솔레노이드 온도제어밸브 적용을 통한 온수기의 성능 개선 및 에너지절감
Energy Saving and Improvement of Performance of Calorifier by Applying Solenoid Temperature Control Valve
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
The Calorifier is a device that supplies hot water to the crew for showering and cooking. In particular, problems such as hot water not coming out when a trainee and a crew member take a shower at the same time may occur due to a malfunction of the temperature control valve that controls the temperature. In particular, when the hot water usage time is almost constant, such as a training ship, a high calorific value is required. When there is no dissatisfaction with the use of hot water, satisfaction with the educational environment is improved. Therefore, in this study, a solenoid temperature control valve is applied to increase satisfaction with hot water use, and a mechanical time switch is applied to the hot water circulating water pump to save energy.
Abstract
The Calorifier is a device that supplies hot water to the crew for showering and cooking. In particular, problems such as hot water not coming out when a trainee and a crew member take a shower at the same time may occur due to a malfunction of the temperature control valve that controls the temperature. In particular, when the hot water usage time is almost constant, such as a training ship, a high calorific value is required. When there is no dissatisfaction with the use of hot water, satisfaction with the educational environment is improved. Therefore, in this study, a solenoid temperature control valve is applied to increase satisfaction with hot water use, and a mechanical time switch is applied to the hot water circulating water pump to save energy.
참고문헌 (11)
- D. B. Lee, "Accelerated Life Test on Failer Mode of Calorifier for Vessel", Korean Society for power system Engineering, Fall Conference, pp.175~180 (2005)
- 이동원, "자연형 및 설비형 태양열 온수기의집열특성에 대한 실험적 연구", 한국태양에너지학회 논문집, 33(6), pp.12~18 (2013), 한국태양에너지학회
- 김득봉, "상선 위탁실습생의 업무실태 및 실습만족도에 관한 연구", 해양환경안전학회지, 24(6), pp.709~716 (2018), 해양환경안전학회[DOI]
- 신호식, "위탁선사 실습생의 승선실습 만족도에 관한 기초 연구", 수산해양교육연구, 27(2), pp.441~451 (2015), 한국수산해양교육학회
- Electric Instantaneous Water Heater, "H. G. Lee", Korean Consumer Agency, 622~639 (2000)
- D. B. Lee, "Root Cause Analysis on Failure Mode of Calorifier for Vessel", Jou. of the applied reliability, 6(1), pp.93~103 (2006)
- S. A. Yun, "A Study on Characteristic Improvement of On-OffSolenoid for Pneumatic", The Korean Society of Automative Engineers, Fall Conference, pp.1152~1157 (2003)
- K. H. Maeng, "An Alysis of Co2 Emission Using Power Consumption of Automotive lamps", The Korean Society of Automotive Engineers, Fall Conference, pp.800~800 (2013)
- 김홍렬, "LED 램프를 적용한 선실의 조도 및 소비전력 분석", 한국기계기술학회지, 15(4), pp.557~562 (2013), 한국기계기술학회[DOI]