본문 바로가기
KERD
논문KCI 등재

대잠용 수온측정계 측정 메커니즘 개선

An Improvement of Expendable Bathythermograph Measurement Mechanism for Anti-Submarine Warfare

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류학제간연구

초록

Purpose: The purpose of this study is to improve a mechanism of expendable bathythermograph measurement by balancing wire resistances between plus wire part and minus wire part and by removing effects of seawater resistance between XBT(Expendable Bathythermograph) and temperature recorder. Methods: The problems are exactly found out through the analysis of XBT and temperature recorder circuit. A process of XBT manufacturing that balances wire resistances between plus wire part and minus wire part is added. Results: The results of this study are as follows; the complicated test process such as temperature accuracy test with a cistern is substituted with a simple process of XBT manufacturing such as balancing wire resistances between plus wire part and minus wire part. Then, the temperature accuracy tolerance of XBT is improved up to ±0.1℃. Conclusion: Consequently, balancing wire resistances and removing effects of sea water resistance improve temperature accuracy of XBT and reduce expensive and harassing process of XBT manufacturing.

Abstract

Purpose: The purpose of this study is to improve a mechanism of expendable bathythermograph measurement by balancing wire resistances between plus wire part and minus wire part and by removing effects of seawater resistance between XBT(Expendable Bathythermograph) and temperature recorder. Methods: The problems are exactly found out through the analysis of XBT and temperature recorder circuit. A process of XBT manufacturing that balances wire resistances between plus wire part and minus wire part is added. Results: The results of this study are as follows; the complicated test process such as temperature accuracy test with a cistern is substituted with a simple process of XBT manufacturing such as balancing wire resistances between plus wire part and minus wire part. Then, the temperature accuracy tolerance of XBT is improved up to ±0.1℃. Conclusion: Consequently, balancing wire resistances and removing effects of sea water resistance improve temperature accuracy of XBT and reduce expensive and harassing process of XBT manufacturing.

참고문헌 (5)

  1. Albert, David., "Electronic Principles, 7th Edi" (2006), Mcgraw-Hill
  2. Donald, Ross. W., "Mechanics of Underwater Noise" (1987), Peninsula Publishing
  3. James, W. N., "Electric circuits, 9th Edi" (2010), Pearson
  4. Kim, D. Y., "Sea and Defence Technology", The Korean Physical Society, 15, pp.25~30 (2006)
  5. Waite, A. D., "Sonar for Practising Engineers" (2002), John Wiley & Sons

관련 논문AI추천

이 간행물의 다른 논문 (16건)