초록

Purpose: This study aimed to examine the inter-method reliability and volumetric differences between NeuroQuant (NQ) and Freesurfer (FS) using T1 volume imaging sequence with different slice thicknesses in patients with mild cognitive impairment (MCI). Materials and Methods: This retrospective study enrolled 80 patients diagnosed with MCI at our memory clinic. NQ and FS were used for volumetric analysis of three-dimensional T1-weighted images with slice thickness of 1 and 1.2 mm. Inter-method reliability was measured with Pearson correlation coefficient (r), intraclass correlation coefficient (ICC), and effect size (ES). Results: Overall, NQ volumes were larger than FS volumes in several locations: whole brain (0.78%), cortical gray matter (5.34%), and white matter (2.68%). Volume measures by NQ and FS showed good-to-excellent ICCs with both 1 and 1.2 mm slice thickness (ICC=0.75–0.97, ES=-1.0–0.73 vs. ICC=0.78–0.96, ES=-0.9–0.77, respectively), except for putamen, pallidum, thalamus, and total intracranial volumes. The ICCs in all locations, except the putamen and cerebellum, were slightly higher with a slice thickness of 1 mm compared to those of 1.2 mm. Conclusion: Inter-method reliability between NQ and FS was good-to-excellent in most regions with improvement with a 1-mm slice thickness. This finding indicates that the potential effects of slice thickness should be considered when performing volumetric measurements for cognitive impairment.

Abstract

Purpose: This study aimed to examine the inter-method reliability and volumetric differences between NeuroQuant (NQ) and Freesurfer (FS) using T1 volume imaging sequence with different slice thicknesses in patients with mild cognitive impairment (MCI). Materials and Methods: This retrospective study enrolled 80 patients diagnosed with MCI at our memory clinic. NQ and FS were used for volumetric analysis of three-dimensional T1-weighted images with slice thickness of 1 and 1.2 mm. Inter-method reliability was measured with Pearson correlation coefficient (r), intraclass correlation coefficient (ICC), and effect size (ES). Results: Overall, NQ volumes were larger than FS volumes in several locations: whole brain (0.78%), cortical gray matter (5.34%), and white matter (2.68%). Volume measures by NQ and FS showed good-to-excellent ICCs with both 1 and 1.2 mm slice thickness (ICC=0.75–0.97, ES=-1.0–0.73 vs. ICC=0.78–0.96, ES=-0.9–0.77, respectively), except for putamen, pallidum, thalamus, and total intracranial volumes. The ICCs in all locations, except the putamen and cerebellum, were slightly higher with a slice thickness of 1 mm compared to those of 1.2 mm. Conclusion: Inter-method reliability between NQ and FS was good-to-excellent in most regions with improvement with a 1-mm slice thickness. This finding indicates that the potential effects of slice thickness should be considered when performing volumetric measurements for cognitive impairment.

참고문헌 (27)

  1. Brewer JB, "Fully-automated quantification of regional brain volumes for improved detection of focal atrophy in Alzheimer disease", AJNR Am J Neuroradiol, 30, pp.578~580 (2009)
  2. Braak H, "Neuropathological stageing of Alzheimer-related changes", Acta Neuropathol, 82, pp.239~259 (1991)
  3. Jack CR Jr, "Medial temporal atrophy on MRI in normal aging and very mild Alzheimer’s disease", Neurology, 49, pp.786~794 (1997)
  4. 박미나, "Structural MR Imaging in the Diagnosis of Alzheimer’s Disease and Other Neurodegenerative Dementia: Current Imaging Approach and Future Perspectives", Korean Journal of Radiology, 17(6), pp.827~845 (2016), 대한영상의학회[DOI]
  5. Min J, "Diagnostic efficacy of structural MRI in patients with mild-to-moderate Alzheimer disease : automated volumetric assessment versus visual assessment", AJR Am J Roentgenol, 208, pp.617~623 (2017)
  6. Jenkinson M, "FSL", Neuroimage, 62, pp.782~790 (2012)
  7. Smith SM, "Advances in functional and structural MR image analysis and implementation as FSL", Neuroimage, 23(Suppl 1), pp.S208~S219 (2004)
  8. Ashburner J, "Voxel-based morphometry--the methods", Neuroimage, 11(6 Pt 1), pp.805~821 (2000)
  9. Fischl B, "FreeSurfer", Neuroimage, 62, pp.774~781 (2012)
  10. Brewer JB, "Fully-automated volumetric MRI with normative ranges : translation to clinical practice", Behav Neurol, 21, pp.21~28 (2009)
  11. Birk S, "Hippocampal atrophy : biomarker for early AD? Hippocampal volume in patients with AD is typically two standard deviations below normal", Internal Medicine News, 42, pp.12~ (2009)
  12. Kovacevic S, "High-throughput, fully automated volumetry for prediction of MMSE and CDR decline in mild cognitive impairment", Alzheimer Dis Assoc Disord, 23, pp.139~145 (2009)
  13. Ochs AL, "Comparison of automated brain volume measures obtained with NeuroQuant® and FreeSurfer", J Neuroimaging, 25, pp.721~727 (2015)
  14. Baker M, "Is there a reproducibility crisis? A Nature survey lifts the lid on how researchers view the’crisis rocking science and what they think will help", Nature, 533, pp.452~455 (2016)
  15. Ross DE, "High correlations between MRI brain volume measurements based on NeuroQuant® and FreeSurfer", Psychiatry Res Neuroimaging, 278, pp.69~76 (2018)
  16. Storelli L, "Measurement of whole-brain and gray matter atrophy in multiple sclerosis : assessment with MR imaging", Radiology, 288, pp.554~564 (2018)
  17. Fischl B, "Whole brain segmentation : automated labeling of neuroanatomical structures in the human brain", Neuron, 33, pp.341~355 (2002)
  18. Bigler ED, "Diffuse damage in pediatric traumatic brain injury : a comparison of automated versus operator-controlled quantification methods", Neuroimage, 50, pp.1017~1026 (2010)
  19. Petersen RC, "Mild cognitive impairment : clinical characterization and outcome", Arch Neurol, 56, pp.303~308 (1999)
  20. Ferreira D, "Multiple sclerosis patients lacking oligoclonal bands in the cerebrospinal fluid have less global and regional brain atrophy", J Neuroimmunol, 274, pp.149~154 (2014)
  21. Guo C, "Repeatability and reproducibility of FreeSurfer, FSL-SIENAX and SPM brain volumetric measurements and the effect of lesion filling in multiple sclerosis", Eur Radiol, 29, pp.1355~1364 (2019)
  22. Koo TK, "A guideline of selecting and reporting intraclass correlation coefficients for reliability research", J Chiropr Med, 15, pp.155~163 (2016)
  23. Cohen J, "Statistical power analysis for the behavioral sciences" (1988), Lawrence Erlbaum Associates
  24. Stein JL, "Identification of common variants associated with human hippocampal and intracranial volumes", Nat Genet, 44, pp.552~561 (2012)
  25. "NeuroQuant 3.0: scanner parameters"[URL]
  26. Olejnik S, "Measures of effect size for comparative studies : applications, interpretations, and limitations", Contemp Educ Psychol, 25, pp.241~286 (2000)
  27. Gronenschild EH, "The effects of FreeSurfer version, workstation type, and Macintosh operating system version on anatomical volume and cortical thickness measurements", PLoS One, 7, pp.e38234~ (2012)

관련 논문AI추천

Comparison of Vendor-Provided Volumetry Software and NeuroQuant Using 3D T1-Weighted Images in Subjects with Cognitive Impairment: How Large is the Inter-Method Discrepancy?김하영, 문연실, 문원진, Jieun Chung대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2020 · 제24권 제2호Evaluation of Reproducibility of Brain Volumetry between Commercial Software, Inbrain and Established Research Purpose Method, FreeSurfer문연실, 문원진, 박지은, 오세원, 이정빈, 이지영, 전홍준, 정미선대한신경과학회 · Journal of Clinical Neurology2021 · 제17권 제2호Assessment of Mild Cognitive Impairment in Elderly Subjects Using a Fully Automated Brain Segmentation Software강경미, Chiheon Kwon, Chul-Ho Sohn, Dahyun Yi, Dong Young Lee, Huijin Song, Inpyeong Hwang, Ji-hoon Kim, Ji Ye Lee, Min Soo Byun, Roh-Eul Yoo, Seung Hong Choi, Tae Jin Yun, the KBASE Research Group대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2021 · 제25권 제3호Exploratory Non-Inferiority Validation of an East Asian-Based MRI Brain Volumetric Software김동현, 김은영, 김지민, 민은정, 오세원, 이승수, 이하영, Hye Weon Kim, ZunHyan Rieu대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2025 · 제29권 제3호Intra-Rater and Inter-Rater Reliability of Brain Surface Intensity Model (BSIM)-Based Cortical Thickness Analysis Using T MRI문연실, 문원진, 전지영, 한설희대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2015 · 제19권 제3호Assessing the Impact of Defacing Algorithms on Brain Volumetry Accuracy in MRI AnalysesChungHwee Lee, Dong Won Yang, Dong-Woo Ryu, Hyuk-je Lee, Jong-Min Lee, Jung Hee Cho, Seonggyu Kim, Yong S Shim, Yun Jeong Hong대한치매학회 · Dementia and Neurocognitive Disorders(대한치매학회지)2024 · 제23권 제3호

이 간행물의 다른 논문 (8건)