Objective: A concentration of airborne bacteria generated from swine houses is recognized to be relatively higher than other work places and it is essential to optimally manage it to prevent farmers’ respiratory diseases. This study was conducted to assess the distribution characteristics of airborne bacteria in swine houses located at South Korea. Methods: A total 27 pig buildings of the enclosed type operated with mechanical ventilation system by a side wall fan and deep-pit manure system with slats were surveyed. Air samples were collected at 1.0 m above the middle floor in pig housing room. A six-stage viable particulate cascade impactor was used to identify the distribution of the sizes of particles in diameter. Results: Seasonal mean levels of airborne bacteria in the housing rooms of gestation/farrowing pigs, nursery pigs and growing/fattening pigs were 3,428(±1,244) colony forming unit (cfu)/m3, 8,325(±3,209) cfu/m, and 13,254(±6,108) cfu/m3 for spring; 9,824(±2,157) cfu/m3, 18,254(±5,166) cfu/m3, and 24,088(±9,274) cfu/m3 for summer; 1,707(±957) cfu/m3, 4,258 (±1,438) cfu/m3, and 8,254(±2,416) cfu/m3 for autumn; and 2,322(±1,352) cfu/m3, 6,124(±1,527) cfu/m3 and 12,470(±4,869) cfu/m3 for winter, respectively. Conclusion: Concentrations of airborne bacteria according to pig housing type were highest in growing/fattening housing room followed by nursery housing room and gestation/farrowing housing room. In terms of seasonal aspect, the pig building showed the highest levels of airborne bacteria in summer followed by spring, winter and autumn. The respirable airborne bacteria which are ranged between 0.6 and 4.7 μm accounted for approximately 60% compared to total airborne bacteria regardless of pig housing type.

Abstract

Objective: A concentration of airborne bacteria generated from swine houses is recognized to be relatively higher than other work places and it is essential to optimally manage it to prevent farmers’ respiratory diseases. This study was conducted to assess the distribution characteristics of airborne bacteria in swine houses located at South Korea. Methods: A total 27 pig buildings of the enclosed type operated with mechanical ventilation system by a side wall fan and deep-pit manure system with slats were surveyed. Air samples were collected at 1.0 m above the middle floor in pig housing room. A six-stage viable particulate cascade impactor was used to identify the distribution of the sizes of particles in diameter. Results: Seasonal mean levels of airborne bacteria in the housing rooms of gestation/farrowing pigs, nursery pigs and growing/fattening pigs were 3,428(±1,244) colony forming unit (cfu)/m3, 8,325(±3,209) cfu/m, and 13,254(±6,108) cfu/m3 for spring; 9,824(±2,157) cfu/m3, 18,254(±5,166) cfu/m3, and 24,088(±9,274) cfu/m3 for summer; 1,707(±957) cfu/m3, 4,258 (±1,438) cfu/m3, and 8,254(±2,416) cfu/m3 for autumn; and 2,322(±1,352) cfu/m3, 6,124(±1,527) cfu/m3 and 12,470(±4,869) cfu/m3 for winter, respectively. Conclusion: Concentrations of airborne bacteria according to pig housing type were highest in growing/fattening housing room followed by nursery housing room and gestation/farrowing housing room. In terms of seasonal aspect, the pig building showed the highest levels of airborne bacteria in summer followed by spring, winter and autumn. The respirable airborne bacteria which are ranged between 0.6 and 4.7 μm accounted for approximately 60% compared to total airborne bacteria regardless of pig housing type.

참고문헌 (24)

  1. Aarnink AJA, "Effect of slatted floor area on ammonia emission and on the excretory and lying behavior of growing pigs", J Agric Eng Res, 64, pp.299~310 (1996)
  2. Conference Thando Mpendulo, "Effect of fibrous diets on chemical composition and odours from pig slurry", Animal Bioscience, 31(11), pp.1833~1839 (2018), 아세아·태평양축산학회[DOI]
  3. Chang CW, "Exposure assessment to airborne endotoxin, dust, ammonia, hydrogen sulfide and carbon dioxide in open style swine houses", Ann Occup Hyg, 45, pp.457~465 (2001)
  4. Crook B, "Airborne dust, ammonia, microorganisms, and antigens in pig confinement houses and the respiratory health of exposed farm workers", Am Ind Hyg Assoc J, 52, pp.271~279 (1991)
  5. Donham KJ, "Preventing respiratory disease in swine confinement workers : intervention through applied epidemiology, education, and consultation", Am J Ind Med, 18, pp.241~261 (1990)
  6. Whyte RT, "Aerial pollutants and the health of poultry farmers", World's Poult Sci J, 49, pp.139~156 (1993)
  7. Pearson CC, "Airborne dust concentrations in livestock buildings and the effect of feed", J Agric Eng Res, 60, pp.145~154 (1995)
  8. Olson DK, "Health hazards affecting the animal confinement farm worker", Am Assoc Occup Health Nur J, 44, pp.198~204 (1996)
  9. Clark S, "Airborne bacteria, endotoxin and fungi in dust in poultry and swine confinement buildings", Am Ind Hyg Assoc J, 44, pp.537~541 (1983)
  10. Griffiths WD, "Assessment of bioaerosols : a critical review", J Aerosol Sci, 25, pp.1425~1458 (1994)
  11. Duchaine C, "Influence of building maintenance, environmental factors, and seasons on airborne contaminants of swine confinement buildings", Am Ind Hyg Assoc J, 61, pp.56~63 (2000)
  12. Seedorf J, "Concentrations and emissions of airborne endotoxins and microorganisms in livestock buildings in Northern Europe", J Agric Eng Res, 70, pp.97~109 (1998)
  13. Elliott LF, "Bacteria in the air of housed swine units", Appl Environ Microbiol, 32, pp.270~273 (1976)
  14. Cormier Y, "Airborne microbial contents in two types of swine confinement buildings in Quebec", Am Ind Hyg Assoc J, 51, pp.304~309 (1990)
  15. Heederik D, "Relationship of airborne endotoxins and bacteria levels in pig farms with the lung function and respiratory symptoms of farmers", Int Arch Occup Environ Health, 62, pp.595~601 (1991)
  16. Thorne PS, "Comparison of bioaerosol sampling methods in barns housing swine", Appl Environ Microbiol, 58, pp.2543~2551 (1992)
  17. Nicks B, "Air pollution levels in pig houses", ASAE (1993)
  18. Dutkiewicz J, "Airborne microorganisms and endotoxin in animal houses", Grana, 33, pp.85~90 (1994)
  19. Predicala BZ, "Assessment of bioaerosols in swine barns by filtration and impaction", Curr Microbiol, 44, pp.136~140 (2002)
  20. Kim KY, "Assessment of airborne bacteria and fungi in pig buildings in Korea", Biosyst Eng, 99, pp.565~572 (2008)
  21. 김윤신, "다중이용시설에서의 실내공기 중 미생물 분포에 관한 연구", 한국환경보건학회지, 28(1), pp.85~92 (2002), 한국환경보건학회
  22. 이창래, "종합병원내 부유 미생물 농도 및 환경 요인과의 상관성 조사", 한국산업보건학회지, 15(1), pp.45~51 (2005), 한국산업보건학회
  23. 박재범, "다중이용시설 내부에 분포하는 부유 진균의 입경별 농도 특성", 한국환경보건학회지, 32(1), pp.36~45 (2006), 한국환경보건학회
  24. 김기연, "사료제조공장 내 공기 중 세균과 진균 분포에 관한 연구", 한국산업보건학회지, 17(4), pp.335~342 (2007), 한국산업보건학회

관련 논문AI추천

이 간행물의 다른 논문 (5건)