본문 바로가기
KERD
논문KCI 등재

과전류 조건에 따른 단열 다심관의 수냉각 성능 분석

Analysis of Water Cooling Performance of Insulated Multi-Core Tube Under Overcurrent Condition

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류기계공학

초록

Recently, the International Maritime Organization is strengthening regulations for ships operating in polar regions. Hence, insulated multi-core tubes as components for vessels operating in extreme cold need to be investigated in various aspects. Furthermore, the demand for research on electric propulsion vessels is also increasingly growing. Thus, to utilize a 4-core insulated multi-core tube with glass wool as insulation, which was previously developed for ships operating in polar regions, as a water-cooled electrical cable, this study conducted an experiment on the temperature change when water at normal temperature 25℃ was supplied as a coolant under the overcurrent varied from 10A to 25A. As a result, the temperature increase of the core in 10A condition was 3.3℃, but it increased to 13.05℃ in the 25A condition. This showed that a temperature difference of approximately 9.75℃ occurred according to the overcurrent load. However, the coolant inlet and outlet temperatures were relatively uniform around 1℃ in all conditions. This suggests that increasing the residence time by proper control of the coolant flow in the future could achieve a higher cooling effect.

Abstract

Recently, the International Maritime Organization is strengthening regulations for ships operating in polar regions. Hence, insulated multi-core tubes as components for vessels operating in extreme cold need to be investigated in various aspects. Furthermore, the demand for research on electric propulsion vessels is also increasingly growing. Thus, to utilize a 4-core insulated multi-core tube with glass wool as insulation, which was previously developed for ships operating in polar regions, as a water-cooled electrical cable, this study conducted an experiment on the temperature change when water at normal temperature 25℃ was supplied as a coolant under the overcurrent varied from 10A to 25A. As a result, the temperature increase of the core in 10A condition was 3.3℃, but it increased to 13.05℃ in the 25A condition. This showed that a temperature difference of approximately 9.75℃ occurred according to the overcurrent load. However, the coolant inlet and outlet temperatures were relatively uniform around 1℃ in all conditions. This suggests that increasing the residence time by proper control of the coolant flow in the future could achieve a higher cooling effect.

참고문헌 (12)

  1. 이태호, "글라스울을 단열재로 활용한 멀티코어튜브의 단열 성능 분석 및 실험에 관한 연구", 수산해양교육연구, 31(3), pp.756~764 (2019), 한국수산해양교육학회[DOI]
  2. T. H. Lee, "A Study on the Heat Transfer Characteristic of Insulated Multi Core Tube", Master, pp.2016
  3. 정성엽, "극지운항용 선박에 적용되는 방한기술 동향 분석", 대한조선학회 논문집, 56(2), pp.135~142 (2019), 대한조선학회[DOI]
  4. Development of Thermal Insulation multi core tube for extreme region with Glass wool, "M. J. Kim", Industrial-Academic Cooperation at Kunsan National University, ~ (2017)
  5. 권동준, "조선해양 파이프 단열재 커버 적용을 위한 내화", 난연 성능을 갖는 친환경 바잘트섬유 강화 퓨란계 복합재료 개발 연구, 2021, pp.34(1), 57~62[DOI]
  6. M. S. Choi, "Development of Multi Core Tube having Flame Retardant Performance", Proceedings of the Korea Institute of Fire Science and Engineering Conference, pp.46~52 (2002)
  7. 안지호, "충진재의 열전도도 변화에 따른 수냉각 고전류 충전 케이블의 방열특성에 대한 수치해석", 대한기계학회논문집 B, 43(5), pp.361~370 (2019), 대한기계학회
  8. 박진영, "과전류에 의해 단락된 전선의 결정성장 특성에 관한 연구", 한국화재소방학회 논문지, 31(6), pp.83~90 (2017), 한국화재소방학회[DOI]
  9. Development of a ship's multi-core tube with high-functional film plated by macroamulsion, "Y. H. Kim", Korea Maritime and Ocean University, ~ (2009)
  10. Development of Eco-friendly Substitute for Ship asbestos, "Glassoul Insulation", S. Y. Kim, 2013
  11. 박상균, "단열 다심관의 열전달 특성에 관한 연구", 한국마린엔지니어링학회지, 39(6), pp.604~608 (2015), 한국마린엔지니어링학회[DOI]
  12. KESCO, "The Fire Investigation for the Ignition Position and the Collection Guide of a Hangover (A Cause Analysis and Judgment for the Overcurrent Fire)", Korea Electrical Safety Corporation, 6~ (2006)

관련 논문AI추천

이 간행물의 다른 논문 (45건)