본문 바로가기
KERD
논문KCI 등재

Investigation of Gamma Radiation Shielding Properties of Polyethylene Glycol in the Energy Range from 8.67 to 23.19 keV

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

The mass attenuation coefficients (mm) of polyethylene glycol (PEG) of different molecular weights (1000e200,000) were measured using single-beam photon transmission. The X-ray fluorescent (XRF) photonsfrom Zinc (Zn), Zirconium (Zr), Molybdenum (Mo), Silver (Ag) and Cadmium (Cd) targets were used todetermine the attenuation of gamma radiation of energy range between 8.67 and 23.19 keV in PEGsamples. The results were compared to theoretical values using XCOM and Monte Carlo simulation usingGeant4 toolkit which was developed to validate the experiment at those certain energies. The massattenuation coefficients were then used to compute the effective atomic numbers, electron density andhalf value layers for the studied samples. The outcomes showed good agreement between experimentaland simulated results with those calculated theoretically by XCOM within 5% deviation. The PEG 1000sample showed slightly higher mm value compared with the other samples. The dependence of thephoton energy and PEG composition on the values of mm and HVL were investigated and discussed. Inaddition, the values of Zeff and Neff for all PEG samples behaved similarly in the given photon energyrange, and they decreased as the photon energy increased.

Abstract

The mass attenuation coefficients (mm) of polyethylene glycol (PEG) of different molecular weights (1000e200,000) were measured using single-beam photon transmission. The X-ray fluorescent (XRF) photonsfrom Zinc (Zn), Zirconium (Zr), Molybdenum (Mo), Silver (Ag) and Cadmium (Cd) targets were used todetermine the attenuation of gamma radiation of energy range between 8.67 and 23.19 keV in PEGsamples. The results were compared to theoretical values using XCOM and Monte Carlo simulation usingGeant4 toolkit which was developed to validate the experiment at those certain energies. The massattenuation coefficients were then used to compute the effective atomic numbers, electron density andhalf value layers for the studied samples. The outcomes showed good agreement between experimentaland simulated results with those calculated theoretically by XCOM within 5% deviation. The PEG 1000sample showed slightly higher mm value compared with the other samples. The dependence of thephoton energy and PEG composition on the values of mm and HVL were investigated and discussed. Inaddition, the values of Zeff and Neff for all PEG samples behaved similarly in the given photon energyrange, and they decreased as the photon energy increased.

참고문헌 (19)

  1. T. Singh, "Photon energy absorption parameters for some polymers", Ann. Nucl. Energy, 37, pp.422~427 (2010)[DOI]
  2. K. S. Mann, "Shielding behaviors of some polymer and plastic materials for gamma-rays", Radiat. Phys. Chem, 106, pp.247~254 (2015)[DOI]
  3. M. S. Al-Buriahi, "Radiation attenuation properties of some commercial polymers for advanced shielding applications at low energies", Polym. Adv. Technol, 32, pp.2386~2396 (2021)[DOI]
  4. M. I. Sayyed, "Investigation of shielding parameters for smart polymers", Chin. J. Phys, 54, pp.408~415 (2016)[DOI]
  5. Murat Kurudirek, "Effective atomic number, energy loss and radiation damage studies in some materials commonly used in nuclear applications for heavy charged particles such as H, C, Mg, Fe, Te, Pb and U", Radiation Physics and Chemistry, 122, pp.15~23 (2016), Elsevier BV[DOI]
  6. S. Haoue, "A new green catalyst for synthesis of bis-macromonomers of polyethylene glycol(PEG)", ChChT, 14, pp.468~473 (2020)[DOI]
  7. Ibrahim F. Al-Hamarneh, "Determination of gamma-ray parameters for polyethylene glycol of different molecular weights", Nuclear Science and Techniques, 28(11) (2017), Springer Science and Business Media LLC[DOI]
  8. "Bioconjugate Techniques" (2008), Elsevier
  9. W. Mccarthy, "Polymeric drug delivery techniques", Aldrich Mater. Sci, pp.3~12 (2016)
  10. J. Manson, "Polyethylene glycol functionalized gold nanoparticles : the influence of capping density on stability in various media", Gold Bull, 44, pp.99~105 (2011)[DOI]
  11. Benjamin D. Fairbanks, "Photoinitiated polymerization of PEG-diacrylate with lithium phenyl-2,4,6-trimethylbenzoylphosphinate: polymerization rate and cytocompatibility", Biomaterials, 30(35), pp.6702~6707 (2009), Elsevier BV[DOI]
  12. A. Larsson, "Photografted poly(ethylene glycol)matrix for affinity interaction studies", Biomacromolecules, 8, pp.287~295 (2007)[DOI]
  13. F. Bretagnol, "The effect of sterilization processes on the bioadhesive properties and surface chemistry of a plasma-polymerized polyethylene glycol film : XPS characterization and L929 cell proliferation tests", Acta Biomater, 4, pp.1745~1751 (2008)[DOI]
  14. J. H. Hubbell, "Photon mass attenuation and energy-absorption coefficients", Int. J. Appl. Radiat. Isot, 33, pp.1269~1290 (1982)[DOI]
  15. L. Gerward, "WinXComda program for calculating X-ray attenuation coefficients", Radiat. Phys. Chem, 71, pp.653~654 (2004)[DOI]
  16. K. Singh, "Gamma-ray attenuation coefficients in bismuth borate glasses", Nucl. Instrum. Methods Phys. Res. Sect. B Beam Interact. Mater. Atoms, 194, pp.1~6 (2002)[DOI]
  17. J. Kaewkhao, "Determination of effective atomic numbers and effective electron densities for Cu", Zn alloy, 2008, pp.109, 1260~1265
  18. A. Madhusudhan Rao, "Mass attenuation coefficients, effective atomic and electron numbers of alkali halides for multi-energetic photons", Res. J. Phys. Sci. Res. J. Phys. Sci, 1 (2013)
  19. S. Agostinelli, "Geant4da simulation toolkit", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 506, pp.250~303 (2003)[DOI]

관련 논문AI추천

Investigation of radiological properties and water equivalence of polymer gel dosimeters in the energy range 0.1–10 keVBüyükyıldız Mehmet, Kaur Parminder, Levet Aytaç, Parsaei Sara, Rafiei Mustafa Mohammad, Thakur Sonika한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제6호New polyester composites synthesized with additions of different sized ZnO to study their shielding efficiencyAlmuqrin Aljawhara H., Elsafi M., Sayyed M.I.한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제7호Gamma radiation shielding and interaction properties of MoO3-Doped cadmium zinc lithium-borate glassesAl-Buriahi M.S., Alomayrah Norah, Alzahrani Jamila S., Echeweozo E.O., Sriwunkum Chahkrit한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제4호Determination of X-ray and gamma-ray shielding capabilities of recycled glass derived from deteriorated silica gelAkharawutchayanon T., Issarapanacheewin S., Jaiboon O., Laopaiboon R., Sopapan P., Sriwunkum C., Yenchai C., Yubonmhat K.한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제9호Modeling the mass attenuation coefficient for Lead-Titanium-Zinc borate glasses using a piecewise power law modelAbughazaleh Baha’, Awwad Raed R. Abu, Sayyed M.I.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제12호Study the impact of MgO, Al2O3, MoO3, BaO, ZnO and PbO on the radiation shielding performance of borate glassesElsafi M., Hedaya A.M., Sayyed M.I.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제7호

이 간행물의 다른 논문 (21건)