Determination of Urinary Iodine Concentration by Inductively Coupled Plasma-mass Spectrometry in Thyroid Cancer Patients on Low-iodine Diet
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Background : Thyroid cancer patients should be on low-iodine diet (LID) before radioactive iodine therapy (RAIT) to maximize the effect of RAIT. Urinary iodine excretion is the most accurate marker of very recent dietary iodine intake. We developed and evaluated the analytical performance of inductively coupled plasma-mass spectrometry (ICP-MS) to determine urinary iodine concentration. Methods : We evaluated the linearity, precision, accuracy, and lower limit of quantification (LLOQ) of an ICP-MS method (Agilent 7500ce) to determine urinary iodine concentration in accordance with the Food and Drug Administration (FDA) guidelines for bioanalytical method validation. This method was used to determine and compare the iodine concentration in random urine samples of 120 thyroid cancer patients on LID for 1 week and 80 healthy adults on normal diet. Results : Our ICP-MS method showed good linearity (1.0-1,913 mg/L; R2>0.999). Both intra-day and inter-day precision CV were within 20% for the LLOQ (1 mg/L) and within 15% for the other concentrations. Accuracy was 110-120% for the LLOQ and 95-115% for the other concentrations. The median concentration of iodine in random urine samples from thyroid cancer patients on LID (38.7 mg/L) was significantly lower than that of healthy subjects (238.8 mg/L) (P<0.0001). Conclusions : Urinary iodine analysis by ICP-MS showed good linearity, precision, accuracy, wide measuring range of detection, and lower LLOQ. This method will be very useful to evaluate the status of dietary iodine intake and the appropriateness of LID in thyroid cancer patients, thereby maximizing the effect of RAIT. (Korean J Lab Med 2010;30:351-6)
Abstract
Background : Thyroid cancer patients should be on low-iodine diet (LID) before radioactive iodine therapy (RAIT) to maximize the effect of RAIT. Urinary iodine excretion is the most accurate marker of very recent dietary iodine intake. We developed and evaluated the analytical performance of inductively coupled plasma-mass spectrometry (ICP-MS) to determine urinary iodine concentration. Methods : We evaluated the linearity, precision, accuracy, and lower limit of quantification (LLOQ) of an ICP-MS method (Agilent 7500ce) to determine urinary iodine concentration in accordance with the Food and Drug Administration (FDA) guidelines for bioanalytical method validation. This method was used to determine and compare the iodine concentration in random urine samples of 120 thyroid cancer patients on LID for 1 week and 80 healthy adults on normal diet. Results : Our ICP-MS method showed good linearity (1.0-1,913 mg/L; R2>0.999). Both intra-day and inter-day precision CV were within 20% for the LLOQ (1 mg/L) and within 15% for the other concentrations. Accuracy was 110-120% for the LLOQ and 95-115% for the other concentrations. The median concentration of iodine in random urine samples from thyroid cancer patients on LID (38.7 mg/L) was significantly lower than that of healthy subjects (238.8 mg/L) (P<0.0001). Conclusions : Urinary iodine analysis by ICP-MS showed good linearity, precision, accuracy, wide measuring range of detection, and lower LLOQ. This method will be very useful to evaluate the status of dietary iodine intake and the appropriateness of LID in thyroid cancer patients, thereby maximizing the effect of RAIT. (Korean J Lab Med 2010;30:351-6)
참고문헌 (32)
- Cooper DS, "Management guidelines for patients with thyroid nodules and differentiated thyroid cancer", Thyroid, 16, pp.109~142 (2006)
- Luster M, "Guidelines for radioiodine therapy of differentiated thyroid cancer", Eur J Nucl Med Mol Imaging, 35, pp.1941~1959 (2008)
- Sawka AM, "Clinical review 170: a systematic review and metaanalysis of the effectiveness of radioactive iodine remnant ablation for well-differentiated thyroid cancer", J Clin Endocrinol Metab, 89, pp.3668~3676 (2004)
- Cavalieri RR, "Iodine metabolism and thyroid physiology: current concepts", Thyroid, 7, pp.177~181 (1997)
- Andersson M, "Current global iodine status and progress over the last decade towards the elimination of iodine deficiency", Bull World Health Organ, 83, pp.518~525 (2005)
- Zimmermann MB, "Iodine requirements and the risks and benefits of correcting iodine deficiency in populations", J Trace Elem Med Biol, 22, pp.81~92 (2008)
- Demers LM, "Laboratory medicine practice guidelines:laboratory support for the diagnosis and monitoring of thyroid disease", Clin Endocrinol, 58, pp.138~140 (2003)
- Caldwell KL, "Use of inductively coupled plasma mass spectrometry to measure urinary iodine in NHANES 2000: comparison with previous method", Clin Chem, 49, pp.1019~1021 (2003)
- Macours P, "Determination of urinary iodine by inductively coupled plasma mass spectrometry", J Trace Elem Med Biol, 22, pp.162~165 (2008)
- May SL, "Validation of a simple, manual urinary iodine method for estimating the prevalence of iodine-deficiency disorders, and interlaboratory comparison with other methods", Am J Clin Nutr, 65, pp.1441~1445 (1997)
- U.S. Food and Drug Administration, "Center for Drug Evaluation and Research. Guidance for industry: bioanalytical method validation", U.S. Department of Health and Human Services, Food and Drug Administration, ~ (2001)
- Guan H, "Association of high iodine intake with the T1799A BRAF mutation in papillary thyroid cancer", J Clin Endocrinol Metab, 94, pp.1612~1617 (2009)
- Teng W, "Effect of iodine intake on thyroid diseases in China", N Engl J Med, 354, pp.2783~2793 (2006)
- Harach HR, "Thyroid cancer, thyroiditis and dietary iodine: a review based on the Salta, Argentina model", Endocr Pathol, 19, pp.209~220 (2008)
- Kim JY, "Dietary iodine intake and urinary iodine excretion in patients with thyroid diseases", Yonsei Med J, 41, pp.22~28 (2000)
- Pennington JA, "Total diet study nutritional elements, 1982-1989", J Am Diet Assoc, 91, pp.179~183 (1991)
- Lee SM, "Lawrance PR. Iodine in British foods and diets", Br J Nutr, 72, pp.435~446 (1994)
- Laurberg P, "Iodine intake and the pattern of thyroid disorders: a comparative epidemiological study of thyroid abnormalities in the elderly in Iceland and in Jutland, Denmark", J Clin Endocrinol Metab, 83, pp.765~769 (1998)
- Soldin OP, "Controversies in urinary iodine determinations", Clin Biochem, 35, pp.575~579 (2002)
- Ristic-Medic D, "Methods of assessment of iodine status in humans: a systematic review", Am J Clin Nutr, 89, pp.2052S~2069S (2009)
- Rasmussen LB, "Day-to-day and withinday variation in urinary iodine excretion", Eur J Clin Nutr, 53, pp.401~407 (1999)
- Als C, "Urinary iodine concentration follows a circadian rhythm: a study with 3023 spot urine samples in adults and children", J Clin Endocrinol Metab, 85, pp.1367~1369 (2000)
- Andersen S, "Reliability of studies of iodine intake and recommendations for number of samples in groups and in individuals", Br J Nutr, 99, pp.813~818 (2008)
- Knudsen N, "A new standard in epidemiological surveys? Evaluation of three different estimates of iodine excretion based on casual urine samples and comparison to 24 h values", Eur J Clin Nutr, 54, pp.361~363 (2000)
- WHO, "Assessment of iodine deficiency disorders and monitoring their elimination: a guide for programme managers. 3rd ed" (2007), WHO
- Caldwell KL, "Urinary iodine concentration:United States National Health And Nutrition Examination Survey 2001-2002", Thyroid, 15, pp.692~699 (2005)
- 이수연, "유도결합플라즈마질량분석기를 이용한 체내 미량금속 분석", The Korean Journal of Laboratory Medicine, 24(6), pp.362~370 (2004), 대한진단검사의학회
- Hsiung CS, "Minimizing interferences in the quantitative multielement analysis of trace elements in biological fluids by inductively coupled plasma mass spectrometry", Clin Chem, 43, pp.2303~2311 (1997)
- Haldimann M, "Direct determination of urinary iodine by inductively coupled plasma mass spectrometry using isotope dilution with iodine-129", Clin Chem, 44, pp.817~824 (1998)
- Pabla D, "Development and validation of an inductively coupled plasma mass spectrometry method for quantification of levothyroxine in dissolution studies", Rapid Commun Mass Spectrom, 22, pp.993~996 (2008)
- Melichercik J, "Comparison of ion-specific electrode and high performance liquid chromatography methods for the determination of iodide in milk", J Dairy Sci, 89, pp.934~937 (2006)
- Hammer D, "Comparison of ion-selective electrode and inductively coupled plasma-mass spectrometry to determine iodine in milk-based nutritional products", J AOAC Int, 91, pp.1397~1401 (2008)
