Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

2

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류내과학

초록

Background/Aims: Despite the clinical importance and widespread use of pulse wave velocity (PWV), there are no standards for pulse sensors or for system requirements to ensure accurate pulse wave measurement. We assessed the reproducibility of PWV values using a newly developed PWV measurement system. Methods: The system used in this study was the PP-1000, which simultaneously provides regional PWV values from arteries at four different sites (carotid, femoral, radial, and dorsalis pedis). Seventeen healthy male subjects without any cardiovascular disease participated in this study. Two observers performed two consecutive measurements in the same subject in random order. To evaluate the reproducibility of the system, two sets of analyses (within-observer and between-observer) were performed. Results: The means±SD of PWV for the aorta, arm, and leg were 7.0±1.48, 8.43±1.14, and 8.09±0.98 ㎧ as measured by observer A and 6.76±1.00, 7.97±0.80, and 7.97±0.72 ㎧ by observer B, respectively. Betweenobserver differences for the aorta, arm, and leg were 0.14±0.62, 0.18±0.84, and 0.07±0.86 ㎧, respectively, and the correlation coefficients were high, especially for aortic PWV (r=0.93). All the measurements showed significant correlation coefficients, ranging from 0.94 to 0.99. Conclusions: The PWV measurement system used in this study provides accurate analysis results with high reproducibility. It is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform.

Abstract

Background/Aims: Despite the clinical importance and widespread use of pulse wave velocity (PWV), there are no standards for pulse sensors or for system requirements to ensure accurate pulse wave measurement. We assessed the reproducibility of PWV values using a newly developed PWV measurement system. Methods: The system used in this study was the PP-1000, which simultaneously provides regional PWV values from arteries at four different sites (carotid, femoral, radial, and dorsalis pedis). Seventeen healthy male subjects without any cardiovascular disease participated in this study. Two observers performed two consecutive measurements in the same subject in random order. To evaluate the reproducibility of the system, two sets of analyses (within-observer and between-observer) were performed. Results: The means±SD of PWV for the aorta, arm, and leg were 7.0±1.48, 8.43±1.14, and 8.09±0.98 ㎧ as measured by observer A and 6.76±1.00, 7.97±0.80, and 7.97±0.72 ㎧ by observer B, respectively. Betweenobserver differences for the aorta, arm, and leg were 0.14±0.62, 0.18±0.84, and 0.07±0.86 ㎧, respectively, and the correlation coefficients were high, especially for aortic PWV (r=0.93). All the measurements showed significant correlation coefficients, ranging from 0.94 to 0.99. Conclusions: The PWV measurement system used in this study provides accurate analysis results with high reproducibility. It is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform.

참고문헌 (17)

  1. O’Rourke M, "principles in arterial disease", Hypertension, 26, pp.2~9 (1995)
  2. Arnold JM, "Large artery function in patients with chronic heart failure", Circulation, 84, pp.2418~2425 (1991)
  3. Hollock P, "Arterial elasticity in man in relation to age as evaluated by the pulse wave velocity method", Arch Intern Med, 54, pp.770~794 (1934)
  4. Safar ME, "The arterial system in hypertension: a prospective view", Hypertension, 26, pp.10~14 (1995)
  5. Lehmann ED, "Sonksen PH. Arterial wall compliance in diabetes", Diabet Med, 9, pp.114~119 (1992)
  6. Simonson E, "Effect of age on pulse wave velocity and aortic ejection time in healthy men and in men with coronary artery disease", Circulation, 22, pp.126~129 (1960)
  7. Bolster BD Jr, "Accuracy of arterial pulse wave velocity measurement using MR", Magn Reson Imaging, 8, pp.878~888 (1998)
  8. Lehmann ED, "Non-invasive Doppler ultrasound technique for the in vivo assessment of aortic compliance", J Biomed Eng, 14, pp.250~256 (1992)
  9. Baguet JP, "Analysis of the regional pulse wave velocity by Doppler: methodology and reproducibility", Hum Hypertens, 17, pp.407~412 (2003)
  10. Chiu YC, "Determination of pulse wave velocities with computerized algorithms", Am Heart J, 121, pp.1460~1470 (1991)
  11. McDonald DA, "Regional pulse wave velocity in the arterial tree", J Appl Physiol, 24, pp.73~78 (1968)
  12. O’Rourke MF, "Wave reflection in the systemic circulation and its implications in ventricular function", J Hypertens, 11, pp.327~337 (1993)
  13. Lantelme P, "Heart rate: an important confounder of pulse wave velocity assessment", Hypertension, 39, pp.1083~1087 (2002)
  14. Boland JM, "Statistical methods for assessing agreement between two methods of clinical measurement", Lancet, 1, pp.307~310 (1986)
  15. Asmar R, "Assessment of arterial distensibility by automatic pulse wave velocity measurement: validation and clinical application studies", Hypertension, 26, pp.485~490 (1995)
  16. Willkinson IB, "Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis", J Hypertens, 16, pp.2079~2084 (1998)
  17. Lehmann ED, "Gosling RG. Aortic compliance measurements using Doppler ultrasound: In vivo biochemical correlates", Ultrasound Med Biol, 19, pp.683~710 (1993)

관련 논문AI추천

이 간행물의 다른 논문 (10건)