초록

A vaporizer is a device for vaporizing cryogenic liquids such as liquefied natural gas (LNG) using a high-temperature heat source. Among the various types of vaporizers, the ambient air vaporizer (AAV) uses air in the atmosphere as the heat exchange medium; therefore, it is regarded as an eco-friendly heat exchanger. However, owing to the fuzziness and frost formed on the surface of the AAV, the vaporization efficiency decreases. In this study, the frost generation and formation on AAVs were investigated. For evaluation of the AAV performance, the outlet temperature of the LNG and the thickness of the frost layer formed were observed for different numbers of fins and effects of different seasons. Finally, these were also measured considering different convective heat transfer coefficients to observe the effect of different convective conditions; in this case, the outlet temperature of the LNG was not influenced by different seasons. However, the frost thickness was found to be affected by different seasons.

Abstract

A vaporizer is a device for vaporizing cryogenic liquids such as liquefied natural gas (LNG) using a high-temperature heat source. Among the various types of vaporizers, the ambient air vaporizer (AAV) uses air in the atmosphere as the heat exchange medium; therefore, it is regarded as an eco-friendly heat exchanger. However, owing to the fuzziness and frost formed on the surface of the AAV, the vaporization efficiency decreases. In this study, the frost generation and formation on AAVs were investigated. For evaluation of the AAV performance, the outlet temperature of the LNG and the thickness of the frost layer formed were observed for different numbers of fins and effects of different seasons. Finally, these were also measured considering different convective heat transfer coefficients to observe the effect of different convective conditions; in this case, the outlet temperature of the LNG was not influenced by different seasons. However, the frost thickness was found to be affected by different seasons.

참고문헌 (9)

  1. N. J. Kim, "A Study on boiling characteristics of direct contact LNG evaporator", Proceedings of the Society of Air-conditioning and Refrigerating Engineers of Korea, pp.380~385 (1994)
  2. Y. Lee, "Modeling and analysis of frost growth in pilot-scale ambient air vaporizer", Industrial &Engineering Chemistry Research, 57(17), pp.5933~5943 (2018)
  3. 김필환, "초저온 액화가스 기화기의 열 교환성능 비교에 관한 연구", 설비공학 논문집, 20(10), pp.679~688 (2008), 대한설비공학회
  4. 박상균, "공조용 열교환기 증발관에서의 서리 발생에 관한 메커니즘의 실험적 연구", 한국항해항만학회지, 30(1), pp.113~117 (2006), 한국항해항만학회
  5. C. J. L. Hermes, "A study of frost growth and densification on flat surfaces", Experimental Thermal and Fluid Science, 33(2), pp.371~379 (2009)
  6. 박우창, "A60급 구획 적용 격벽 관통용 관의 열전달 특성 I: 관의 설계에 따른 과도 열해석", 한국해양공학회지, 32(5), pp.310~323 (2018), 한국해양공학회[DOI]
  7. 박우창, "A60급 구획 적용 격벽 관통용 관의 열전달 특성 II: 관 재질 및 단열재 종류에 따른 방화시험", 한국해양공학회지, 33(4), pp.340~349 (2019), 한국해양공학회[DOI]
  8. 김지혜, "2차원 쐐기형 몰수체의 비정상 공동 와류에 대한 수치해석", 한국해양공학회지, 32(1), pp.36~42 (2018), 한국해양공학회
  9. S. Liu, "Three-dimensional numerical analysis of the coupled heat transfer performance of LNG ambient air vaporizer", Renewable Energy, 87(part 3), pp.1105~1112 (2016)

관련 논문AI추천