본문 바로가기
KERD
논문KCI 등재

일측성 난청 환자에서 골전도 보청기의 효능

Efficacy of Implantable Bone Conduction Hearing Aids in Single-Sided Deafness

1

조회

0

다운로드

1

인용

0

참고문헌

주제분류이비인후과학

초록

As the technology advances and bone conduction implant (BCI) use increases, implantablebone conduction hearing aids are regarded as a treatment method for single-sided deafness(SSD) and their efficacy on SSD must be discussed. Therefore, we organized the problems ofSSD and types of implantable bone conduction hearing aids and explained their effectivenessin the treatment of SSD in terms of changes in 1) speech recognition in a noisy environment,2) sound localization, 3) subjective satisfaction as assessed by questionnaire, and 4) tinnitus. Although bone conduction hearing aids do not significantly improve localization ability inSSD, they increase the ability to listen under noise, increasing subjective satisfaction. Tinnitusimprovement was also reported. The active forms of BCI like MED-EL BONEBRIDGE®2and Cochlear Osia®2 have been developed well. Based on these technological developmentsand effects, bone conduction hearing aids would be a good option for treatment option of SSD.

Abstract

As the technology advances and bone conduction implant (BCI) use increases, implantablebone conduction hearing aids are regarded as a treatment method for single-sided deafness(SSD) and their efficacy on SSD must be discussed. Therefore, we organized the problems ofSSD and types of implantable bone conduction hearing aids and explained their effectivenessin the treatment of SSD in terms of changes in 1) speech recognition in a noisy environment,2) sound localization, 3) subjective satisfaction as assessed by questionnaire, and 4) tinnitus. Although bone conduction hearing aids do not significantly improve localization ability inSSD, they increase the ability to listen under noise, increasing subjective satisfaction. Tinnitusimprovement was also reported. The active forms of BCI like MED-EL BONEBRIDGE®2and Cochlear Osia®2 have been developed well. Based on these technological developmentsand effects, bone conduction hearing aids would be a good option for treatment option of SSD.

참고문헌 (36)

  1. Stenfelt S, "Bone-conducted sound: Physiological and clinical aspects", Otol Neurotol, 26(6), pp.1245~1261 (2005)
  2. Stenfelt S, "Acoustic and physiologic aspects of bone conduction hearing", Adv Otorhinolaryngol, 71, pp.10~21 (2011)
  3. Sohmer H, "Bone conduction experiments in humans - a fluid pathway from bone to ear", Hear Res, 146(1-2), pp.81~88 (2000)
  4. Ito T, "Bone conduction thresholds and skull vibration measured on the teeth during stimulation at different sites on the human head", Audiol Neurootol, 16(1), pp.12~22 (2011)
  5. Brantberg K, "Enhanced auditory sensitivity to body vibrations in superior canal dehiscence syndrome", Audiol Neurootol, 21(6), pp.365~371 (2016)
  6. Chiossoine-Kerdel JA, "An investigation of the audiologic handicap associated with unilateral sudden sensorineural hearing loss", Am J Otol, 21(5), pp.645~651 (2000)
  7. Welsh LW, "Functional impairments due to unilateral deafness", Ann Otol Rhinol Laryngol, 113(12), pp.987~993 (2004)
  8. Kim G, "Efficacy of bone-anchored hearing aids in single-sided deafness: A systematic review", Otol Neurotol, 38(4), pp.473~483 (2017)
  9. Niparko JK, "Comparison of the bone anchored hearing aid implantable hearing device with contralateral routing of offside signal amplification in the rehabilitation of unilateral deafness", Otol Neurotol, 24(1), pp.73~78 (2003)
  10. Snik AF, "Consensus statements on the BAHA system: Where do we stand at present?", Ann Otol Rhinol Laryngol Suppl, 195, pp.2~12 (2005)
  11. Giolas TG, "Communication problems associated with unilateral hearing loss", J Speech Hear Disord, 32(4), pp.336~343 (1967)
  12. Oberzut C, "Directionality and the head-shadow effect", Hear J, 56(4), pp.56~ (2003)
  13. Fourcin AJ, "Binaural pitch phenomena", J Acoust Soc Am, 34(12), pp.1995~ (1962)
  14. Colburn HS, "The perceptual consequences of binaural hearing", J Audiol., 45(Suppl 1), pp.S34~S44 (2006)
  15. Wazen JJ, "Transcranial contralateral cochlear stimulation in unilateral deafness", Otolaryngol Head Neck Surg, 129(3), pp.248~254 (2003)
  16. Agterberg MJH, "Sound-localization performance of patients with singlesided deafness is not improved when listening with a bone-conduction device", Hear Res, 372, pp.62~68 (2019)
  17. Baguley DM, "The evidence base for the application of contralateral bone anchored hearing aids in acquired unilateral sensorineural hearing loss in adults", Clin Otolaryngol, 31(1), pp.6~14 (2006)
  18. Bosman AJ, "On the evaluation of a superpower sound processor for bone-anchored hearing", Clin Otolaryngol, 43(2), pp.450~455 (2018)
  19. Zernotti ME, "Active bone conduction prosthesis : Bonebridge(TM)", Int Arch Otorhinolaryngol, 19(4), pp.343~348 (2015)
  20. Håkansson B, "The bone conduction implant-a review and 1-year follow-up", Int J Audiol, 58(12), pp.945~955 (2019)
  21. Persson AC, "Three-year follow-up with the bone conduction implant", Audiol Neurootol, pp.1~13 (2020)
  22. Nilsson M, "Development of the Hearing in Noise Test for the measurement of speech reception thresholds in quiet and in noise", J Acoust Soc Am, 95(2), pp.1085~1099 (1994)
  23. 임현우, "소아에서 한국어 Hearing in Noise Test의 유효성", 대한이비인후-두경부외과학회지, 54(7), pp.462~466 (2011), 대한이비인후과학회
  24. Andersen HT, "Unilateral deafness after acoustic neuroma surgery : Subjective hearing handicap and the effect of the bone-anchored hearing aid", Otol Neurotol, 27(6), pp.809~814 (2006)
  25. Snapp HA, "Speech perception outcomes in transcutaneous versus percutaneous bone conduction stimulation in individuals with single-sided deafness", Otol Neurotol, 40(8), pp.1068~1075 (2019)
  26. Kurz A, "Speech understanding with a new implant technology: A comparative study with a new nonskin penetrating Baha system", Biomed Res Int, 2014, pp.416205~ (2014)
  27. Newman CW, "Longitudinal benefit from and satisfaction with the Baha system for patients with acquired unilateral sensorineural hearing loss", Otol Neurotol, 29(8), pp.1123~1131 (2008)
  28. Galvin JJ 3rd, "Benefits of cochlear implantation for single-sided deafness:Data from the House Clinic-University of Southern California-University of California, Los Angeles clinical trial", Ear Hear, 40(4), pp.766~781 (2019)
  29. Keating P, "Sound localization in a changing world", Curr Opin Neurobiol, 35, pp.35~43 (2015)
  30. Hol MK, "Bone-anchored hearing aids in patients with acquired and congenital unilateral inner ear deafness (Baha CROS): Clinical evaluation of 56 cases", Ann Otol Rhinol Laryngol, 119(7), pp.447~454 (2010)
  31. Cox RM, "The abbreviated profile of hearing aid benefit", Ear Hear, 16(2), pp.176~186 (1995)
  32. 장동수, "Baha Attract Implantation Using a Small Incision: Initial Report of Surgical Technique and Surveillance", Clinical and Experimental Otorhinolaryngology, 13(1), pp.15~22 (2020), 대한이비인후과학회[DOI]
  33. Kong TH, "Evaluation of wireless bluetooth devices to improve recognition of speech and sentences when using a mobile phone in bone conduction device recipients", Eur Arch Otorhinolaryngol, 276(10), pp.2729~2737 (2019)
  34. Holder JT, "Cochlear implantation for single-sided deafness and tinnitus suppression", Am J Otolaryngol, 38(2), pp.226~229 (2017)
  35. Punte AK, "Cochlear implantation as a durable tinnitus treatment in single-sided deafness", Cochlear Implants Int, 12(Suppl 1), pp.S26~S29 (2011)
  36. Holgers KM, "Sound stimulation via bone conduction for tinnitus relief: A pilot study", Int J Audiol, 41(5), pp.293~300 (2002)

관련 논문AI추천

이식형 골도 보청기의 발전과 앞으로의 발전김세아, 한우재대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2018 · 제61권 제2호수술 후 발생한 일측성 난청에서 OsiaⓇ2 골전도 임플란트를 이용한 청각재활문서진, 문인석대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2023 · 제66권 제2호Effect of Bonebridge Implantation on Tinnitus in Patients With Asymmetric Hearing Loss or Single-Sided Deafness김연지, 박소영, 박시내, 서재현, 한재상, Celeste Ann Chua대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2022 · 제65권 제10호일측성 전농 환자에서의 청력 재활: 바하와 크로스 보청기의 이득과 선택 기준김성헌, 문인석, 박미나, 유신영, 전영명대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2013 · 제56권 제6호Hearing Rehabilitation Using Bone Conduction Implants in Patients With Single-Sided Deafness After Vestibular Schwannoma Removal문인석, 박주하, 이정금대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2023 · 제66권 제8호좌우 비대칭형 난청 환자에서 CROS 보청기와 이식형 골도보청기의 선택 과정과 착용 전후 청력역치의 비교구자윤, 김용한, 박홍주, 배미례, 신철호, 이호준대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2019 · 제62권 제3호

이 간행물의 다른 논문 (4건)