C-arm fluoroscopy is useful equipment in interventional pain management because it helps to guide correct needle targeting for the accurate injection and drug delivery. However, due to increased use of C-arm fluoroscopy in various pain procedures, the risk of radiation exposure is a significant concern for pain physicians. The harmful biological effects of ionizing radiation on the human body are well known. It is therefore necessary to strive to reduce radiation exposure. Lead aprons with thyroid shields are the most fundamental radiation protective devices for interventional procedures, and are very effective. However, the operator’s radiation safety cannot be guaranteed because pain physicians seem to lack sufficient interest, knowledge, and awareness about radiation safety. Also, inappropriate care and use of radiation protective devices may result in a higher risk of radiation exposure. The purpose of this article was to review the literature on radiation safety with a focus on lead aprons and thyroid shields and present recommendations related to those devices during C-arm fluoroscopic-guided interventions by pain physicians. (Korean J Pain 2018; 31: 244-52)

Abstract

C-arm fluoroscopy is useful equipment in interventional pain management because it helps to guide correct needle targeting for the accurate injection and drug delivery. However, due to increased use of C-arm fluoroscopy in various pain procedures, the risk of radiation exposure is a significant concern for pain physicians. The harmful biological effects of ionizing radiation on the human body are well known. It is therefore necessary to strive to reduce radiation exposure. Lead aprons with thyroid shields are the most fundamental radiation protective devices for interventional procedures, and are very effective. However, the operator’s radiation safety cannot be guaranteed because pain physicians seem to lack sufficient interest, knowledge, and awareness about radiation safety. Also, inappropriate care and use of radiation protective devices may result in a higher risk of radiation exposure. The purpose of this article was to review the literature on radiation safety with a focus on lead aprons and thyroid shields and present recommendations related to those devices during C-arm fluoroscopic-guided interventions by pain physicians. (Korean J Pain 2018; 31: 244-52)

참고문헌 (54)

  1. SuYoungKim, "Factors Affecting Radiation Exposure during Lumbar Epidural Steroid Injection: A Prospective Study in 759 Patients", Korean Journal of Radiology, 17(3), pp.405~412 (2016), 대한영상의학회[DOI]
  2. Linet MS, "Historical review of occupational exposures and cancer risks in medical radiation workers", Radiat Res, 174, pp.793~808 (2010)[DOI]
  3. Tae Wan Kim, "Radiation Exposure to Physicians During Interventional Pain Procedures", The Korean Journal of Pain, 23(1), pp.24~27 (2010), 대한통증학회
  4. Tsapaki V, "Correlation of patient and staff doses in interventional cardiology", Radiat Prot Dosimetry, 117, pp.26~29 (2005)[DOI]
  5. 김태희, "The radiation safety education and the pain physicians’efforts to reduce radiation exposure", The Korean Journal of Pain, 30(2), pp.104~115 (2017), 대한통증학회
  6. Pyong Eun Park, "Radiation Safety and Education in the Applicants of the Final Test for the Expert of Pain Medicine", The Korean Journal of Pain, 25(1), pp.16~21 (2012), 대한통증학회
  7. Fishman SM, "Radiation safety in pain medicine", Reg Anesth Pain Med, 27, pp.296~305 (2002)[DOI]
  8. Kim C, "Radiation safety among cardiology fellows", Am J Cardiol, 106, pp.125~128 (2010)[DOI]
  9. Dagal A, "Radiation safety for anesthesiologists", Curr Opin Anaesthesiol, 24, pp.445~450 (2011)[DOI]
  10. Manchikanti L, "Radiation exposure to the physician in interventional pain management", Pain Physician, 5, pp.385~393 (2002)
  11. Le Heron J, "Radiation protection of medical staff", Eur J Radiol, 76, pp.20~23 (2010)[DOI]
  12. Blakely EA, "Biological effects of cosmic radiation: deterministic and stochastic", Health Phys, 79, pp.495~506 (2000)[DOI]
  13. Shortt CP, "Thyroid dose during neurointerventional procedures: does lead shielding reduce the dose?", Cardiovasc Intervent Radiol, 30, pp.922~927 (2007)[DOI]
  14. Sont WN, "First analysis of cancer incidence and occupational radiation exposure based on the National Dose Registry of Canada", Am J Epidemiol, 153, pp.309~318 (2001)[DOI]
  15. Manchikanti L, "Effectiveness of protective measures in reducing risk of radiation exposure in interventional pain management: a prospective evaluation", Pain Physician, 6, pp.301~305 (2003)
  16. Broadman LM, "Radiation risk management during fluoroscopy for interventional pain medicine physicians", Curr Pain Headache Rep, 8, pp.49~55 (2004)[DOI]
  17. Zhou Y, "Fluoroscopy radiation safety for spine interventional pain procedures in university teaching hospitals", Pain Physician, 8, pp.49~53 (2005)
  18. Roguin A, "Brain and neck tumors among physicians performing interventional procedures", Am J Cardiol, 111, pp.1368~1372 (2013)[DOI]
  19. Leuraud K, "Ionising radiation and risk of death from leukaemia and lymphoma in radiation-monitored workers (INWORKS): an international cohort study", Lancet Haematol, 2, pp.e276~e281 (2015)[DOI]
  20. Andreassi MG, "Subclinical carotid atherosclerosis and early vascular aging from long-term low-dose ionizing radiation exposure: a genetic, telomere, and vascular ultrasound study in cardiac catheterization laboratory staff", JACC Cardiovasc Interv, 8, pp.616~627 (2015)
  21. Biswas D, "Radiation exposure from musculoskeletal computerized tomographic scans", J Bone Joint Surg Am, 91, pp.1882~1889 (2009)[DOI]
  22. Stewart FA, "ICRP publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs--threshold doses for tissue reactions in a radiation protection context", Ann ICRP, 41, pp.1~322 (2012)
  23. International Commission on Radiological Protection (ICRP), "Statement on tissue reactions. Approved by the commission on April 21, 2011. ICRP ref 4825-3093-1464", International Commission on Radiological Protection, ~ (2011)
  24. Mahesh M, "Fluoroscopy: patient radiation exposure issues", Radiographics, 21, pp.1033~1045 (2001)[DOI]
  25. Manchikanti L, "Risk of whole body radiation exposure and protective measures in fluoroscopically guided interventional techniques: a prospective evaluation", BMC Anesthesiol, 3, pp.2~ (2003)[DOI]
  26. Botwin KP, "Radiation exposure to the physician performing fluoroscopically guided caudal epidural steroid injections", Pain Physician, 4, pp.343~348 (2001)
  27. Botwin KP, "Radiation exposure of the spinal interventionalist performing fluoroscopically guided lumbar transforaminal epidural steroid injections", Arch Phys Med Rehabil, 83, pp.697~701 (2002)[DOI]
  28. Botwin KP, "Radiation exposure to the spinal interventionalist performing lumbar discography", Pain Physician, 6, pp.295~300 (2003)
  29. Wang RR, "Occupational radiation exposure of anesthesia providers: a summary of key learning points and resident-led radiation safety projects", Semin Cardiothorac Vasc Anesth, 21, pp.165~171 (2017)[DOI]
  30. Statkiewicz-Sherer MA, "Radiation protection in medical radiography" (1998), Mosby
  31. Hanu-Cernat DE, "Type of interventional pain procedure, body weight, and presence of spinal pathology are determinants of the level of radiation exposure for fluoroscopically guided pain procedures", Pain Pract, 12, pp.434~439 (2012)[DOI]
  32. Schueler BA, "Operator shielding: how and why", Tech Vasc Interv Radiol, 13, pp.167~171 (2010)[DOI]
  33. 백승우, "A Randomized Controlled Trial about the Levels of Radiation Exposure Depends on the Use of Collimation C-arm Fluoroscopic-guided Medial Branch Block", The Korean Journal of Pain, 26(2), pp.148~153 (2013), 대한통증학회
  34. Srinivasan D, "Radiation safety and spine surgery: systematic review of exposure limits and methods to minimize radiation exposure", World Neurosurg, 82, pp.1337~1343 (2014)[DOI]
  35. Radiation dose management for fluoroscopically-guided interventional medical procedures. NCRP report 168, "National Council on Radiation Protection", National Council on Radiation Protection and Measurements, ~ (2012)
  36. Chou LB, "Prevalence of cancer in female orthopaedic surgeons in the United States", J Bone Joint Surg Am, 92, pp.240~244 (2010)
  37. Klein LW, "Occupational health hazards in the interventional laboratory time for a safer environment: time for a safer environment", J Vasc Interv Radiol, 20, pp.147~152 (2009)[DOI]
  38. Alexandre D, "Wearing lead aprons in surgical operating rooms: ergonomic injuries evidenced by infrared thermography", J Surg Res, 209, pp.227~233 (2017)[DOI]
  39. Klein LW, "Occupational health hazards of interventional cardiologists in the current decade: results of the 2014 SCAI membership survey", Catheter Cardiovasc Interv, 86, pp.913~924 (2015)[DOI]
  40. Dixon RG, "Society of Interventional Radiology: Occupational Back and Neck Pain and the Interventional Radiologist", J Vasc Interv Radiol, 28, pp.195~199 (2017)[DOI]
  41. Papadopoulos N, "Comparison of lead-free and conventional X-ray aprons for diagnostic radiology", World congress on medical physics and biomedical engineering, pp.544~546 (2009)
  42. Sawdy JM, "Radiation protection during hybrid procedures: innovation creates new challenges", J Invasive Cardiol, 21, pp.437~440 (2009)
  43. Badawy MK, "A review of radiation protection solutions for the staff in the cardiac catheterisation laboratory", Heart Lung Circ, 25, pp.961~967 (2016)[DOI]
  44. 류재성, "The Survey about the Degree of Damage of Radiation-Protective Shields in Operation Room", The Korean Journal of Pain, 26(2), pp.142~147 (2013), 대한통증학회
  45. Devalia KL, "Exposure of the thyroid to radiation during routine orthopaedic procedures", Acta Orthop Belg, 72, pp.615~620 (2006)
  46. Muller LP, "Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing", Injury, 29, pp.461~468 (1998)[DOI]
  47. Health risks from exposure to low levels of Ionizing radiation: BEIR VII, phase I, letter report, , ~ (1998)
  48. Lee SY, "Types and arrangement of thyroid shields to reduce exposure of surgeons to ionizing radiation during intraoperative use of C-arm fluoroscopy", Spine, 38, pp.2108~2112 (2013)[DOI]
  49. Iglesias ML, "Radiation exposure and thyroid cancer: a review", Arch Endocrinol Metab, 61, pp.180~187 (2017)[DOI]
  50. Gendelberg D, "A radiation safety training program results in reduced radiation exposure for orthopaedic residents using the mini C-arm", Clin Orthop Relat Res, 474, pp.580~584 (2016)[DOI]
  51. Frederick-Dyer KC, "Online training on the safe use of fluoroscopy can result in a significant decrease in patient dose", Acad Radiol, 20, pp.1272~1277 (2013)[DOI]
  52. Tuncer N, "Orthopedic surgeons' knowledge regarding risk of radiation exposition: a survey analysis", SICOT J, 3, pp.29~ (2017)[DOI]
  53. Lynskey GE 3rd, "Radiation protection in interventional radiology: survey results of attitudes and use", J Vasc Interv Radiol, 24, pp.1547~1551 (2013)[DOI]
  54. Slegers AS, "Coaching reduced the radiation dose of pain physicians by half during interventional procedures", Pain Pract, 15, pp.400~406 (2015)[DOI]