On-line SPE-LC-Orbitrap 질량분석기를 활용한 잔류농약다성분 신속동시 분석방법연구
Simultaneous and Rapid Analysis of Multi-pesticide Residues usingOn-line SPE-LC-Orbitrap Mass Spectrometry
3
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In this study, we developed a rapid and simple analytical method for the simultaneous determination of pesticide residue in environmental water using an LC-Orbitrap (Q-Exactive Plus) with electrospray ionization mode. The detection process was performed in Full scan/ddMS2 mode. Sample preparation was performed using online SPE. Only 1 mL of each water sample was injected during the on-line SPE and the samples were ᅠ concentrated in a Hypersil GOLD aQ trapping column. We compared seven gradient programs and three analytical columns to analyze the 360 pesticides. Most compounds were detected using the CORTECS C18 column with the 7th gradient program method. The established method was validated by linearities, accuracy, precisions, and limits of quantification (LOQ) of the 340 pesticides. The calibration linearities were over 0.994 and LOQ were 5.2-283.3 ng/L. Accuracy and precision values were achieved in the ranges of 91-120% and ᅠ 0.63-8.21%, respectively. This method can be applied to effectively monitor the health of aquatic environments and can be potentially applicable in a variety of fields in the future.
Abstract
In this study, we developed a rapid and simple analytical method for the simultaneous determination of pesticide residue in environmental water using an LC-Orbitrap (Q-Exactive Plus) with electrospray ionization mode. The detection process was performed in Full scan/ddMS2 mode. Sample preparation was performed using online SPE. Only 1 mL of each water sample was injected during the on-line SPE and the samples were ᅠ concentrated in a Hypersil GOLD aQ trapping column. We compared seven gradient programs and three analytical columns to analyze the 360 pesticides. Most compounds were detected using the CORTECS C18 column with the 7th gradient program method. The established method was validated by linearities, accuracy, precisions, and limits of quantification (LOQ) of the 340 pesticides. The calibration linearities were over 0.994 and LOQ were 5.2-283.3 ng/L. Accuracy and precision values were achieved in the ranges of 91-120% and ᅠ 0.63-8.21%, respectively. This method can be applied to effectively monitor the health of aquatic environments and can be potentially applicable in a variety of fields in the future.
참고문헌 (19)
- J. Fenik, "Properties and determination of pesticides in fruits and vegetables", Trace Trends analytical Chemistry, 30, pp.814~826 (2011)
- B. Bordas, "Theoretical molecular descriptors relevant to the uptake of persistent organic pollutants from soil by zucchini. A QSAR study", Journal Agric Food Chemistry, 59, pp.2863~2869 (2011)
- 도정아, "국내 유통 농산물 중 잔류농약 모니터링", 한국식품영양과학회지, 39(6), pp.902~908 (2010), 한국식품영양과학회
- Ministry of Food and Drug Safety, "Handbook for the pesticide residue analytical methods of Food Code Index", pp.10~1278 (2017)
- 이동열, "매실 중 살균제 azoxystrobin과 difenoconazole의 생산단계 잔류허용기준 설정", 농약과학회지, 17(4), pp.307~313 (2013), 한국농약과학회
- N. Chamkasem, "“Analysis of 136 pesticides in avocado using a modified QuEChERS method with LC-MS", MS and GCMS, Journal of agricultural and food chemistry, pp.2013, 61[DOI]
- 옥환석, "잔류농약 분석방법의 개발 동향", 농약과학회지, 13(4), pp.336~348 (2009), 한국농약과학회
- 남선화, "비규제 농약 관리를 위한 한국, 유럽, 미국의 농약관리체계 비교분석", Journal of Applied Biological Chemistry, 61(2), pp.195~204 (2018), 한국응용생명화학회
- J. Cotton, "Development and calidation of a multiresidue method for the analysis of more than 500 pesticides and drugs in water based on on-line and liquid chromatography coupled to high resolution mass spectrometry", Water Research, 104, pp.20~27 (2016)
- Q. Hu, "The Orbitrap: a new mass spectrometer", Journal of Mass spectrometry, 40, pp.430~443 (2005)
- O. Lange, "Enhanced Fourier transform for Orbitrap mass spectrometry", International Journal of Mass Spectrometry, 369, pp.16~22 (2014)
- J. R. Molina, "Multi-residue method for the determination of over 400 priority and emerging pollutants in water and wastewater by solid-phase extraction and liquid chromatography-time-of-flight mass spectrometry", Journal of Chromatography A, 1350, pp.30~43 (2014)
- N. I. Rousis, "Monitoring a large number of pesticides and transformation procucts in water samples from Spain and Italy", Environmental Research, 156, pp.31~38 (2017)
- A. Alves, "Case Study on Screening Emerging Pollutants in Urine and Nails", Environmental Science and Technoloty, 51, pp.4046~4053 (2017)
- European Committee for Standardization, "High-Resolution Accuracy Mass (HRAMS) methods for the screening of pesticides not approved under Reg. (EC) Nº 1107", 2009 using exact mass libraries and databases, 2019, pp.3~9
- 박근영, "LC", MS, 분석과학, pp.2018, 31(1)[DOI]
- A. Meierjohann, "“An on-line SPE LC-MS", MS method for the analysis of antibiotics in environmental water, 2017, pp.24, 8692~8699
- M. L. Gómez-Pérez, "Analysis of veterinary drug and pesticide residues in animal feed by high-resolution mass spectrometry: comparison between time-of-flight and Orbitrap", Food Additives and Contaminants, 32, pp.1637~1646 (2015)
- K. C. Sik, "Determination of 18 veterinary antibiotics in environmental water using high-performance liquid chromatography-q-orbitrap combined with on-line solid-phase extraction", Journal of Chromatography B, 1084, pp.158~165 (2018)