초록

In this study, we organized the test results obtained from the performance tests for the CA certificated air cleaners which had been commercially available in Korea since 2003, and analyzed the correlation among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level etc. The noise level of 267 air cleaners were increased as concentrated at the 45, 50, 55 dB, which are the required noise level for CA certification according to flow rate, and ozone emissions from the CA air cleaners were significantly lower than the requirement limit, 50 ppb for 24 hour operation. The average particle collection efficiency and odor removal efficiency were 89.3 and 80.8%, approximately 20% higher than the requirement of CA certification, regardless of flow rates. The particle removal performance of an air cleaner was clearly discriminated by its CADR, and the CADR was obtained with a simple calculation: 0.79 x flow rate. The low differentiation of gas removal performance of air cleaners by the current CA gas test method was improved by 3.2, 751.3, 13.4times for ammonia, acetic acid, respectively, by adopting the CADR concept and the real time measurement method, FTIR, for gas removal performance test.

Abstract

In this study, we organized the test results obtained from the performance tests for the CA certificated air cleaners which had been commercially available in Korea since 2003, and analyzed the correlation among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level etc. The noise level of 267 air cleaners were increased as concentrated at the 45, 50, 55 dB, which are the required noise level for CA certification according to flow rate, and ozone emissions from the CA air cleaners were significantly lower than the requirement limit, 50 ppb for 24 hour operation. The average particle collection efficiency and odor removal efficiency were 89.3 and 80.8%, approximately 20% higher than the requirement of CA certification, regardless of flow rates. The particle removal performance of an air cleaner was clearly discriminated by its CADR, and the CADR was obtained with a simple calculation: 0.79 x flow rate. The low differentiation of gas removal performance of air cleaners by the current CA gas test method was improved by 3.2, 751.3, 13.4times for ammonia, acetic acid, respectively, by adopting the CADR concept and the real time measurement method, FTIR, for gas removal performance test.

참고문헌 (15)

  1. AHAM, "ANSI", AHAM AC-1-2006, Method for Measuring Performance of Portable Household Electric Room Air Cleaners, 2006
  2. Brown, S.K, "Concentrations of volatile organic compounds in indoor air – a review", Indoor Air, 4, pp.123~134 (1994)
  3. Burge,P.S, "Sick building syndrome", Occupational and Environmental Medicine, 61, pp.185~190 (2004)
  4. Chen, W, "Performance of air cleaners for removing multiple volatile organic compounds in indoor air", ASHRAE Transactions, 111, pp.1101~1114 (2005)
  5. EPA, "Test Method 318, Extractive FTIR method for the measurement of emissions from the mineral wool and wool fiberglass industries", US Environmental Protection Agency, ~ (1999)
  6. EPA, "Test Method 320, Measurement of vapor phase organic and inorganic emissions by extractive Fourier transform infrared (FTIR) spectroscopy", US Environmental Protection Agency, ~ (1998)
  7. Guieysse, B, "Biological treatment of indoor air for VOC removal: potential and challenges", Biotechnology Advances, 26, pp.398~410 (2008)
  8. JEMA, "JEM 1467,Air Cleaners of Household and Similar Use", Japanese Electrical Manufacturers’ Association(JEMA), ~ (1995)
  9. KACA, "SPS-KACA002-132,Room Air Cleaner Standard", Korea Air Cleaning Association(KACA), ~ (2006)
  10. 김학준, "KACA와 AHAM 실내용 공기청정기 입자 청정화 능력 시험 방법간 비교 평가", 한국실내환경학회지, 5(4), pp.298~307 (2008), 한국실내환경학회
  11. Li, F, "Control of volatile organic compounds indoors – development of an integrated mass-transfer-based model and its application", Atmospheric Environment, 41, pp.2344~2354 (2007)
  12. NIOSH, "Method 3800, Organic and inorganic gases by extractive FTIR spectrometry, NIOSH Manual of Analytical Methods, 4thEd", pp.1~47 (2002)
  13. Niu, J, "Using large environmental chamber technique for gaseous contaminant removal equipment test", ASHRAE Transactions, 104(2), pp.1289~1296 (1998)
  14. Zhang, J.J, "Indoor air pollution: a global health concern", British Medical Bulletin, 68, pp.209~225 (2003)
  15. Zuraimi, M.S, "A comparative study of VOCs in Singapore and European office buildings", Building and Environment, 41, pp.316~329 (2006)