported FDPs, 2015, pp.26, 245~249
- Jokstad A, "New 3D technologies applied to assess the long-term clinical effects of misfit of the full jaw fixed prosthesis on dental implants", Clin Oral Implants Res, 26, pp.1129~1134 (2015)
- Pan Y, "Implant framework misfit : a systematic review on assessment methods and clinical complications", Clin Implant Dent Relat Res, 23, pp.244~258 (2021)
- Kano SC, "A classification system to measure the implant-abutment microgap", Int J Oral Maxillofac Implants, 22, pp.879~885 (2007)
- Baggi L, "Microbiological evaluation of bacterial and mycotic seal in implant systems with different implant-abutment interfaces and closing torque values", Implant Dent, 22, pp.344~350 (2013)
- Alshubrmi H, "Influences of different torques on the size of the microgap and bacterial leakage in different implant systems : an in-vitro study", Int J Prosthodont, 0, pp.1~25 (2024)
- Goiato MC, "Is the internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? a systematic review", Oral Maxillofac Surg, 19, pp.229~242 (2015)
- Vinhas AS, "Review of the mechanical behavior of different implant-abutment connections", Int J Environ Res Public Health, 17, pp.8685~ (2020)
- Saidin S, "Effects of different implant-abutment connections on micromotion and stress distribution : prediction of microgap formation", J Dent, 40, pp.467~474 (2012)
- Cascos R, "Influence of the use of transepithelial abutments vs. titanium base abutments on microgap formation at the dental implant–abutment interface : an in vitro study", Materials, 16, pp.6532~ (2023)
- Lorusso F, "Effect of different dental implant prosthetic joints on marginal bone loss : emerging findings from a bayesian network meta-analysis(NMA)and systematic review", Prosthesis, 6, pp.186~205 (2024)
- Back S, "Comparative study of axial displacement in digital and conventional implant prosthetic components", Sci Rep, 14, pp.19185~ (2024)
- Kim KS, "Axial displacements and removal torque changes of five different implant-abutment connections under static vertical loading", Materials, 13, pp.699~ (2020)
- Goyeneche VP, "Does the index in Morse taper connection affect the abutment stability? An in vitro experimental study", PLoS One, 19, pp.e0298462~ (2024)
- Zhang WT, "Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone : a 3D finite element analysis", BMC Oral Health, 22, pp.431~ (2022)
- Villarinho EA, "The effect of a positioning index on the biomechanical stability of tapered implant-abutment connections", J Oral Implantol, 41, pp.139~143 (2015)
- de Oliveira Silva TS, "Effect of internal hexagonal index on removal torque and tensile removal force of different Morse taper connection abutments", J Prosthet Dent, 117, pp.621~627 (2017)
- Shen L, "The mechanical and clinical influences of prosthetic index structure in Morse taper implant-abutment connection : a scoping review", BMC Oral Health, 23, pp.775~ (2023)
- Romanos GE, "Bacterial composition at the implant-abutment connection under loading in vivo", Clin Implant Dent Relat Res, 18, pp.138~145 (2016)
- Rismanchian M, "Evaluation of microgap size and microbial leakage in the connection area of 4 abutments with Straumann(ITI)implant", J Oral Implantol, 38, pp.677~685 (2012)
- Bittencourt ABBC, "Comparison of the morse cone connection with the internal hexagon and external hexagon connections based on microleakage-review", Prague Med Rep, 122, pp.181~190 (2021)
- Resende CC, "Influence of the prosthetic index into morse taper implants on bacterial microleakage", Implant Dent, 24, pp.547~551 (2015)
- Canullo L, "Microbiological assessment of the implant-abutment interface in different connections : cross-sectional study after 5 years of functional loading", Clin Oral Implants Res, 26, pp.426~434 (2015)
- Cavusoglu Y, "A pilot study of joint stability at the zirconium or titanium abutment", titanium implant interface, 2014, pp.29, 338~343
- Sahin C, "Correlation between microleakage and screw loosening at implant-abutment connection", J Adv Prosthodont, 6, pp.35~38 (2014)
- Smith NA, "Evaluation of the sealing capability of implants to titanium and zirconia abutments against Porphyromonas gingivalis, Prevotella intermedia, and Fusobacterium nucleatum under different screw torque values", J Prosthet Dent, 112, pp.561~567 (2014)
- do Nascimento C, "Bacterial leakage along the implant-abutment interface : culture and DNA Checkerboard hybridization analyses", Clin Oral Implants Res, 23, pp.1168~1172 (2012)
- D’Ercole S, "Bacterial microleakage at the implant-abutment interface : an in vitro study", Bioengineering(Basel), 9, pp.277~ (2022)
- Mousa MA, "Denture-related stomatitis in new complete denture wearers and its association with Candida species colonization : a prospective case-series", Quintessence Int, 51, pp.554~565 (2020)
- Mousa MA, "Prospective case series on possible effects of local factors on the development of halitosis in new complete denture wearers", Quintessence Int, 53, pp.218~225 (2022)
- Jacob ME, "Optimizing a screening protocol for potential extended-spectrum β-lactamase Escherichia coli on MacConkey agar for use in a global surveillance program", J Clin Microbiol, 58, pp.e01039-19~ (2020)
- Shields P, "Oxidase test protocol", pp.1~9 (2010), American Society for Microbiology
- Fernandes Queiroga Moraes G, "Main laboratory methods used for the isolation and identification of Staphylococcus Spp", Rev Colomb Cienc Quim Farm, 50, pp.5~28 (2021)
- Krall EA, "Heritable and life-style determinants of bone mineral density", J Bone Miner Res, 8, pp.1~9 (1993)
- Papaspyridakos P, "Implant loading protocols for edentulous patients with fixed prostheses : a systematic review and meta-analysis", Int J Oral Maxillofac Implants, 29(Suppl), pp.256~270 (2014)
- Schimmel M, "Loading protocols for implant-supported overdentures in the edentulous jaw : a systematic review and meta-analysis", Int J Oral Maxillofac Implants, 29(Suppl), pp.271~286 (2014)
- Schrott A, "Implant loading protocols for partially edentulous patients with extended edentulous sites-a systematic review and meta-analysis", Int J Oral Maxillofac Implants, 29(Suppl), pp.239~255 (2014)
- Herbst PE, "Influence of different screw torque levels on the biomechanical behavior of tapered prosthetic abutments", Int J Oral Maxillofac Implants, 33, pp.536~540 (2018)
- Enkling N, "Soft tissue response to different abutment materials : A controlled and randomized human study using an experimental model", Clin Oral Implants Res, 33, pp.667~679 (2022)
- Nascimento C, "Microbiome of titanium and zirconia dental implants abutments", Dent Mater, 32, pp.93~101 (2016)
- D’Ercole S, "Bacterial leakage in Morse Cone internal connection implants using different torque values : an in vitro study", Implant Dent, 23, pp.175~179 (2014)
- Scarano A, "A 16-year study of the microgap between 272 human titanium implants and their abutments", J Oral Implantol, 31, pp.269~275 (2005)
- Assenza B, "Bacterial leakage in implants with different implant-abutment connections : an in vitro study", J Periodontol, 83, pp.491~497 (2012)
- Carvalho ÉBS, "Microbiota associated with peri-implantitis-a systematic review with meta-analyses", Clin Oral Implants Res, 34, pp.1176~1187 (2023)
- Koutouzis T, "The effect of dynamic loading on bacterial colonization of the dental implant fixture-abutment interface : an in vitro study", J Oral Implantol, 40, pp.432~437 (2014)
- Heitz-Mayfield LJ, "Comparative biology of chronic and aggressive periodontitis vs. peri-implantitis", Periodontol 2000, 53, pp.167~181 (2010)
- Discepoli N, "Sealing effectiveness against Staphylococcus aureus of five different implant-abutment connections", Am J Dent, 31, pp.141~143 (2018)
- Nassar HI, "Bacterial leakage of different internal implant", abutment connection, 2015, pp.1, 1~5
