The Relationship between Transcranial Doppler Ultrasonography and Visual Field Test Results in Glaucoma and Glaucoma Suspect Patients
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: To evaluate the relationships between parameters of transcranial ultrasonography and results of visual field tests in patients with open angle glaucoma or suspected of having glaucoma. Methods: This retrospective study was based on data from medical records of patients who visited the Department of Ophthalmology in Kangbuk Samsung Hospital from January 1, 2016, to October 17, 2019, and underwent transcranial Doppler ultrasonography as part of a routine health examination. Ophthalmic data were visual acuity, intraocular pressure, optical coherence tomography, and Humphrey visual field test results. Retinal nerve fiber layer defect was confirmed by a glaucoma specialist. Patients’ ophthalmic data, such as average ganglion cell layer thickness, visual field index, pattern standard deviation, and mean deviation, were divided into quartiles. Each ophthalmic artery parameter from transcranial Doppler ultrasonography was compared between quartiles. Results: A total of 162 patients were reviewed. There was no difference in Doppler ophthalmic artery (OA) parameters between patients with or without retinal nerve fiber layer defect. None of the quartile groups of average ganglion cell layer thickness showed significant difference in any OA parameters. Patients in the low–visual field index quartile showed significant low peak systolic velocities of OAs when adjusted for age, sex, and presence of diabetes mellitus or hypertension (p = 0.016). A higher pattern standard deviation showed lower peak systolic velocity (p = 0.046). There was no significant tendency between any other OA parameter and mean deviation value. Conclusions: Our study suggests that hemodynamic parameters of ophthalmic arteries might be associated with visual field status of patients. Further large-population studies are needed in order to better understand the relationship between visual function and ocular blood flow.
Abstract
Purpose: To evaluate the relationships between parameters of transcranial ultrasonography and results of visual field tests in patients with open angle glaucoma or suspected of having glaucoma. Methods: This retrospective study was based on data from medical records of patients who visited the Department of Ophthalmology in Kangbuk Samsung Hospital from January 1, 2016, to October 17, 2019, and underwent transcranial Doppler ultrasonography as part of a routine health examination. Ophthalmic data were visual acuity, intraocular pressure, optical coherence tomography, and Humphrey visual field test results. Retinal nerve fiber layer defect was confirmed by a glaucoma specialist. Patients’ ophthalmic data, such as average ganglion cell layer thickness, visual field index, pattern standard deviation, and mean deviation, were divided into quartiles. Each ophthalmic artery parameter from transcranial Doppler ultrasonography was compared between quartiles. Results: A total of 162 patients were reviewed. There was no difference in Doppler ophthalmic artery (OA) parameters between patients with or without retinal nerve fiber layer defect. None of the quartile groups of average ganglion cell layer thickness showed significant difference in any OA parameters. Patients in the low–visual field index quartile showed significant low peak systolic velocities of OAs when adjusted for age, sex, and presence of diabetes mellitus or hypertension (p = 0.016). A higher pattern standard deviation showed lower peak systolic velocity (p = 0.046). There was no significant tendency between any other OA parameter and mean deviation value. Conclusions: Our study suggests that hemodynamic parameters of ophthalmic arteries might be associated with visual field status of patients. Further large-population studies are needed in order to better understand the relationship between visual function and ocular blood flow.
참고문헌 (39)
- Boland MV, "Comparative effectiveness of treatments for open-angle glaucoma: a systematic review for the U.S. Preventive Services Task Force", Ann Intern Med, 158, pp.271~279 (2013)
- Weinreb RN, "The pathophysiology and treatment of glaucoma : a review", JAMA, 311, pp.1901~1911 (2014)
- Weinreb RN, "WGA consensus series 6 : ocular blood flow in glaucoma" (2009), Kugler Publications
- Lee JS, "Systemic arterial stiffness is associated with structural progression in early open-angle glaucoma", Invest Ophthalmol Vis Sci, 63, pp.28~ (2022)
- Bae HW, "Systemic hypertension as a risk factor for open-angle glaucoma : a meta-analysis of population-based studies", PLoS One, 9, pp.e108226~ (2014)
- Zhou M, "Diabetes mellitus as a risk factor for open-angle glaucoma : a systematic review and meta-analysis", PLoS One, 9, pp.e102972~ (2014)
- Findl O, "Assessment of optic disk blood flow in patients with open-angle glaucoma", Am J Ophthalmol, 130, pp.589~596 (2000)
- Al Zoubi H, "Optic disc blood perfusion and oxygenation in glaucoma", Graefes Arch Clin Exp Ophthalmol, 260, pp.3587~3595 (2022)
- Flammer J, "What is the present pathogenetic concept of glaucomatous optic neuropathy?", Surv Ophthalmol, 52(Suppl 2), pp.S162~S173 (2007)
- Stalmans I, "Use of colour Doppler imaging in ocular blood flow research", Acta Ophthalmol, 89, pp.e609~30 (2011)
- Januleviciene I, "Diagnostic compatibility of structural and haemodynamic parameters in open-angle glaucoma patients", Acta Ophthalmol, 86, pp.552~557 (2008)
- Tiwari US, "Comparison of flow velocity in ophthalmic artery between glaucomatous and normal subjects", Rom J Ophthalmol, 63, pp.346~353 (2019)
- Samsudin A, "Ocular perfusion pressure and ophthalmic artery flow in patients with normal tension glaucoma", BMC Ophthalmol, 16, pp.39~ (2016)
- Butt Z, "Color Doppler imaging in untreated high-and normal-pressure open-angle glaucoma", Invest Ophthalmol Vis Sci, 38, pp.690~696 (1997)
- Abegao Pinto L, "Ophthalmic artery Doppler waveform changes associated with increased damage in glaucoma patients", Invest Ophthalmol Vis Sci, 53, pp.2448~2453 (2012)
- Bathala L, "Transcranial doppler : technique and common findings(part 1)", Ann Indian Acad Neurol, 16, pp.174~179 (2013)
- Wang HB, "Peak systolic velocity measurements with transcranial doppler ultrasound is a predictor of incident stroke among the general population in China", PLoS One, 11, pp.e0160967~ (2016)
- Adams R, "The use of transcranial ultrasonography to predict stroke in sickle cell disease", N Engl J Med, 326, pp.605~610 (1992)
- Wechsler LR, "Transcranial Doppler in cerebrovascular disease", Stroke, 17, pp.905~912 (1986)
- Costa VP, "Ocular perfusion pressure in glaucoma", Acta Ophthalmol, 92, pp.e252~66 (2014)
- Claassen JA, "Regulation of cerebral blood flow in humans : physiology and clinical implications of autoregulation", Physiol Rev, 101, pp.1487~1559 (2021)
- Flammer J, "The primary vascular dysregulation syndrome : implications for eye diseases", EPMA J, 4, pp.14~ (2013)
- Gherghel D, "Relationship between ocular perfusion pressure and retrobulbar blood flow in patients with glaucoma with progressive damage", Am J Ophthalmol, 130, pp.597~605 (2000)
- Flammer J, "Autoregulation, a balancing act between supply and demand", Can J Ophthalmol, 43, pp.317~321 (2008)
- Ahmad SS, "Controversies in the vascular theory of glaucomatous optic nerve degeneration", Taiwan J Ophthalmol, 6, pp.182~186 (2016)
- Wirostko BM, "The vascular theory in glaucoma", Glaucoma Today, pp.25~27 (2009)
- Williamson TH, "Ocular blood flow measurement", Br J Ophthalmol, 78, pp.939~945 (1994)
- Garzozi HJ, "Ocular blood flow measurements and their importance in glaucoma and age-related macular degeneration", Isr Med Assoc J, 3, pp.443~448 (2001)
- Rao HL, "Optical coherence tomography angiography in glaucoma", J Glaucoma, 29, pp.312~321 (2020)
- Chung JK, "Glaucoma diagnostic ability of the optical coherence tomography angiography vessel density parameters", Curr Eye Res, 42, pp.1458~1467 (2017)
- Kamalipour A, "OCT angiography artifacts in glaucoma", Ophthalmology, 128, pp.1426~1437 (2021)
- Moghimi S, "Optical coherence tomography angiography and glaucoma: a brief review", Asia Pac J Ophthalmol(Phila), 8, pp.115~125 (2019)
- Markus HS, "Transcranial Doppler ultrasound", J Neurol Neurosurg Psychiatry, 67, pp.135~137 (1999)
- Rojanapongpun P, "Ophthalmic artery flow velocity in glaucomatous and normal subjects", Br J Ophthalmol, 77, pp.25~29 (1993)
- Rojanapongpun P, "Reproducibility of transcranial Doppler ultrasound examinations of the ophthalmic artery flow velocity", Br J Ophthalmol, 77, pp.22~24 (1993)
- Doozandeh A, "Comparison of matrix frequency-doubling technology(FDT)perimetry with the SWEDISH interactive thresholding algorithm(SITA)standard automated perimetry(SAP)in mild glaucoma", Med Hypothesis Discov Innov Ophthalmol, 6, pp.98~104 (2017)
- Bozkurt B, "Relationship between Humphrey 30-2 SITA Standard Test, Matrix 30-2 threshold test, and Heidelberg retina tomograph in ocular hypertensive and glaucoma patients", J Glaucoma, 17, pp.203~210 (2008)
- Leske MC, "Risk factors for incident open-angle glaucoma : the Barbados Eye Studies", Ophthalmology, 115, pp.85~93 (2008)
- Sugiyama T, "Comparative study of cerebral blood flow in patients with normal-tension glaucoma and control subjects", Am J Ophthalmol, 141, pp.394~396 (2006)
