국제 기준 공기식 태양열 집열기 열 성능 평가 연구

Study on Solar Air Thermal Performance Test based on International Standard

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류기타공학

초록

Solar air thermal collectors are one of the technologies used to improve the efficiency of fresh air heating system in building spaces. Solar air collectors have the advantage of preventing freezing and overheating problems when compared with solar water collectors. However, thus far, there have been no harmonized thermal performance test facilities or round robin tests (RRT) based on the international standard ISO 9806 in Korea. In this study, an ISO 9806 thermal performance test facility was introduced and designed. In addition, an RRT was conducted based on ISO 9806 and compared to RRT sample Exova performance test results to verify the consistency of the thermal performance. The thermal efficiency ranged 36.06% ~ 72.02% depending on a change flow rate change of 36.6 ~ 182.9 m3/(hr·m2), respectively. The RRT was successfully conducted to compare the results of the Exova thermal performance test. A comparison between the Exova and KIER tests showed a relative error of 5.51% and 6.42% for ambient wind velocities of 1.0 and 1.8 m/s, respectively.

Abstract

Solar air thermal collectors are one of the technologies used to improve the efficiency of fresh air heating system in building spaces. Solar air collectors have the advantage of preventing freezing and overheating problems when compared with solar water collectors. However, thus far, there have been no harmonized thermal performance test facilities or round robin tests (RRT) based on the international standard ISO 9806 in Korea. In this study, an ISO 9806 thermal performance test facility was introduced and designed. In addition, an RRT was conducted based on ISO 9806 and compared to RRT sample Exova performance test results to verify the consistency of the thermal performance. The thermal efficiency ranged 36.06% ~ 72.02% depending on a change flow rate change of 36.6 ~ 182.9 m3/(hr·m2), respectively. The RRT was successfully conducted to compare the results of the Exova thermal performance test. A comparison between the Exova and KIER tests showed a relative error of 5.51% and 6.42% for ambient wind velocities of 1.0 and 1.8 m/s, respectively.

참고문헌 (10)

  1. "Korea Ministry of Land, Infrastructure and Transport, Notification 2019-179, Regulations on Zero Energy Building", ~ (2019)
  2. Mcquiston, F. C., "Heating, Ventilating and Air Conditioning Analysis and Design", pp.299~365 (2005), John Wiley & Sons, Inc
  3. Duffie, J. A., "Solar Engineering of Thermal Process", pp.202~321 (2013), Wiley-Interscience Publication
  4. Akpinar, E. K., "Experimental Investigation of Thermal Performance of Solar Air Heater Having Different Obstacles on Absorber Plates", International Communications in Heat and Mass Transfer, 37(4), pp.416~421 (2010)
  5. Tanda, G., "Performance of Solar Air Heater Ducts with Different Types of Ribs on the Absorber Plate", Energy, 36(11), pp.6651~6660 (2011)
  6. Bahrehmand, D., "Energy and Exergy Analysis of Different Solar Air Collector Systems with Natural Convection", Renewable Energy, 74, pp.357~368 (2015)
  7. Bahrehmand, D., "Energy and Exergy Analysis of Different Solar Air Collector Systems with Forced Convection", Renewable Energy, 83, pp.1119~1130 (2015)
  8. Sun, C., "A Mathematical Model to Investigate on the Thermal Performance of a Flat Plate Solar Air Collector and Its Experimental Verification", Energy Conversion and Managementm, 115(1), pp.43~51 (2016)
  9. "International Standard ISO 9806 Solar Energy, Solar Thermal Collector Test Methods", ISO, ~ (2017)
  10. Air-Heating Solar Collector Test Report, "Exova", Mississauga Ontario Canada, ~ (2015)