본문 바로가기
KERD
논문KCI 등재

Visual Evoked Potential Using Head-Mounted Display Versus Cathode Ray Tube: A Pilot Study

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류재활의학

초록

Objective To present a new stimulation method based on the use of a head-mounted display (HMD) during pattern reversal visual evoked potential (PR-VEP) testing and to compare variables of HMD to those of conventional cathode ray tube (CRT).Methods Twenty-three normal subjects without visual problems were recruited. PR-VEPs were generated using CRT or HMD stimuli. VEP outcome measures included latencies (N75, P100, and N145) and peak-to-peak amplitudes (N75–P100 and P100–N145). Subjective discomfort associated with HMD was determined using a self-administered questionnaire.Results PR-VEPs generated by HMD stimuli showed typical triphasic waveforms, the components of which were found to be correlated with those obtained using conventional CRT stimuli. Self-administered discomfort questionnaires revealed that HMD was more comfortable in some aspects. It allowed subjects to concentrate better than CRT.Conclusion The described HMD stimulation can be used as an alternative to the standard CRT stimulation for PR-VEPs. PR-VEP testing using HMD has potential applications in clinical practice and visual system research because HMD can be used on a wider range of subjects compared to CRT.

Abstract

Objective To present a new stimulation method based on the use of a head-mounted display (HMD) during pattern reversal visual evoked potential (PR-VEP) testing and to compare variables of HMD to those of conventional cathode ray tube (CRT).Methods Twenty-three normal subjects without visual problems were recruited. PR-VEPs were generated using CRT or HMD stimuli. VEP outcome measures included latencies (N75, P100, and N145) and peak-to-peak amplitudes (N75–P100 and P100–N145). Subjective discomfort associated with HMD was determined using a self-administered questionnaire.Results PR-VEPs generated by HMD stimuli showed typical triphasic waveforms, the components of which were found to be correlated with those obtained using conventional CRT stimuli. Self-administered discomfort questionnaires revealed that HMD was more comfortable in some aspects. It allowed subjects to concentrate better than CRT.Conclusion The described HMD stimulation can be used as an alternative to the standard CRT stimulation for PR-VEPs. PR-VEP testing using HMD has potential applications in clinical practice and visual system research because HMD can be used on a wider range of subjects compared to CRT.

참고문헌 (21)

  1. Cobb WA, "The latency and form in man of the occipital potentials evoked by bright flashes", J Physiol, 152, pp.108~121 (1960)
  2. Vaughan HG Jr, "Functional relation between stimulus intensity and photically evoked cerebral responses in man", Nature, 206, pp.720~722 (1965)
  3. Odom JV, "Visual evoked potentials standard (2004)", Doc Ophthalmol, 108, pp.115~123 (2004)
  4. Jeffrey LC, "Physical medicine and rehabilitation:principles and practice", pp.105~137 (2005), Lippincott Williams & Wilkins
  5. Velger M, "Helmet-mounted displays and sights", pp.10~15 (1998), Artech House
  6. Hanprasertpong C, "A head-mounted visual stimulator for neurotological examination", Auris Nasus Larynx, 31, pp.379~382 (2004)
  7. Melzer JE, "Head mounted displays: designing for the user", pp.1~16 (1997), McGraw-Hill
  8. International Organization for Standardization, "International standard-ergonomic requirements for office work with visual display terminals (VDTs). Part 3: visual display requirements", ISO 9241-3:1992, International Organization for Standardization, ~ (1992)
  9. Oosterhuis HJ, "The average visual response in patients with cerebrovascular disease", Electroencephalogr Clin Neurophysiol, 27, pp.23~34 (1969)
  10. Klassen AC, "Hypercapnic alteration of visual evoked responses in acute cerebral infarction", Arch Neurol, 36, pp.627~629 (1979)
  11. Misulis KE, "Spehlmann’s evoked potential primer", pp.137~155 (2001), Butterworth-Heinemann
  12. Bodis-Wollner I, "Evoked potentials", pp.15~27 (1986), Liss
  13. Celesia GG, "Anatomy and physiology of the visual system", J Clin Neurophysiol, 11, pp.482~492 (1994)
  14. Brigell M, "Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision. Calibration Standard Committee of the International Society for Clinical Electrophysiology of Vision (ISCEV)", Doc Ophthalmol, 95, pp.1~14 (1998)
  15. Celesia GG, "Evoked potential techniques in the evaluation of visual function", J Clin Neurophysiol, 1, pp.55~76 (1984)
  16. Tobimatsu S, "Effects of pupil diameter and luminance changes on pattern electroretinograms and visual evoked potentials", Clin Vision Sci, 2, pp.293~302 (1988)
  17. Tobimatsu S, "Age-related changes in pattern visual evoked potentials: differential effects of luminance, contrast and check size", Electroencephalogr Clin Neurophysiol, 88, pp.12~19 (1993)
  18. Kurita-Tashima S, "Effect of check size on the pattern reversal visual evoked potential", Electroencephalogr Clin Neurophysiol, 80, pp.161~166 (1991)
  19. Patterson R, "Perceptual issues in the use of head-mounted visual displays", Hum Factors, 48, pp.555~573 (2006)
  20. Mon-Williams M, "Binocular vision in a virtual world: visual deficits following the wearing of a head-mounted display", Ophthalmic Physiol Opt, 13, pp.387~391 (1993)
  21. Peli E, "The visual effects of head-mounted display (HMD) are not distinguishable from those of desk-top computer display", Vision Res, 38, pp.2053~2066 (1998)