The Availability of Radiological Measurement of Femoral Anteversion Angle: Three-Dimensional Computed Tomography Reconstruction
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Objective To assess the intra-rater and inter-rater reliability for measuring femoral anteversion angle (FAA) by a radiographic method using three-dimensional computed tomography reconstruction (3D-CT).Methods The study included 82 children who presented with intoeing gait. 3D-CT data taken between 2006 and 2014 were retrospectively reviewed. FAA was measured by 3D-CT. FAA is defined as the angle between the long axis of the femur neck and condylar axis of the distal femur. FAA measurement was performed twice at both lower extremities by each rater. The intra-rater and inter-rater reliability were calculated by intraclass correlation coefficient (ICC). Results One hundred and sixty-four lower limbs of 82 children (31 boys and 51 girls, 6.3±3.2 years old) were included. The ICCs of intra-rater measurement for the angle of femoral neck axis (NA) were 0.89 for rater A and 0.96 for rater B, and those of condylar axis (CA) were 0.99 for rater A and 0.99 for rater B, respectively. The ICC of inter-rater measurement for the angle of NA was 0.89 and that of CA was 0.92. By each rater, the ICCs of the intra-rater measurement for FAA were 0.97 for rater A and 0.95 for rater B, respectively and the ICC of the inter-rater measurement for FAA was 0.89. Conclusion The 3D-CT measures for FAA are reliable within individual raters and between different raters. The 3D-CT measures of FAA can be a useful method for accurate diagnosis and follow-up of femoral anteversion.
Abstract
Objective To assess the intra-rater and inter-rater reliability for measuring femoral anteversion angle (FAA) by a radiographic method using three-dimensional computed tomography reconstruction (3D-CT).Methods The study included 82 children who presented with intoeing gait. 3D-CT data taken between 2006 and 2014 were retrospectively reviewed. FAA was measured by 3D-CT. FAA is defined as the angle between the long axis of the femur neck and condylar axis of the distal femur. FAA measurement was performed twice at both lower extremities by each rater. The intra-rater and inter-rater reliability were calculated by intraclass correlation coefficient (ICC). Results One hundred and sixty-four lower limbs of 82 children (31 boys and 51 girls, 6.3±3.2 years old) were included. The ICCs of intra-rater measurement for the angle of femoral neck axis (NA) were 0.89 for rater A and 0.96 for rater B, and those of condylar axis (CA) were 0.99 for rater A and 0.99 for rater B, respectively. The ICC of inter-rater measurement for the angle of NA was 0.89 and that of CA was 0.92. By each rater, the ICCs of the intra-rater measurement for FAA were 0.97 for rater A and 0.95 for rater B, respectively and the ICC of the inter-rater measurement for FAA was 0.89. Conclusion The 3D-CT measures for FAA are reliable within individual raters and between different raters. The 3D-CT measures of FAA can be a useful method for accurate diagnosis and follow-up of femoral anteversion.
참고문헌 (20)
- Kling TF Jr, "Angular and torsional deformities of the lower limbs in children", Clin Orthop Relat Res, 176, pp.136~147 (1983)
- Kumar SJ, "Torsional abnormalities in children’s lower extremities", Orthop Clin North Am, 13, pp.629~639 (1982)
- Cibulka MT, "Determination and significance of femoral neck anteversion", Phys Ther, 84, pp.550~558 (2004)
- Bobroff ED, "Femoral anteversion and neck-shaft angle in children with cerebral palsy", Clin Orthop Relat Res, 364, pp.194~204 (1999)
- Gelberman RH, "Femoral anteversion. A clinical assessment of idiopathic intoeing gait in children", J Bone Joint Surg Br, 69, pp.75~79 (1987)
- Lee DY, "A new method for measurement of femoral anteversion: a comparative study with other radiographic methods", Int Orthop, 16, pp.277~281 (1992)
- Anda S, "Femoral anteversion measured by ultrasonography and radiography: an anatomic investigation", Acta Radiol, 29, pp.695~699 (1988)
- Guenther KP, "Measurement of femoral anteversion by magnetic resonance imaging: evaluation of a new technique in children and adolescents", Eur J Radiol, 21, pp.47~52 (1995)
- 이소영, "Physical Examination and Computed Tomography in Children with Toe in Gait", Annals of Rehabilitation Medicine, 35(1), pp.61~66 (2011), 대한재활의학회
- Hyun Dong Kim, "Relationship between Physical Examinations and Two-Dimensional Computed Tomographic Findings in Children with Intoeing Gait", Annals of Rehabilitation Medicine, 35(4), pp.491~498 (2011), 대한재활의학회
- Weiner DS, "Computed tomography in the measurement of femoral anteversion", Orthopedics, 1, pp.299~306 (1978)
- Miller F, "Measuring anteversion and femoral neck-shaft angle in cerebral palsy", Dev Med Child Neurol, 39, pp.113~118 (1997)
- Gose S, "Morphometric analysis of the femur in cerebral palsy: 3-dimensional CT study", J Pediatr Orthop, 30, pp.568~574 (2010)
- Kim SI, "Measurement of femoral anteversion using 3 dimensional imaging", J Korean Acad Rehabil Med, 18, pp.495~499 (1994)
- Flohr TG, "Multi-detector row CT systems and image-reconstruction techniques", Radiology, 235, pp.756~773 (2005)
- Rengier F, "3D printing based on imaging data: review of medical applications", Int J Comput Assist Radiol Surg, 5, pp.335~341 (2010)
- Kim JS, "Measurement of femoral neck anteversion in 3D. Part 1: 3D imaging method", Med Biol Eng Comput, 38, pp.603~609 (2000)
- Flohr TG, "Multi-detector row CT systems and image-reconstruction techniques", Radiology, 235, pp.756~773 (2005)
- Riccio AI, "Three-dimensional computed tomography for determination of femoral anteversion in a cerebral palsy model", J Pediatr Orthop, 35, pp.167~171 (2015)
- Pearce MS, "Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study", Lancet, 380, pp.499~505 (2012)
