본문 바로가기
KERD
논문KCI 등재

Uncertainty assessment for a towed underwater stereo PIV system by uniform flow measurement

1

조회

0

다운로드

5

인용

0

참고문헌

키워드

주제분류조선공학

초록

The present study aims to assess test uncertainty assessment method of nominal wake field measurement by a Stereoscopic Particle Image Velocimetry (SPIV) system in a towing tank. The systematic uncertainty of the SPIV system was estimated from repeated uniform flow measurements. In the uniform flow measurement case, time interval between image frames and uniform flow speed were varied to examine the effects of particle displacement and flow around the SPIV system on the systematic standard uncertainty. The random standard uncertainty was assessed by repeating nominal wake field measurements and the estimated random standard uncertainty was compared with that of laser Doppler velocimetry. The test uncertainty assessment method was applied to nominal wake measurement tests of a very large crude oil carrier model ship. The nominal wake measurement results were compared with existing experimental database by other measurement methods, with its assessed uncertainty.

Abstract

The present study aims to assess test uncertainty assessment method of nominal wake field measurement by a Stereoscopic Particle Image Velocimetry (SPIV) system in a towing tank. The systematic uncertainty of the SPIV system was estimated from repeated uniform flow measurements. In the uniform flow measurement case, time interval between image frames and uniform flow speed were varied to examine the effects of particle displacement and flow around the SPIV system on the systematic standard uncertainty. The random standard uncertainty was assessed by repeating nominal wake field measurements and the estimated random standard uncertainty was compared with that of laser Doppler velocimetry. The test uncertainty assessment method was applied to nominal wake measurement tests of a very large crude oil carrier model ship. The nominal wake measurement results were compared with existing experimental database by other measurement methods, with its assessed uncertainty.

참고문헌 (24)

  1. Adrian, R.J., "Particle Image Velocimetry" (2011), Cambridge University Press
  2. Anschau, P., "Application of a stereo PIV system for investigations of flow fields in towing tank and cavitation tunnel", Arch. Civ. Mech. Eng., 7(3), pp.5~17 (2007)
  3. American Society of Mechanical Engineers, "Test Uncertainty. The American Society of Mechanical Engineers Performance Test Code, 19.1", ~ (2005)
  4. Calluaud, D., "Stereoscopic particle image velocimetry measurements of the flow around a surface-mounted block", Exp. Fluids, 36(1), pp.53~61 (2004)[DOI]
  5. Grizzi, S., "A simplified, flow-based calibration method for stereoscopic PIV", Exp. Fluids, 48(3), pp.473~486 (2010)[DOI]
  6. Gui, L., "Biases of PIV measurement of turbulent flow and the masked correlation-based interrogation algorithm", Exp. Fluids, 30(1), pp.27~35 (2001)[DOI]
  7. Gui, L., "Towing tank PIV measurement system, data, and uncertainty assessment for DTMB model 5512", Exp. Fluids, 31(3), pp.336~346 (2001)[DOI]
  8. International Towing Tank Conference, "Guide to the expression of uncertainty in experimental hydrodynamics", International Towing Tank Conference Recommended Procedures and Guidelines (2008)
  9. International Towing Tank Conference, "Uncertainty analysis: particle image velocimetry", International Towing Tank Conference Recommended Procedures and Guidelines (2008)
  10. International Towing Tank Conference, "Recommended procedures and guidelines: ship models", International Towing Tank Conference Recommended Procedures and Guidelines (2011)
  11. Kim, W.J., "Measurement of flows around modern commercial ship models", Exp. Fluids, 31(5), pp.567~578 (2001)[DOI]
  12. Kume, K., "Measurements of hydrodynamic forces, surface pressure, and wake for obliquely towed tanker model and uncertainty analysis for CFD validation", J. Mar. Sci. Technol., 11(2), pp.65~75 (2006)[DOI]
  13. Lee, S.J., "Wind tunnel tests on flow characteristics of the KRISO 3,600 TEU Containership and 300K VLCC double-deck ship models", J. Ship Res., 47(1), pp.24~38 (2003)
  14. Longo, J., "Uncertainty assessment for towing tank tests with example for surface combatant DTMB model 5415", J. Ship Res., 49(1), pp.55~68 (2005)
  15. Nobach, H., "Limitations of accuracy in PIV due to individual variations of particle image intensities", Exp. Fluids, 47(1), pp.27~38 (2009)[DOI]
  16. Raffel, M., "Particle Image Velocimetry: a Practical Guide" (1998), Springer
  17. Sciacchitano, A., "PIV uncertainty quantification by image matching", Meas. Sci. Technol., 24(4), pp.045302~ (2013)[DOI]
  18. Seo, J., "Turbulent wake field reconstruction of VLCC models using two-dimensional towed underwater PIV measurements", Ocean. Eng., 118, pp.28~40 (2016)[DOI]
  19. Seo, J., "Influence of design parameter variations for propeller-boss-cap-fins on hub vortex reduction", J. Ship Res., 60(4), pp.1~16 (2016)[DOI]
  20. Seo, J., "Experimental study on kinetic energy conversion of horizontal axis tidal stream turbine", Renew. Energy, 97, pp.784~797 (2016)[DOI]
  21. 설동명, "Towed underwater PIV measurement for free-surface effects on turbulent wake of a surface-piercing body", International Journal of Naval Architecture and Ocean Engineering, 5(3), pp.404~413 (2013), 대한조선학회
  22. Timmins, B.H., "A method for automatic estimation of instantaneous local uncertainty in particle image velocimetry measurements", Exp. Fluids, 53(4), pp.1133~1147 (2012)[DOI]
  23. Wilson, B.M., "Uncertainty on PIV mean and fluctuating velocity due to bias and random errors", Meas. Sci. Technol., 24(3), pp.035302~ (2013)[DOI]
  24. Yoon, H., "Benchmark CFD validation data for surface combatant 5415 in PMM maneuvers - Part II: phase-averaged stereoscopic PIV flow field measurements", Ocean. Eng., 109, pp.735~750 (2015)[DOI]