200kW 탑형 태양열발전시스템에서 사용되는 Heliostat의 집열특성 분석
Analysis of Energy Concentration Characteristics of Heliostat used in 200kW Tower Type Solar Thermal Power Plant
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Heliostatinthetowertypesolarthermalpowerplantisasuntrackingmirrorsystem toreflectthesolarenergy tothereceiverandtheopticalperformanceofitaffectstotheefficiencyofwholepowerplantmostsignificantly.Thus asolidunderstandingofheliostat'senergyconcentrationcharacteristicsisthemostimportantstepindesigningofthe heliostatfieldandthewholepowerplant. Theworkpresentedhereistheanalysisofenergyconcentrationcharacteristicsofheliostatusedin200kW solar thermalpowerplant,wherethereceiverlocatedat43m highintowerhas2x2m rectangularshape.Theheliostat reflectivesurfaceisformedby4of1x1m flatplatemirrorfacetandthemirrorfacetismountedonthesphericalframe. Thedirectnormalincidentradiation modelsin vernalequinox,summersolstice,autumnalequinox andwinter solsticearefirstderivedfrom theactuallymeasureddata.Thentheinterceptratio,heatfluxdistributionandtotal energycollectedatthereceiverfortheheliostatslocatedinthevariousplacesoftheheliostatfieldareinvestigated. Finallytheeffectofmirrorfacetinstallationerrorontheopticalperformanceoftheheliostatisanalyzed.
Abstract
Heliostatinthetowertypesolarthermalpowerplantisasuntrackingmirrorsystem toreflectthesolarenergy tothereceiverandtheopticalperformanceofitaffectstotheefficiencyofwholepowerplantmostsignificantly.Thus asolidunderstandingofheliostat'senergyconcentrationcharacteristicsisthemostimportantstepindesigningofthe heliostatfieldandthewholepowerplant. Theworkpresentedhereistheanalysisofenergyconcentrationcharacteristicsofheliostatusedin200kW solar thermalpowerplant,wherethereceiverlocatedat43m highintowerhas2x2m rectangularshape.Theheliostat reflectivesurfaceisformedby4of1x1m flatplatemirrorfacetandthemirrorfacetismountedonthesphericalframe. Thedirectnormalincidentradiation modelsin vernalequinox,summersolstice,autumnalequinox andwinter solsticearefirstderivedfrom theactuallymeasureddata.Thentheinterceptratio,heatfluxdistributionandtotal energycollectedatthereceiverfortheheliostatslocatedinthevariousplacesoftheheliostatfieldareinvestigated. Finallytheeffectofmirrorfacetinstallationerrorontheopticalperformanceoftheheliostatisanalyzed.
참고문헌 (14)
- 박문희, "대구도시가스 파워타워 프로젝트현황 소개", 한국태양에너지학회지, 9(2), pp.14~18 (2010)
- 박영칠, "200kW 탑형 태양열발전시스템을 위한 Heliostat 반사면 구조 설계", 한국태양에너지학회 논문집, 31(2), pp.53~62 (2011), 한국태양에너지학회
- Y.T.Chen, "Off-axis aberrationcorrectionsurfaceinsolarenergy application", SolarEnergy, 80, pp.268~271 (2006)
- R.Zaibel, "An astigmaticcorrected targetaligned heliostatforhigh concentration", Solar Energy Materials and SolarCells, 37, pp.191~202 (1995)
- E.A.Igel, "Opticalanalysis ofsolarfacilityheliostats", SolarEnergy, 22, pp.283~295 (1979)
- F.J.Collard, "Ananalyticfunctionforthefluxdensity duetosunlightreflectedfrom aheliostat", SolarEnergy, 37, pp.215~234 (1986)
- F.W.Lippsa, "Ananalytic evaluation ofthe flux density due to sunlightreflectedfrom aflatmirrorhaving apolygonalboundary", SolarEnergy, 21, pp.113~121 (1978)
- R.B.Pettit, "Simplified calculational procedure for determining the amountofintercepted sunlightinanimagingsolarconcentrator", JournalofSolarEnergyEngineering, 105, pp.101~107 (1983)
- M.D.Walzel, "A solarflux density calculation fora solar tower concentrator using a two dimensionalHermitefunctionexpansion", SolarEnergy, 19, pp.239~253 (1977)
- J.C.Henne, "Ananalytical methodforreflectedfluxdensitycalculations", SolarEnergy, 32, pp.357~363 (1984)
- F.W.Lipps, "Fourdifferentviewsofthe heliostat flux density integral", Solar Energy, 18, pp.555~560 (1976)
- F.W.Lipps, "A numericalapproachto the flux density integralforreflected sunlight", SolarEnergy, 24, pp.461~469 (1980)
- 조덕기, "국내 태양열발전단지 건설을 위한 법선면 직달일사량 자원조사", 한국태양에너지학회 논문집, 25(1), pp.11~18 (2005), 한국태양에너지학회
- 유호천, "대한민국 표준기상데이터의 변화추이와 건물부하량에 관한 기초연구", 한국태양에너지학회 논문집, 29(3), pp.66~72 (2009), 한국태양에너지학회
