Objectives: Bioaerosols released by treating organic-waste resources cause a variety of environmental and hygiene problems. The objective of this study was to investigate the distribution characteristics of the airborne bacteria emitted from a pig manure composting plant, a principal site for organic-waste resource facilities. Methods: Three types of pig manure composting plant were selected based on fermentation mode: screw type, rotary type and natural-dry type. Each site was visited and investigated on a monthly basis between September 2009 and August 2010. A total of 36 air samplings were obtained from the pig manure composting plants. The air sampling equipment was a six-stage cascade impactor. Quantification and qualification of airborne bacteria in the air samples was performed by agar culture method and identification technique, respectively. Results: The mean concentrations of airborne bacteria in pig manure composting plant were 7,032 (${\pm}1,496$) CFU $m^{-3}$ for screw type, 3,309 (${\pm}1,320$) CFU $m^{-3}$ for rotary type, and 5,580 (${\pm}1,106$) CFU $m^{-3}$ for natural dry type. The screw type pig manure composting plant showed the highest concentration of airborne bacteria, followed by the natural dry type and the rotary type. The ratio of respirable to total airborne bacteria was approximately 40-60%. The predominant genera of airborne bacteria identified were Micrococcus spp., Staphylococcus spp. and Escherichia spp. Conclusion: Monthly levels of airborne bacteria were highest in August and lowest in November regardless of fermentation mode. There was no significant correlation relationship between airborne bacteria and environmental factors such as temperature, relative humidity and particulate matters in pig manure composting plants.

Abstract

Objectives: Bioaerosols released by treating organic-waste resources cause a variety of environmental and hygiene problems. The objective of this study was to investigate the distribution characteristics of the airborne bacteria emitted from a pig manure composting plant, a principal site for organic-waste resource facilities. Methods: Three types of pig manure composting plant were selected based on fermentation mode: screw type, rotary type and natural-dry type. Each site was visited and investigated on a monthly basis between September 2009 and August 2010. A total of 36 air samplings were obtained from the pig manure composting plants. The air sampling equipment was a six-stage cascade impactor. Quantification and qualification of airborne bacteria in the air samples was performed by agar culture method and identification technique, respectively. Results: The mean concentrations of airborne bacteria in pig manure composting plant were 7,032 (${\pm}1,496$) CFU $m^{-3}$ for screw type, 3,309 (${\pm}1,320$) CFU $m^{-3}$ for rotary type, and 5,580 (${\pm}1,106$) CFU $m^{-3}$ for natural dry type. The screw type pig manure composting plant showed the highest concentration of airborne bacteria, followed by the natural dry type and the rotary type. The ratio of respirable to total airborne bacteria was approximately 40-60%. The predominant genera of airborne bacteria identified were Micrococcus spp., Staphylococcus spp. and Escherichia spp. Conclusion: Monthly levels of airborne bacteria were highest in August and lowest in November regardless of fermentation mode. There was no significant correlation relationship between airborne bacteria and environmental factors such as temperature, relative humidity and particulate matters in pig manure composting plants.

참고문헌 (32)

  1. Lee SH, "Analysis of the available potential volumes of waste resources energy and the policy direction in Korea", J KSWM, 28(3), pp.249~259 (2011)
  2. Fracchia L, "The assessment of airborne bacterial contamination in three composting plants revealed siterelated biological hazard and seasonal variations", J Appl Microbiol, 100, pp.973~984 (2006)
  3. Bruce JM, "Environmental aspects of respiratory disease in intensive pig and poultry houses, Including the implications for human health", Proceedings EC Meeting Aberdeen, EC Commission Publications, Brussels, 10, pp.29~30 (1987)
  4. Olson DK, "Health hazards affecting the animal confinement farm worker", Am Assoc Occup Health Nurse J, 44, pp.198~204 (1996)
  5. 4, "Mikrobiologie des Abfalls, In Keimbelastung in der Abfallwirtschaft: Tagung, 26", 1995
  6. Fischer G, "Mycotoxins of Aspergillus Fumigatus in pure culture and in native bioaerosols from compost facilities", Chemosphere, 38, pp.1745~1755 (1999)
  7. Hryhorczuk D, "Bioaerosols emission from a suburban yard waste composting facility", Ann Agric Environ Med, 8, pp.177~185 (2001)
  8. Jager E, "Composting facilities. 2. Aerogenic microorganism content at different working areas of composting facilites", Zentralbl Hyg Umweltmed, 196, pp.367~379 (1994)
  9. Reinthaler FF, "The assessment of airborne microorganisms in large-scale composting facilities and their immediate surroundings", Aerobiologia, 13, pp.167~175 (1997)
  10. Sachez-Monedero MA, "Generation and dispersion of airborne microorganisms from composting facilities", Process Saf Environ, 81, pp.166~170 (2003)
  11. Grisoli P, "Assessment of airborne microorganism contamination in an industrial area characterized by an open composting facility and wastewater treatment", Environ Res, 109, pp.135~142 (2009)
  12. Jones AM, "The effects of meteorological factors on atmospheric bioaerosol concentrations- a review", Sci Total Environ, 326, pp.151~180 (2004)
  13. Folmsbee M, "Bioaerosol concentration at an outdoor composting center", J Air Waste Manage Assoc, 49, pp.554~561 (1999)
  14. Tong Y, "Solar radiation has a lethal effect on natural populations of culturable outdoor atmospheric bacteria", Atmos Environ, 31, pp.897~900 (1997)
  15. 김기연, "서울시 일부 지하철역 내 부유 진균, 입자상 물질, 이산화탄소의 분포 양상", 예방의학회지, 39(4), pp.325~330 (2006), 대한예방의학회
  16. 이경종, "서울시 일부 지하철역 내 분포하는 부유 세균 및 입자상 오염물질 평가", 한국환경보건학회지, 32(4), pp.254~261 (2006), 한국환경보건학회
  17. 김치년, "Airborne microbiological characteristics in public buildings of Korea", BUILDING AND ENVIRONMENT, 42(5), pp.2188~2196, PERGAMON-ELSEVIER SCIENCE LTD
  18. 김기연, "일반 사무실 실내공기 내 부유미생물의 분포 양상", 한국산업위생학회지, 18(1), pp.11~19 (2008), 한국산업위생학회
  19. Kim KY, "Distribution characteristics of airborne bacteria and fungi in the feedstuff-manufacturing factories", J Hazard Mat, 169, pp.1054~1060 (2009)
  20. Kim KY, "Assessment of airborne bacteria and fungi in pig buildings in Korea", Biosys Eng, 99, pp.565~572 (2008)
  21. Byeon JH, "Size distributions of total airborne particles and bioaerosols in a municipal composting facility", Bioresour Technol, 99, pp.5150~5154 (2008)
  22. 이철민, "다중이용시설내 공기중 바이오에어로졸 농도분포 특성에 관한 연구", 한국환경과학회지, 13(3), pp.215~222 (2004), 한국환경과학회
  23. Kim KY, "Distribution characteristics of airborne bacteria and fungi in the general hospitals of Korea", Ind Health, 48, pp.236~243 (2010)
  24. Marthi B, "Effects of betaine on the enumeration of airborne bacteria", Appl Environ Microbiol, 56, pp.1286~1289 (1990)
  25. Walter MV, "Effect of aerosolization on subsequent bacterial survival", Appl Environ Microbiol, 56, pp.3468~3472 (1990)
  26. Macher JM, "A two-year study of microbiological indoor air quality in a newapartment", Arch Environ Health, 46, pp.25~29 (1991)
  27. Li CS, "Home dampness and childhood respiratory symptoms in a subtropical climate", Arch Environ Health, 51, pp.42~46 (1996)
  28. 김치년, "Temporal and spatial distributions of aerial contaminants in an enclosed pig building in winter", ENVIRONMENTAL RESEARCH, 99, pp.150~157, ACADEMIC PRESS INC ELSEVIER SCIENCE
  29. DeKoster JA, "Bioaerosol concentrations in noncomplaint, complaint and intervention homes in the Midwest", Am Ind Hyg Assoc J, 56, pp.576~580 (1995)
  30. Gorny RL, "Size distribution of bacterial and fungal bioaerosols in indoor air", Ann Agric Environ Med, 6, pp.105~113 (1999)
  31. Pastuszka JS, "Bacterial and fungal aerosol in indoor environment in Upper Silesia, Poland", Atmos Environ, 34, pp.3833~3842 (2000)
  32. Gorny RL, "Size distribution of bacterial and fungal bioaerosols in indoor air", Ann Agric Environ Med, 6, pp.105~113 (1999)

관련 논문AI추천

이 간행물의 다른 논문 (9건)