본문 바로가기
KERD
논문KCI 등재

The Selection of the Appropriate Computer Interface Device for Patients With High Cervical Cord Injury

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류재활의학

초록

In order to determine the most suitable computer interfaces for patients with high cervical cord injury, we report three cases of applications of special input devices. The first was a 49-year-old patient with neurological level of injury (NLI) C4, American Spinal Injury Association Impairment Scale (ASIA)-A. He could move the cursor by using a webcam-based Camera Mouse. Moreover, clicking the mouse could only be performed by pronation of the forearm on the modified Micro Light Switch. The second case was a 41-year-old patient with NLI C3, ASIA-A. The SmartNav 4AT which responds according to head movements could provide stable performance in clicking and dragging. The third was a 13-year-old patient with NLI C1, ASIA-B. The IntegraMouse enabling clicking and dragging with fine movements of the lips. Selecting the appropriate interface device for patients with high cervical cord injury could be considered an important part of rehabilitation. We expect the standard proposed in this study will be helpful.

Abstract

In order to determine the most suitable computer interfaces for patients with high cervical cord injury, we report three cases of applications of special input devices. The first was a 49-year-old patient with neurological level of injury (NLI) C4, American Spinal Injury Association Impairment Scale (ASIA)-A. He could move the cursor by using a webcam-based Camera Mouse. Moreover, clicking the mouse could only be performed by pronation of the forearm on the modified Micro Light Switch. The second case was a 41-year-old patient with NLI C3, ASIA-A. The SmartNav 4AT which responds according to head movements could provide stable performance in clicking and dragging. The third was a 13-year-old patient with NLI C1, ASIA-B. The IntegraMouse enabling clicking and dragging with fine movements of the lips. Selecting the appropriate interface device for patients with high cervical cord injury could be considered an important part of rehabilitation. We expect the standard proposed in this study will be helpful.

참고문헌 (7)

  1. Chen YL., "A head movement image(HMI)-controlled computer mouse for people with disabilities", Disabil Rehabil, 25, pp.163~167 (2003)
  2. 엄광문, "경수 손상 환자에서 컴퓨터 마우스 인터페이스의 조작능력 및 만족도", Annals of Rehabilitation Medicine, 30(3), pp.230~235 (2006), 대한재활의학회
  3. 이범석, "지역사회에 거주하는 경수4번 척수장애인들의 삶", Annals of Rehabilitation Medicine, 31(2), pp.188~195 (2007), 대한재활의학회
  4. Betke M., "The Camera Mouse : visual tracking of body features to provide computer access for people with severe disabilities", IEEE Trans Neural Syst Rehabil Eng, 10, pp.1~10 (2002)
  5. Kim YW., "Development of headset-type computer mouse using gyro sensors for the handicapped", Electron Lett, 38, pp.1313~1314 (2002)
  6. Evans DG., "Controlling mouse pointer position using an infrared head-operated joystick", IEEE Trans Rehabil Eng, 8, pp.107~117 (2000)
  7. Barea R., "System for assisted mobility using eye movements based on electrooculography", IEEE Trans Neural Syst Rehabil Eng, 10, pp.209~218 (2002)

관련 논문AI추천

이 간행물의 다른 논문 (21건)