초록
Staphylococcus aureus (S. aureus, SA) is one of the most common bacteria in nosocomial infections. Sensitive and efficient analysis of methicillin-resistance of SA is crucial for improving the nursing performance of pneumonia. However, methicillin-resistance analysis with favorable sensitivity and specificity in an enzyme-free manner remains a huge challenge. This paper presents the development of a new fluorescent biosensor for detecting mecA gene using a triple-branch catalytic hairpin assembly (CHA) triggered DNAzyme switch-based DNA tweezer. The SA from the samples are immobilized on the plate’s surface using the protein A antibody. The biosensor possesses several key features. Firstly, it utilizes dual signal amplification processes, specifically the triple-branch CHA and DNAzyme controlled DNA tweezer-based signal recycling, to enable mecA detection on the plate. This design enhances the method’s sensitivity, resulting in a low limit of detection of 1.5 fM. Secondly, the biosensor does not rely on enzymes for mecA analysis, ensuring a high level of stability during target analysis. Lastly, the method demonstrates a remarkable selectivity by accurately distinguishing target sequences from non-target sequences. The proposed biosensor, which does not require enzymes and has a high level of sensitivity, offers a viable platform for the rapid and simple quantification of mecA in SA.
Abstract
Staphylococcus aureus (S. aureus, SA) is one of the most common bacteria in nosocomial infections. Sensitive and efficient analysis of methicillin-resistance of SA is crucial for improving the nursing performance of pneumonia. However, methicillin-resistance analysis with favorable sensitivity and specificity in an enzyme-free manner remains a huge challenge. This paper presents the development of a new fluorescent biosensor for detecting mecA gene using a triple-branch catalytic hairpin assembly (CHA) triggered DNAzyme switch-based DNA tweezer. The SA from the samples are immobilized on the plate’s surface using the protein A antibody. The biosensor possesses several key features. Firstly, it utilizes dual signal amplification processes, specifically the triple-branch CHA and DNAzyme controlled DNA tweezer-based signal recycling, to enable mecA detection on the plate. This design enhances the method’s sensitivity, resulting in a low limit of detection of 1.5 fM. Secondly, the biosensor does not rely on enzymes for mecA analysis, ensuring a high level of stability during target analysis. Lastly, the method demonstrates a remarkable selectivity by accurately distinguishing target sequences from non-target sequences. The proposed biosensor, which does not require enzymes and has a high level of sensitivity, offers a viable platform for the rapid and simple quantification of mecA in SA.
참고문헌 (22)
- Ahmad-Mansour N, "Staphylococcus aureus toxins : an update on their pathogenic properties and potential treatments", Toxins(Basel), 13, pp.677~ (2021)
- Chalmers SJ, "Methicillin-resistant Staphylococcus aureus infection and treatment options", Methods Mol. Biol, 2069, pp.229~251 (2020)
- Parker D, "Immunopathogenesis of Staphylococcus aureus pulmonary infection", Semin. Immunopathol, 34, pp.281~297 (2012)
- Bassetti M, "Current pharmacotherapy for methicillin-resistant Staphylococcus aureus(MRSA)pneumonia", Expert Opin. Pharmacother, 23, pp.361~375 (2022)
- Dangerfield B, "Predictive value of methicillin-resistant Staphylococcus aureus(MRSA)nasal swab PCR assay for MRSA pneumonia", Antimicrob. Agents Chemother, 58, pp.859~864 (2014)
- He H, "Staphylococcus aureus pneumonia in the community", Semin. Respir. Crit. Care Med, 41, pp.470~479 (2020)
- Guo Y, "Prevalence and therapies of antibiotic-resistance in Staphylococcus aureus", Front. Cell. Infect. Microbiol, 10, pp.107~ (2020)
- Lee AS, "Methicillin-resistant Staphylococcus aureus", Nat. Rev. Dis. Primers, 4, pp.18033~ (2018)
- Peacock SJ, "Mechanisms of methicillin resistance in Staphylococcus aureus", Annu. Rev. Biochem, 84, pp.577~601 (2015)
- Choe H, "Detection of mecA and 16S rRNA genes using real-time PCR can be useful in diagnosing iliopsoas abscess, especially in culture-negative cases : RT-PCR for iliopsoas abscess", Biomed Res. Int, 2022, pp.2209609~ (2022)
- Fueller J, "CRISPR-Cas12a-assisted PCR tagging of mammalian genes", J. Cell Biol, 219, pp.e201910210~ (2020)
- Han HW, "Identification of Staphylococcus spp. and detection of mecA by an oligonucleotide array", Diagn. Microbiol. Infect. Dis, 86, pp.23~29 (2016)
- Monecke S, "Rapid microarray-based identification of different mecA alleles in Staphylococci", Antimicrob. Agents Chemother, 56, pp.5547~5554 (2012)
- Jet T, "Advances in multiplexed techniques for the detection and quantification of microRNAs", Chem. Soc. Rev, 50, pp.4141~4161 (2021)
- Li Q, "Ultrasensitive and simple fluorescence biosensor for detection of the mecA gene of Staphylococcus aureus by using an exonuclease III-assisted cascade signal amplification strategy", Analyst, 143, pp.5670~5675 (2018)
- Lin Q, "Direct bacterial loop-mediated isothermal amplification detection on the pathogenic features of the nosocomial pathogen-Methicillin resistant Staphylococcus aureus strains with respiratory origins", Microb. Pathog, 109, pp.183~188 (2017)
- Pan J, "A hairpin probe-mediated DNA circuit for the detection of the mecA gene of Staphylococcus aureus based on exonuclease III and DNAzyme-mediated signal amplification", Analyst, 146, pp.3673~3678 (2021)
- Weng X, "Sensitive and portable detection of bacteria using exonuclease-III(Exo-III)assisted signal amplification and personal glucose meters", Mol. Biotechnol, 65, pp.934~941 (2023)
- Chen H, "Switchable DNA tweezer and G-quadruplex nanostructures for ultrasensitive voltammetric determination of the K-ras gene fragment", Mikrochim. Acta, 186, pp.843~ (2019)
- Chen R, "Simple and programmed three-dimensional DNA tweezer for simultaneous one-step detection of ochratoxin A and zearalenone", Spectrochim. Acta A Mol. Biomol. Spectrosc, 272, pp.120991~ (2022)
- Li J, "Programmable DNA tweezer-actuated SERS probe for the sensitive Detection of AFB(1)", Anal. Chem, 92, pp.4900~4907 (2020)
- Yao Y, "Bubble DNA tweezer: a triple-conformation sensor responsive to concentration-ratios", iScience, 27, pp.109074~ (2024)