Objective To assess the intra-rater and inter-rater reliability for measuring tibial torsion measurements by a radiographic method using three-dimensional computed tomography reconstruction (3D-CT) and to compare the physical measures to those of 3D-CT. Method The study included 33 children who presented with intoeing gait. Tibial torsion was measured by 3D-CT. Distal reference point was the bimalleolar axis. Proximal reference points were the transtibial axis and posterior condylar axis. Physical measurements included thigh-foot angle (TFA) and bimalleolar angle (BMA). 3D-CT measurement and physical measurement were performed twice at both lower extremities by each rater. The intra-rater and inter-rater reliability were calculated by intraclass correlation coeffi ciency (ICC). Th e relationship between radiological and physical examination was calculated by Spearman correlation coefficient. Results The 3D-CT measures for tibial torsion were reliable within individual raters and between different raters. However, physical measures for tibial torsion were reliable within an individual rater but not reliable between raters. The 3D-CT measures by any proximal reference axis were more reliable within a rater and between raters than physical measurements. There was no signifi cant impact introduced by the selection of the proximal reference axis. The correlation coeffi ciency between 3D-CT and physical measurement methods was low. Conclusion Because the 3D-CT measurements for tibial torsion are more reliable than physical measurements, we recommend that accurate diagnosis of internal tibial torsion should be detected by using 3D-CT measurements. Also, considering the disadvantages of radiological measurements, physical measurement may be used for short term follow-up by same raters, as intra-rater reliability is relatively good.
Abstract
Objective To assess the intra-rater and inter-rater reliability for measuring tibial torsion measurements by a radiographic method using three-dimensional computed tomography reconstruction (3D-CT) and to compare the physical measures to those of 3D-CT. Method The study included 33 children who presented with intoeing gait. Tibial torsion was measured by 3D-CT. Distal reference point was the bimalleolar axis. Proximal reference points were the transtibial axis and posterior condylar axis. Physical measurements included thigh-foot angle (TFA) and bimalleolar angle (BMA). 3D-CT measurement and physical measurement were performed twice at both lower extremities by each rater. The intra-rater and inter-rater reliability were calculated by intraclass correlation coeffi ciency (ICC). Th e relationship between radiological and physical examination was calculated by Spearman correlation coefficient. Results The 3D-CT measures for tibial torsion were reliable within individual raters and between different raters. However, physical measures for tibial torsion were reliable within an individual rater but not reliable between raters. The 3D-CT measures by any proximal reference axis were more reliable within a rater and between raters than physical measurements. There was no signifi cant impact introduced by the selection of the proximal reference axis. The correlation coeffi ciency between 3D-CT and physical measurement methods was low. Conclusion Because the 3D-CT measurements for tibial torsion are more reliable than physical measurements, we recommend that accurate diagnosis of internal tibial torsion should be detected by using 3D-CT measurements. Also, considering the disadvantages of radiological measurements, physical measurement may be used for short term follow-up by same raters, as intra-rater reliability is relatively good.
참고문헌 (15)
- Kumar SJ, "Torsional abnormalities in children's lower extremities", Orthop Clin North Am, 13, pp.629~639 (1982)
- Staheli LT, "Lower-ex- tremity rotational problems in children. Normal values to guide management", J Bone Joint Surg Am, 67, pp.39~47 (1985)
- Eckhoff DG, "Three-dimensional computed tomography reconstruction of tibial torsion", Clin Orthop Relat Res, 302, pp.42~46 (1994)
- Soyoung Lee, "Physical Examination and Computed Tomography in Children with Toe in Gait", Annals of Rehabilitation Medicine, 35(1), pp.61~66 (2011), 대한재활의학회
- Stuberg W, "Measurement of tibial torsion and thigh-foot angle using goniometry and computed tomography", Clin Orthop Relat Res, 272, pp.208~212 (1991)
- Valmassy R, "Tibial torsion. Normal values in children", J Am Podiatr Med Assoc, 79, pp.432~435 (1989)
- Milner CE, "A comparison of four in vivo methods of measuring tibial torsion", J Anat, 193, pp.139~144 (1998)
- Jakob RP, "Tibial torsion calculated by computerised tomography and compared to other methods of measurement", J Bone Joint Surg Br, 62, pp.238~242 (1980)
- Lee SH, "Tibial Torsion in Cerebral Palsy: Validity and Reliability of Measurement", CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 467, pp.2098~2104 (2009), LIPPINCOTT WILLIAMS WILLKINS Ltd
- Winter WG Jr, "The skiing sequelae of tibial torsion", Orthop Clin North Am, 7, pp.231~240 (1976)
- Clementz BG, "Assessment of tibial torsion and rotational deformity with a new fluoroscopic technique", Clin Orthop Relat Res, 245, pp.199~209 (1989)
- Guven M, "A new radiographic measurement method for evaluation of tibial torsion: a pilot study in adults", Clin Orthop Relat Res, 467, pp.1807~1812 (2009)
- Jend HH, "Measurement of tibial torsion by computer tomography", Acta Radiol Diagn, 22, pp.271~276 (1981)
- Abel MF, "Evaluation of CT scans and 3-D reformatted images for quantitative assessment of the hip", J Pediatr Orthop, 14, pp.48~53 (1994)
- Kim SI, "Measurement of femoral anteversion using 3 dimensional imaging", J Korean Acad Rehab Med, 18, pp.495~499 (1994)