본문 바로가기
KERD
논문

Fin and Temperature Effect of Frost in Ambient Air Vaporizer

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류해양공학

초록

Since liquefied natural gas (LNG) is imported in a liquid state of about -162℃ to increase transportation efficiency in Korea, it must be vaporized in a gaseous state to supply it to consumers. Among them, ambient air vaporizer (AAV) has caught attention due to eco-friendly and low costs characteristics. However, there is a disadvantage that the performance of the heat exchanger is deteriorated due to frost due to mist and icing when used for a long time. In this paper, frost generation model in AAV vaporizer was investigated with numerically to examine utilizing the vaporizer performance with the frost generation behavior. The frost generation behavior of AAV vaporizers was examined with humidity, fin characteristic, and temperature effects. As for the LNG discharge temperature, the 12 fin vaporizer showed the highest discharge temperature when the atmospheric temperature was 25℃, and the 8 fin vaporizer had the lowest LNG discharge temperature when the atmospheric temperature was 0℃. In the case of frost formation, in the case of the 12 fin vaporizer, it was formed the most at the atmospheric temperature of 25℃, and the least was formed in the vaporizer at the 0℃ condition of the atmospheric temperature of 8 fins.

Abstract

Since liquefied natural gas (LNG) is imported in a liquid state of about -162℃ to increase transportation efficiency in Korea, it must be vaporized in a gaseous state to supply it to consumers. Among them, ambient air vaporizer (AAV) has caught attention due to eco-friendly and low costs characteristics. However, there is a disadvantage that the performance of the heat exchanger is deteriorated due to frost due to mist and icing when used for a long time. In this paper, frost generation model in AAV vaporizer was investigated with numerically to examine utilizing the vaporizer performance with the frost generation behavior. The frost generation behavior of AAV vaporizers was examined with humidity, fin characteristic, and temperature effects. As for the LNG discharge temperature, the 12 fin vaporizer showed the highest discharge temperature when the atmospheric temperature was 25℃, and the 8 fin vaporizer had the lowest LNG discharge temperature when the atmospheric temperature was 0℃. In the case of frost formation, in the case of the 12 fin vaporizer, it was formed the most at the atmospheric temperature of 25℃, and the least was formed in the vaporizer at the 0℃ condition of the atmospheric temperature of 8 fins.

참고문헌 (13)

  1. Afrasiabian, E, "Numerical Simulation of Frost Formation on a Plate-Fin Evaporator", Proceedings of the 3rd World Congress on Momentum, Heat and Mass Transfer (MHMT'18) Budapest (2018)
  2. Fernández, I. A, "Review of Propulsion Systems on LNG Carriers", Renewable and Sustainable Energy Reviews, 67, pp.1395~1411 (2017)[DOI]
  3. Hermes, C. J. L, "A Study of Frost Growth and Densification on Flat Surfaces", Experimental Thermal and Fluid Science, 33(2), pp.371~379 (2009)[DOI]
  4. 김지혜, "2차원 쐐기형 몰수체의 비정상 공동 와류에 대한 수치해석", 한국해양공학회지, 32(1), pp.36~42 (2018), 한국해양공학회
  5. Kim, N. J, "A Study on Boiling Characteristics of Direct Contact LNG Evaporator", Proceedings of the Society of Air-Conditioning and Refrigerating Engineers of Korea, pp.380~385 (1994)
  6. 김필환, "초저온 액화가스 기화기의 열 교환성능 비교에 관한 연구", 설비공학 논문집, 20(10), pp.679~688 (2008), 대한설비공학회
  7. Lee, Y. K, "Robust Design of Ambient-Air Vaporizer Based on Time-Series Clustering", Computers & Chemical Engineering, 118, pp.236~247 (2018)[DOI]
  8. Lee, Y. K, "Modeling and Analysis of Frost Growth in Pilot-Scale Ambient Air Vaporizer", Industrial & Engineering Chemistry Research, 57(17), pp.5933~5943 (2018)[DOI]
  9. 박상균, "공조용 열교환기 증발관에서의 서리 발생에 관한 메커니즘의 실험적 연구", 한국항해항만학회지, 30(1), pp.113~117 (2006), 한국항해항만학회
  10. 박우창, "A60급 구획 적용 격벽 관통용 관의 열전달 특성 II: 관 재질 및 단열재 종류에 따른 방화시험", 한국해양공학회지, 33(4), pp.340~349 (2019), 한국해양공학회[DOI]
  11. 박우창, "A60급 구획 적용 격벽 관통용 관의 열전달 특성 I: 관의 설계에 따른 과도 열해석", 한국해양공학회지, 32(5), pp.310~323 (2018), 한국해양공학회[DOI]
  12. Querol, E, "Boil offGas(BOG)Management in Spanishliquid Natural Gas(LNG)Terminals", Appled Energy, 87(11), pp.3384~3392 (2010)[DOI]
  13. Rao, H. N, "Minimizing Power Consumption Related to BOG Reliquefactionin an LNG Regasification Terminal", Industrial & Engineering Chemistry Research, 55(27), pp.7431~7445 (2016)[DOI]

관련 논문AI추천