본문 바로가기
KERD
논문KCI 등재

Pre-transfusion Testing Using Crossmatching Agglutination Reaction Grades Combined With Rh Subgroup Phenotyping in Patients With Autoantibodies: A Three-year Experience at a Tertiary Hospital

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류병리학

초록

Background: The currently recommended pre-transfusion testing techniques for patients with autoantibodies are complex, time-consuming, and labor-intensive. Therefore, although the red blood cell (RBC) selection method using crossmatched RBC agglutination reaction grades (i.e., the “least incompatible” transfusion) is discouraged, many institutions still use it. We aimed to evaluate the effectiveness of this method combined with Rh subgroup phenotyping. Methods: We retrospectively investigated RBC transfusions from January 2019 to December 2021 in patients presenting as auto-control-positive via antibody identification (auto-control (+) group), where Rh subgroup phenotype-matched RBCs were selected based on the agglutination reaction grades of crossmatched units. For each study patient, an auto-control-negative patient was matched based on age, sex, department, and pre-transfusion Hb levels (auto-control (−) group). The mean Hb change per unit, transfusion-associated symptom/sign reports, and agglutination reaction grades upon crossmatching were analyzed. Results: In the auto-control (+) group, the Hb change per unit among different agglutination reaction grades of transfused RBCs and among different relative grades of transfused RBCs and crossmatching auto-controls was not significantly different (P=0.392 and P= 0.132, respectively). No significant difference was observed in Hb changes and transfusion-associated symptom/sign occurrence between the auto-control (+) and auto-control (−) groups (P=0.121 and P=0.822, respectively). In addition, no definite evidence of hemolysis in the auto-control (+) group was observed in the medical record review. Conclusions: Together with Rh subgroup phenotyping, selecting the RBC unit with the lowest agglutination reaction grade upon crossmatching does not adversely affect transfusion efficiency.

Abstract

Background: The currently recommended pre-transfusion testing techniques for patients with autoantibodies are complex, time-consuming, and labor-intensive. Therefore, although the red blood cell (RBC) selection method using crossmatched RBC agglutination reaction grades (i.e., the “least incompatible” transfusion) is discouraged, many institutions still use it. We aimed to evaluate the effectiveness of this method combined with Rh subgroup phenotyping. Methods: We retrospectively investigated RBC transfusions from January 2019 to December 2021 in patients presenting as auto-control-positive via antibody identification (auto-control (+) group), where Rh subgroup phenotype-matched RBCs were selected based on the agglutination reaction grades of crossmatched units. For each study patient, an auto-control-negative patient was matched based on age, sex, department, and pre-transfusion Hb levels (auto-control (−) group). The mean Hb change per unit, transfusion-associated symptom/sign reports, and agglutination reaction grades upon crossmatching were analyzed. Results: In the auto-control (+) group, the Hb change per unit among different agglutination reaction grades of transfused RBCs and among different relative grades of transfused RBCs and crossmatching auto-controls was not significantly different (P=0.392 and P= 0.132, respectively). No significant difference was observed in Hb changes and transfusion-associated symptom/sign occurrence between the auto-control (+) and auto-control (−) groups (P=0.121 and P=0.822, respectively). In addition, no definite evidence of hemolysis in the auto-control (+) group was observed in the medical record review. Conclusions: Together with Rh subgroup phenotyping, selecting the RBC unit with the lowest agglutination reaction grade upon crossmatching does not adversely affect transfusion efficiency.

참고문헌 (13)

  1. Garratty G, "Approaches to selecting blood for transfusion to patients with autoimmune hemolytic anemia", Transfusion, 42, pp.1390~1392 (2002)
  2. Salama A, "Red blood cell transfusion in warm-type autoimmune haemolytic anaemia", Lancet, 340, pp.1515~1517 (1992)
  3. Petz LD, "A physician’s guide to transfusion in autoimmune haemolytic anaemia", Br J Haematol, 124, pp.712~716 (2004)
  4. Ziman A, "Warm-reactive(immunoglobulin G)autoantibodies and laboratory testing best practices : review of the literature and survey of current practice", Transfusion, 57, pp.463~477 (2017)
  5. Reardon JE, "Laboratory evaluation and transfusion support of patients with autoimmune hemolytic anemia", Am J Clin Pathol, 125, pp.S71~7 (2006)
  6. Leger RM, "Evaluation of methods for detecting alloantibodies underlying warm autoantibodies", Transfusion, 39, pp.11~16 (1999)
  7. Petz LD, "“Least incompatible” units for transfusion in autoimmune hemolytic anemia: should we eliminate this meaningless term? A commentary for clinicians and transfusion medicine professionals", Transfusion, 43, pp.1503~1507 (2003)
  8. 박상혁, "Red Blood Cell Transfusion in Patients With Autoantibodies: Is It Effective and Safe Without Increasing Hemolysis Risk?", Annals of Laboratory Medicine, 35(4), pp.436~444 (2015), 대한진단검사의학회
  9. Chen C, "Autoimmune hemolytic anemia in hospitalized patients : 450 patients and their red blood cell transfusions", Medicine, 99, pp.e18739~ (2020)
  10. Dwyre DM, "A red blood cell autoantibody with mimicking anti-E specificity", Transfusion, 44, pp.1287~1292 (2004)
  11. Issitt PD, "Studies of antibodies in the sera of patients who have made red cell autoantibodies", Transfusion, 36, pp.481~486 (1996)
  12. 장민중, "Autoantibodies with Mimicking Specificity Detected by the Dilution Technique in Patients with Warm Autoantibodies", Annals of Laboratory Medicine, 33(5), pp.343~348 (2013), 대한진단검사의학회
  13. Wheeler CA, "Warm reactive autoantibodies : clinical and serologic correlations", Am J Clin Pathol, 122, pp.680~685 (2004)

관련 논문AI추천

Autoantibodies with Mimicking Specificity Detected by the Dilution Technique in Patients with Warm Autoantibodies조덕, 박경운, 서순팔, 신명근, 신종희, 양동욱, 장민중, Mark Harris Yazer대한진단검사의학회 · Annals of Laboratory Medicine2013 · 제33권 제5호Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies김형회, 김혜림, 신경화, 이주미, 이현지, 장철훈, 조수연대한진단검사의학회 · Annals of Laboratory Medicine2017 · 제37권 제2호Comparison of ABO Antibody Titers on the Basis of the Antibody Detection Method Used강선주, 백새윤, 임영애대한진단검사의학회 · Annals of Laboratory Medicine2014 · 제34권 제4호Acute Hemolysis Due to Rh Antibodies Against C and e Antigens after Rh-incompatible Transfusion in a Patient, Not Detected During Pre-transfusion Testing김근주, 김인숙, 오승환, 이현지대한진단검사의학회 · Laboratory Medicine Online2021 · 제11권 제2호Red Blood Cell Transfusion in Patients With Autoantibodies: Is It Effective and Safe Without Increasing Hemolysis Risk?권석운, 박상혁, 최원호대한진단검사의학회 · Annals of Laboratory Medicine2015 · 제35권 제4호ABO Antibody Titer Testing Harmonization in Korea: A 5-Year Analysis of External Quality Control DataChung Yousun, Hwang Sang-Hyun, Kim Han Joo, Kim Hyungsuk, Ko Dae-Hyun, Oh Heung-Bum대한진단검사의학회 · Annals of Laboratory Medicine2025 · 제45권 제3호

이 간행물의 다른 논문 (18건)