Performance of Microflex LT Biotyper and VITEK MS for Routine Identification of Yeasts
2
조회
0
다운로드
0
인용
0
참고문헌
초록
Dear Editor, The epidemiology of yeast infections is rapidly evolving, leading to the emergence of uncommon yeasts [1]. Rapid identification, followed by appropriate antimicrobial therapy, is associated with lower mortality [2]. Conventional phenotypic methods cannot differentiate certain yeast species accurately [3]. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been introduced in clinical microbiology to facilitate rapid yeast identification [3]. MALDI-TOF MS for yeast identification requires special preparation, similar to that for Mycobacterium species and gram-positive bacteria [4]. We compared the yeast identification capabilities of two MALDI-TOF systems—the Microflex LT Biotyper (Bruker Daltonics, Leipzig, Germany) and the VITEK MS (bioMerieux, Marcy-l’Étoile, France)—with respect to different sample preparation methods.
Abstract
Dear Editor, The epidemiology of yeast infections is rapidly evolving, leading to the emergence of uncommon yeasts [1]. Rapid identification, followed by appropriate antimicrobial therapy, is associated with lower mortality [2]. Conventional phenotypic methods cannot differentiate certain yeast species accurately [3]. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been introduced in clinical microbiology to facilitate rapid yeast identification [3]. MALDI-TOF MS for yeast identification requires special preparation, similar to that for Mycobacterium species and gram-positive bacteria [4]. We compared the yeast identification capabilities of two MALDI-TOF systems—the Microflex LT Biotyper (Bruker Daltonics, Leipzig, Germany) and the VITEK MS (bioMerieux, Marcy-l’Étoile, France)—with respect to different sample preparation methods.
참고문헌 (10)
- Miceli MH, "Emerging opportunistic yeast infections", Lancet Infect Dis, 11, pp.142~151 (2011)[DOI]
- Morrell M, "Delaying the empiric treatment of Candida bloodstream infection until positive blood culture results are obtained: a potential risk factor for hospital mortality", Antimicrob Agents Chemother, 49, pp.3640~3645 (2005)[DOI]
- Dhiman N, "Performance and cost analysis of matrix-assisted laser desorption ionization-time of flight mass spectrometry for routine identification of yeast", J Clin Microbiol, 49, pp.1614~1616 (2011)[DOI]
- Theel ES, "Formic acid-based direct, on-plate testing of yeast and Corynebacterium species by Bruker Biotyper matrix-assisted laser desorption ionization-time of flight mass spectrometry", J Clin Microbiol, 50, pp.3093~3095 (2012)[DOI]
- 이현승, "Comparison of the Bruker Biotyper and VITEK MS Matrix- Assisted Laser Desorption", Ionization Time-of-Flight Mass Spectrometry Systems Using a Formic Acid Extraction Method to Identify Common and Uncommon Yeast Isolates, 2017, pp.37(3), 223~230[DOI]
- Chao QT, "Comparison of the accuracy of two conventional phenotypic methods and two MALDI-TOF MS systems with that of DNA sequencing analysis for correctly identifying clinically encountered yeasts", PLoS One, 9, pp.e109376~ (2014)[DOI]
- McTaggart LR, "Rapid identification of Cryptococcus neoformans and Cryptococcus gattii by matrix-assisted laser desorption ionization-time-of-flight mass spectrometry", J Clin Microbiol, 49, pp.3050~3053 (2011)[DOI]
- Pence MA, "Comparison and optimization of two MALDI-TOF MS platforms for the identification of medically relevant yeast species", Eur J Clin Microbiol Infect Dis, 33, pp.1703~1712 (2014)[DOI]
- Cassagne C, "Evaluation of four pretreatment procedures for MALDI-TOF MS yeast identification in the routine clinical laboratory", Med Mycol, 51, pp.371~377 (2013)[DOI]
- Vlek A, "Interlaboratory comparison of sample preparation methods, database expansions, and cutoff values for identification of yeasts by matrix-assisted laser desorption ionization-time of flight mass spectrometry using a yeast test panel", J Clin Microbiol, 52, pp.3023~3029 (2014)[DOI]
