The Safety and Efficacy of Transconjunctival Sutureless 23-gauge Vitrectomy
0
조회
0
다운로드
6
인용
0
참고문헌
초록
Abstract
Purpose: To evaluate the efficacy and safety of vitreoretinal surgery using a 23-gauge transconjunctival sutureless vitrectomy (TSV) system for various vitreoretinal diseases. Methods: A retrospective, consecutive, interventional case series was performed for 40 eyes of 40 patients. The patients underwent vitreoretinal procedures using the 23-gauge TSV system, including idiopathic epiretinal membrane (n=7), vitreous hemorrhage (n=11), diabetic macular edema (n=10), macular hole (n=5), vitreomacular traction syndrome (n=5), diabetic tractional retinal detachment (n=1), and rhegmatogenous retinal detachment (n=1). Best corrected visual acuity (BCVA), intraocular pressure (IOP), and intra- and post-operative complications were evaluated. Results: Intraoperative suture placement was necessary in 3 eyes (7.5%). The median BCVA improved from 20/400 (LogMAR, 1.21±0.63) to 20/140 (LogMAR, 0.83±0.48) at 1 week (p=0.003), 20/100 (LogMAR, 0.85±0.65) at 1 month (p=0.002), 20/100 (LogMAR, 0.73±0.6) at 3 months (p=0.001). In 1 eye, IOP was 5 mmHg at 2 hours and 4 mmHg at 5 hours, but none of the eyes showed hypotony after 1 postoperative day. No serous postoperative complications were observed during a mean follow-up of 8.4±3.4 months (range 3-13 months) Conclusions: The 23-gauge TSV system shows promise as an effective and safe technique for a variety of vitreoretinal procedures. It appears to be a less traumatic, more convenient alternative to 20-gauge vitrectomy in some indications.
참고문헌 (9)
- Fujii GY, "A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery", 109, pp.1807~1812 (2002)
- Fujii GY, "Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery", 109, pp.1814~1820 (2002)
- Eckardt C, "Transconjunctival sutureless 23-gauge vitrectomy", 25, pp.208~211 (2005)
- Yoon YH, "Sutureless vitreoretinal surgery using a new 25-gauge transconjunctival system", 37, pp.12~19 (2006)
- O' Reilly P, "Transconjunctival sutureless vitrectomy: initial experience and surgical tips", 21, pp.518~521 (2007)
- Lakhanpal RR, "Outcomes of 140 consecutive cases of 25-gauge transconjunctival surgery for posterior segment disease", 112, pp.817~824 (2005)
- Ibarra MS, "Longer-term outcomes of transconjunctival sutureless 25-gauge vitrectomy", 139, pp.831~836 (2005)
- Hwang J, "Combined phacoemulsification, foldable intraocular lens implantation, and 25-gauge transconjunctival sutureless vitrectomy", 32, pp.727~731 (2006)
- Kellner L, "25 Gauge versus 20 Gauge System for Pars Plana Vitrectomy: A Prospective Randomized Clinical Trial", 91, pp.945~948 (2007)