Dual-Toehold-Probe-Mediated Exonuclease-III-Assisted Signal Recycles Integrated with CHA for Detection of mecA Gene Using a Personal Glucose Meter in Skin and Soft Tissue Infection
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Staphylococcus aureus integrated with mecA gene, which codes for penicillin-binding protein 2a, is resistant to all penicillins and other beta-lactam antibiotics, resulting in poor treatment expectations in skin and soft tissue infections. The development of a simple, sensitive and portable biosensor for mecA gene analysis in S. aureus is urgently needed. Herein, we propose a dual-toehold-probe (sensing probe)-mediated exonuclease-III (Exo-III)-assisted signal recycling for portable detection of the mecA gene in S. aureus. When the target mecA gene is present, it hybridizes with the sensing probe, initiating Exo III-assisted dual signal recycles, which in turn release numerous “3” sequences. The released “3” sequences initiate catalytic hairpin amplification, resulting in the fixation of a sucrase-labeled H2 probe on the surface of magnetic beads (MBs). After magnet-based enrichment of an MB-H1-H2-sucrase complex and removal of a liquid supernatant containing free sucrase, the complex is then used to catalyze sucrose to glucose, which can be quantitatively detected by a personal glucose meter. With a limit of detection of 4.36 fM for mecA gene, the developed strategy exhibits high sensitivity. In addition, good selectivity and anti-interference capability were also attained with this method, making it promising for antibiotic tolerance analysis at the point-of-care.
Abstract
Staphylococcus aureus integrated with mecA gene, which codes for penicillin-binding protein 2a, is resistant to all penicillins and other beta-lactam antibiotics, resulting in poor treatment expectations in skin and soft tissue infections. The development of a simple, sensitive and portable biosensor for mecA gene analysis in S. aureus is urgently needed. Herein, we propose a dual-toehold-probe (sensing probe)-mediated exonuclease-III (Exo-III)-assisted signal recycling for portable detection of the mecA gene in S. aureus. When the target mecA gene is present, it hybridizes with the sensing probe, initiating Exo III-assisted dual signal recycles, which in turn release numerous “3” sequences. The released “3” sequences initiate catalytic hairpin amplification, resulting in the fixation of a sucrase-labeled H2 probe on the surface of magnetic beads (MBs). After magnet-based enrichment of an MB-H1-H2-sucrase complex and removal of a liquid supernatant containing free sucrase, the complex is then used to catalyze sucrose to glucose, which can be quantitatively detected by a personal glucose meter. With a limit of detection of 4.36 fM for mecA gene, the developed strategy exhibits high sensitivity. In addition, good selectivity and anti-interference capability were also attained with this method, making it promising for antibiotic tolerance analysis at the point-of-care.
참고문헌 (22)
- Callejo-Torre F, "Risk factors for methicillin-resistant Staphylococcus aureus colonisation or infection in intensive care units and their reliability for predicting MRSA on ICU admission", Infez. Med, 24, pp.201~209 (2016)
- Chalmers SJ, "Methicillin-resistant Staphylococcus aureus infection and treatment options", Methods Mol. Biol, 2069, pp.229~251 (2020)
- David MZ, "Community-associated methicillin-resistant Staphylococcus aureus: epidemiology and clinical consequences of an emerging epidemic", Clin. Microbiol. Rev, 23, pp.616~687 (2010)
- Lakhundi S, "Methicillin-resistant Staphylococcus aureus: molecular characterization, evolution, and epidemiology", Clin. Microbiol. Rev, 31, pp.e00020-18~ (2018)
- Zhan XY, "Evolution of methicillin-resistant Staphylococcus aureus: Evidence of positive selection in a penicillinbinding protein (PBP) 2a coding gene mecA", Infect. Genet. Evol, 59, pp.16~22 (2018)
- Chambers HF, "Methicillin-resistant Staphylococcus aureus. mechanisms of resistance and implications for treatment", Postgrad. Med, 109, pp.43~50 (2001)
- Jabbour JF, "Treatment of multidrug-resistant Gram-negative skin and soft tissue infections", Curr. Opin. Infect. Dis, 33, pp.146~154 (2020)
- Moffarah AS, "Skin and soft tissue infections", Microbiol. Spectr, 4 (2016)[DOI]
- Chen W, "Recent advances in aptasensors for rapid and sensitive detection of Staphylococcus aureus", Front. Bioeng. Biotechnol, 10, pp.889431~ (2022)
- Rajapaksha P, "A review of methods for the detection of pathogenic microorganisms", Analyst, 144, pp.396~411 (2019)
- Melo AM, "Electrochemical immunosensors for Salmonella detection in food", Appl. Microbiol. Biotechnol, 100, pp.5301~5312 (2016)
- Heining L, "Immunomagnetic separation coupled with flow cytometry for the analysis of Legionella pneumophila in aerosols", Anal. Bioanal. Chem, 415, pp.5139~5149 (2023)
- Nouri A, "Designing a direct ELISA kit for the detection of Staphylococcus aureus enterotoxin A in raw milk samples", Int. J. Biol. Macromol, 107, pp.1732~1737 (2018)
- Olcu M, "Development of multiplex PCR panel for detection of anaerobic bacteria in clinical samples", Anaerobe, 76, pp.102611~ (2022)
- Huang T, "Rapid and simultaneous detection of five, viable, foodborne pathogenic bacteria by photoinduced PMAxx-coupled multiplex PCR in fresh juice", Foodborne Pathog. Dis, 18, pp.640~646 (2021)
- Vaillant JJ, "Antibiotic susceptibility testing of Staphylococcus aureus using the Biolog OmniLog(R)system, a metabolic phenotyping assay", Diagn. Microbiol. Infect. Dis, 104, pp.115759~ (2022)
- Gill AAS, "Nanomaterial-based optical and electrochemical techniques for detection of methicillin-resistant Staphylococcus aureus: a review", Mikrochim. Acta, 186, pp.114~ (2019)
- Wang Y, "Fluorescence detection of Staphylococcus aureus using vancomycin functionalized magnetic beads combined with rolling circle amplification in fruit juice", Anal. Chim Acta, 1189, pp.339213~ (2022)
- He Y, "Pulsed-field gel electrophoresis typing of Staphylococcus aureus strains", Methods Mol. Biol, 2069, pp.79~88 (2020)
- Weng X, "Sensitive and portable detection of bacteria using Exonuclease-III (Exo-III) assisted signal amplification and personal glucose meters", Mol. Biotechnol, 65, pp.934~941 (2023)
- Zheng L, "Rapid detection and antimicrobial susceptibility testing of pathogens using AgNPs-invertase complexes and the personal glucose meter", Front. Bioeng. Biotechnol, 9, pp.795415~ (2021)
- Yang Y, "Portable detection of Staphylococcus aureus using personal glucose meter based on hybridization chain reaction strategy", Talanta, 226, pp.122132~ (2021)
