본문 바로가기
KERD
논문

IoT 기반 지하역사 내 바이오필터시스템 설치에 따른 실내공기질 변화 및 영향 요인 분석

Analysis of Changes and Factors Influencing IAQ in Subway Stations Using IoT Technology after Bio-Filter System Installation

3

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

Background: Subway stations have the characteristics of being located underground and are a representative public-use facility used by an unspecified number of people. As concerns about indoor air quality (IAQ) increase, various management measures are being implemented. However, there are few systematic studies and cases of long-term continuous measurement of underground station air quality. Objectives: The purpose of this study is to analyze changes and factors influencing IAQ in subway stations through real-time continuous long-term measurement using IoT-based IAQ sensing equipment, and to evaluate the IAQ improvement effect of a bio-filter system. Methods: The IAQ of a subway station in Seoul was measured using IoT-based sensing equipment. A bio- filter system was installed after collecting the background concentrations for about five months. Based on the data collected over about 21 months, changes in indoor air quality and influencing factors were analyzed and the reduction effect of the bio-filter system was evaluated. Results: As a result of the analysis, PM10, PM2.5, and CO2 increased during rush hour according to the change in the number of passengers, and PM10 and PM2.5 concentrations were high when a PM warning/watch was issued. There was an effect of improving IAQ with the installation of the bio-filter system. The reduction rate of a new-bio-filter system with improved efficiency was higher than that of the existing bio-filter system. Factors affecting PM2.5 in the subway station were the outdoor PM2.5, platform PM2.5, and the number of passengers. Conclusions: The IAQ in a subway station is affected by passengers, ventilation through the air supply and exhaust, and the spread of particulate matter generated by train operation. Based on these results, it is expected that IAQ can be efficiently improved if a bio-filter system with improved efficiency is developed in consideration of the factors affecting IAQ and proper placement.

Abstract

Background: Subway stations have the characteristics of being located underground and are a representative public-use facility used by an unspecified number of people. As concerns about indoor air quality (IAQ) increase, various management measures are being implemented. However, there are few systematic studies and cases of long-term continuous measurement of underground station air quality. Objectives: The purpose of this study is to analyze changes and factors influencing IAQ in subway stations through real-time continuous long-term measurement using IoT-based IAQ sensing equipment, and to evaluate the IAQ improvement effect of a bio-filter system. Methods: The IAQ of a subway station in Seoul was measured using IoT-based sensing equipment. A bio- filter system was installed after collecting the background concentrations for about five months. Based on the data collected over about 21 months, changes in indoor air quality and influencing factors were analyzed and the reduction effect of the bio-filter system was evaluated. Results: As a result of the analysis, PM10, PM2.5, and CO2 increased during rush hour according to the change in the number of passengers, and PM10 and PM2.5 concentrations were high when a PM warning/watch was issued. There was an effect of improving IAQ with the installation of the bio-filter system. The reduction rate of a new-bio-filter system with improved efficiency was higher than that of the existing bio-filter system. Factors affecting PM2.5 in the subway station were the outdoor PM2.5, platform PM2.5, and the number of passengers. Conclusions: The IAQ in a subway station is affected by passengers, ventilation through the air supply and exhaust, and the spread of particulate matter generated by train operation. Based on these results, it is expected that IAQ can be efficiently improved if a bio-filter system with improved efficiency is developed in consideration of the factors affecting IAQ and proper placement.

참고문헌 (34)

  1. Shiotsu M, "Survey on human activity patterns according to time and place : basic research on the exposure dose to indoor air pollutants Part 1", J Archit Plan, 63(511), pp.45~52 (1998)
  2. Guieysse B, "Biological treatment of indoor air for VOC removal : potential and challenges", Biotechnol Adv, 26(5), pp.398~410 (2008)
  3. Orwell RL, "Removal of benzene by the indoor plant", substrate microcosm and implications for air quality, 2004, pp.157, 193~207
  4. "American Time Use Survey (ATUS)"[URL]
  5. World Health Organization, "WHO Guidelines for Indoor Air Quality: Selected Pollutants", WHO, ~ (2010)
  6. "Life Time Survey"[URL]
  7. "Public Transport Distribution Rate"[URL]
  8. 홍종호, "다중이용시설 실내공기질 개선의 경제적 가치 추정: 서울시 지하역사를 중심으로", 한국경제연구, 17, pp.169~198 (2006), 한국경제연구학회
  9. 임봉빈, "서울시 지하역사 실내오염물질 농도자료의 통계분석을 통한 실내공기질 특성 평가", 한국대기환경학회지, 30(3), pp.233~244 (2014), 한국대기환경학회[DOI]
  10. Toxic Exposure Assessment: A Columbia-Harvard (TEACH)Study (the New York City Report), "Kinney PL", NUATRC, ~, pp.Mickey Leland National Urban Air Toxics Research Center Research Report 3 (2005)
  11. Adachi M, "Effects of floral and foliage displays on human emotions", HortTechnology, 10(1), pp.59~63 (2000)
  12. Bringslimark T, "The psychological benefits of indoor plants : a critical review of the experimental literature", J Environ Psychol, 29(4), pp.422~433 (2009)
  13. Wood RA, "Potted-plant", growth media interactions and capacities for removal of volatiles from indoor air, 2002, pp.77(1), 120~129
  14. Cao Y, "Assisted deposition of PM2.5 from indoor air by ornamental potted plants", Sustainability, 11(9), pp.2546~ (2019)
  15. 김영미, "사물인터넷 환경에서의 사용자 경험 연구 동향", Journal of Integrated Design Research, 16(3), pp.19~29 (2017), 디자인연구소
  16. 이정훈, "실내거주자 건강 관리를 위한 IoT기반 실내정원용 IAQ지수 개발", 한국환경보건학회지, 44(5), pp.421~432 (2018), 한국환경보건학회
  17. 노진호, "사물인터넷기반 미세먼지 측정 시스템 구현", 한국정보통신학회논문지, 21(4), pp.829~835 (2017), 한국정보통신학회[DOI]
  18. Benammar M, "A modular IoT platform for real-time indoor air quality monitoring", Sensors(Basel), 18(2), pp.581~ (2018)
  19. Jo JH, "Implementation of IoT-based air quality monitoring system for investigating particulate matter(PM10)in subway tunnels", Int J Environ Res Public Health, 17(15), pp.5429~ (2020)
  20. Pradityo F, "Indoor air quality monitoring and controlling system based on IoT and Fuzzy logic", 20197th International Conference on Information and Communication Technology (ICoICT) (2019), IEEE
  21. Mumtaz R, "Internet of Things(IoT)based indoor air quality sensing and predictive analytic-a COVID-19 perspective", Electronics, 10(2), pp.184~209 (2021)
  22. "Seoul Transportation Corporation’s Transportation Performance"[URL]
  23. "Indoor Air Quality Control Act, Article 5 (Standards for maintenance of indoor air quality, etc.); Indoor Air Quality Control Act Enforcement Regulations, Article 3 (Standards for maintenance of indoor air quality)", ~ (2019)
  24. 박동욱, "서울 일부 지하철 객차와 승차장에서 측정한 PM10과PM2.5농도의 특성", 한국환경보건학회지, 31(1), pp.39~46 (2005), 한국환경보건학회
  25. Lee JY, "Study of pollution concentration source and its change pattern in underground station", 2012 SAREK Summer Annual Conference, pp.547~550 (2012)
  26. Partti-Pellinen K, "Penetration of nitrogen oxides and particles from outdoor into indoor air and removal of the pollutants through filtration of incoming air", Indoor Air, 10(2), pp.126~132 (2000)
  27. Shao Y, "The impact of indoor living wall system on air quality: a comparative monitoring test in building corridors", Sustainability, 13(14), pp.7884~ (2021)
  28. Pettit T, "Do the plants in functional green walls contribute to their ability to filter particulate matter? Build Environ", Build Environ, 125(15), pp.299~307 (2017)
  29. Torpy F, "Bench-study of green-wall plants for indoor air pollution reduction", J Living Archit, 5(1), pp.1~15 (2018)
  30. 주진희, "실내녹화 부피비율이 실공간의 미세분진농도, 온도 및 상대습도에 미치는 영향", 한국환경복원기술학회지, 13(2), pp.1~7 (2010), 한국환경복원기술학회
  31. 곽윤경, "초등학교 교실 내 식물의 식재량에 따른 실내공기질 및 재실자 건강 점수 변화", 실내환경 및 냄새 학회지, 14(3), pp.190~198 (2015), 한국냄새환경학회[DOI]
  32. Chao CYH, "Influence of different indoor activities on the indoor particulate levels in residential buildings", Indoor Built Environ, 7(2), pp.110~121 (1998)
  33. He C, "Contribution from indoor sources to particle number and mass concentrations in residential houses", Atmos Environ, 38(21), pp.3405~3415 (2004)
  34. 박종헌, "지하철 역사 미세먼지(PM10)의 확산방향과 확산속도 추정 (서울 지하철 5호선 개화산역을 대상으로)", 대한교통학회지, 28(5), pp.55~64 (2010), 대한교통학회

관련 논문AI추천

이 간행물의 다른 논문 (12건)