본문 바로가기
KERD
논문KCI 등재

Two-dimensional shear wave elastography for assessing liver fibrosis in patients with chronic liver disease: a prospective cohort study

2

조회

0

다운로드

4

인용

0

참고문헌

키워드

주제분류내과학

초록

Background/Aims: The objective of this study was to determine whether the newly developed two-dimensional shear wave elastography (2D-SWE, RS85, Samsung-shearwave imaging) was more valid and reliable than transient elastography (TE) for predicting the stage of liver fibrosis. Methods: The study prospectively enrolled a total of 116 patients with chronic liver disease who underwent 2D-SWE, TE, laboratory testing, and liver biopsy on the same day from two tertiary care hospitals. One patient with unreliable measurement was excluded. The measurement of 2D-SWE was considered acceptable when a homogenous color pattern in a region of interest of at least 10 mm was detected at 10 different sites. Diagnostic performance was calculated using area under the receiver operating characteristic curve (AUROC). Results: Liver fibrosis stages included F0 (18%), F1 (19%), F2 (24%), F3 (22%), and F4 (17%). Interclass correlation coefficient for inter-observer agreement in 2D-SWE was 0.994 (95% confidence interval [CI], 0.988 to 0.997). Overall, the results of 2D-SWE and stages of histological fibrosis were significantly correlated (r = 0.601, p < 0.001). For The 2D-SWE showed good diagnostic ability (AUROC, 0.851; 95% CI, 0.773 to 0.911) comparable to TE (AUROC, 0.859; 95% CI, 0.781 to 0.916) for the diagnosis of significant fibrosis (≥ F2), and the cut-off value was 5.8 kPa. AUROC and optimal cut-off of 2D-SWE for the diagnosis of liver cirrhosis were 0.889 (95% CI, 0.817 to 0.940) and 9.6 kPa, respectively. TE showed similar diagnostic performance in distinguishing cirrhosis (AUROC, 0.938; 95% CI, 0.877 to 0.974; p = 0.08). Conclusions: 2D-SWE is comparable to TE in diagnosing significant fibrosis and liver cirrhosis with high reliability.

Abstract

Background/Aims: The objective of this study was to determine whether the newly developed two-dimensional shear wave elastography (2D-SWE, RS85, Samsung-shearwave imaging) was more valid and reliable than transient elastography (TE) for predicting the stage of liver fibrosis. Methods: The study prospectively enrolled a total of 116 patients with chronic liver disease who underwent 2D-SWE, TE, laboratory testing, and liver biopsy on the same day from two tertiary care hospitals. One patient with unreliable measurement was excluded. The measurement of 2D-SWE was considered acceptable when a homogenous color pattern in a region of interest of at least 10 mm was detected at 10 different sites. Diagnostic performance was calculated using area under the receiver operating characteristic curve (AUROC). Results: Liver fibrosis stages included F0 (18%), F1 (19%), F2 (24%), F3 (22%), and F4 (17%). Interclass correlation coefficient for inter-observer agreement in 2D-SWE was 0.994 (95% confidence interval [CI], 0.988 to 0.997). Overall, the results of 2D-SWE and stages of histological fibrosis were significantly correlated (r = 0.601, p < 0.001). For The 2D-SWE showed good diagnostic ability (AUROC, 0.851; 95% CI, 0.773 to 0.911) comparable to TE (AUROC, 0.859; 95% CI, 0.781 to 0.916) for the diagnosis of significant fibrosis (≥ F2), and the cut-off value was 5.8 kPa. AUROC and optimal cut-off of 2D-SWE for the diagnosis of liver cirrhosis were 0.889 (95% CI, 0.817 to 0.940) and 9.6 kPa, respectively. TE showed similar diagnostic performance in distinguishing cirrhosis (AUROC, 0.938; 95% CI, 0.877 to 0.974; p = 0.08). Conclusions: 2D-SWE is comparable to TE in diagnosing significant fibrosis and liver cirrhosis with high reliability.

참고문헌 (28)

  1. Marcellin P, "Liver diseases: a major, neglected global public health problem requiring urgent actions and largescale screening", Liver Int, 38(Suppl 1), pp.2~6 (2018)
  2. Suk KT, "Staging of liver fibrosis or cirrhosis : the role of hepatic venous pressure gradient measurement", World J Hepatol, 7, pp.607~615 (2015)
  3. Horowitz JM, "a review from the society of abdominal radiology disease focus panel", Abdom Radiol(NY), 42, pp.2037~2053 (2017)
  4. Boyum JH, "Incidence and risk factors for adverse events related to image-guided liver biopsy", Mayo Clin Proc, 91, pp.329~335 (2016)
  5. Bedossa P, "Histologic and noninvasive estimates of liver fibrosis", Clin Liver Dis(Hoboken), 6, pp.5~8 (2015)
  6. Wai CT, "A simple noninvasive index can predict both significant fibrosis and cirrhosis in patients with chronic hepatitis C", Hepatology, 38, pp.518~526 (2003)
  7. Vallet-Pichard A, "FIB-4 : an inexpensive and accurate marker of fibrosis in HCV infection : comparison with liver biopsy and fibrotest", Hepatology, 46, pp.32~36 (2007)
  8. Lok AS, "Predicting cirrhosis in patients with hepatitis C based on standard laboratory tests : results of the HALT-C cohort", Hepatology, 42, pp.282~292 (2005)
  9. Foschi FG, "Is there an association between commonly employed biomarkers of liver fibrosis and liver stiffness in the general population?", Ann Hepatol, 19, pp.380~387 (2020)
  10. Papastergiou V, "Non-invasive assessment of liver fibrosis", Ann Gastroenterol, 25, pp.218~231 (2012)
  11. Giuffre M, "Evaluation of spleen stiffness in healthy volunteers using point shear wave elastography", Ann Hepatol, 18, pp.736~741 (2019)
  12. Rockey DC, "Noninvasive measures of liver fibrosis", Hepatology, 43(2 Suppl 1), pp.S113~S120 (2006)
  13. Abraldes JG, "Noninvasive tools and risk of clinically significant portal hypertension and varices in compensated cirrhosis : the"Anticipate"study", Hepatology, 64, pp.2173~2184 (2016)
  14. Sigrist RM, "Ultrasound elastography : review of techniques and clinical applications", Theranostics, 7, pp.1303~1329 (2017)
  15. Barr RG, "Elastography assessment of liver fibrosis : Society of Radiologists in Ultrasound Consensus Conference Statement", Radiology, 276, pp.845~861 (2015)
  16. Dhyani M, "Validation of shear wave elastography cutoffvalues on the supersonic Aixplorer for practical clinical use in liver fibrosis staging", Ultrasound Med Biol, 43, pp.1125~1133 (2017)
  17. Zheng J, "Two-dimensional shear-wave elastography and conventional US : the optimal evaluation of liver fibrosis and cirrhosis", Radiology, 275, pp.290~300 (2015)
  18. Guibal A, "Shear wave elastography : an accurate technique to stage liver fibrosis in chronic liver diseases", Diagn Interv Imaging, 97, pp.91~99 (2016)
  19. 유정인, "Assessment of liver fibrosis using 2-dimensional shear wave elastography: a prospective study of intra- and interobserver repeatability and comparison with point shear wave elastography", ULTRASONOGRAPHY, 39(1), pp.52~59 (2020), 대한초음파의학회
  20. Rockey DC, "Liver biopsy", Hepatology, 49, pp.1017~1044 (2009)
  21. Bedossa P, "An algorithm for the grading of activity in chronic hepatitis C. The METAVIR Cooperative Study Group", Hepatology, 24, pp.289~293 (1996)
  22. Nguyen P, "NonbinROC : software for evaluating diagnostic accuracies with non-binary gold standards", J Stat Softw, 21, pp.1~10 (2007)
  23. Lambert J, "How to measure the diagnostic accuracy of noninvasive liver fibrosis indices : the area under the ROC curve revisited", Clin Chem, 54, pp.1372~1378 (2008)
  24. Sporea I, "Which are the cut-offvalues of 2D-Shear Wave Elastography(2D-SWE)liver stiffness measurements predicting different stages of liver fibrosis, considering transient elastography(TE)as the reference method", Eur J Radiol, 83, pp.e118~e122 (2014)
  25. Zeng J, "Diagnostic accuracy of 2-D shear wave elastography for the non-invasive staging of liver fibrosis in patients with elevated alanine aminotransferase levels", Ultrasound Med Biol, 44, pp.85~93 (2018)
  26. Castera L, "Prospective comparison of transient elastography, fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C", Gastroenterology, 128, pp.343~350 (2005)
  27. Fraquelli M, "Reproducibility of transient elastography in the evaluation of liver fibrosis in patients with chronic liver disease", Gut, 56, pp.968~973 (2007)
  28. Castera L, "Non-invasive evaluation of liver fibrosis using transient elastography", J Hepatol, 48, pp.835~847 (2008)

관련 논문AI추천

Combi-Elastography versus Transient Elastography for Assessing the Histological Severity of Metabolic Dysfunction-Associated Steatotic Liver Disease소영호, Chang Mee Soo, Jang Heejoon, Jang Siwon, Joo Sae Kyung, Kim Won, Lee Dong Ho, Lee Dong Hyeon, Lee Yun Kyu, Park Jeong Hwan거트앤리버 소화기연관학회협의회 · Gut and Liver2024 · 제18권 제6호The usefulness of transient elastography, acoustic-radiation- force impulse elastography, and real-time elastography for the evaluation of liver fibrosis김상균, 김영석, 김홍수, 안형수, 이세환, 이윤나, 장재영, 정승원, Boo Sung Kim, Jong Ho Chung대한간학회 · Clinical and Molecular Hepatology2013 · 제19권 제2호Combination of Transient Elastography and an Enhanced Liver Fibrosis Test to Assess the Degree of Liver Fibrosis in Patients with Chronic Hepatitis B김도영, 김범경, 김승업, 박준용, 안상훈, 한광협, Hyon-Suk Kim, Ja Yoon Heo, Kijun Song, Young Nyun Park거트앤리버 소화기연관학회협의회 · Gut and Liver2018 · 제12권 제2호Vibration-controlled transient elastography for significant fibrosis in treatment- naïve chronic hepatitis B patients: A systematic review and meta-analysisDae Won Jun, Eun Hwa Kim, Han Ah Lee, Hee Yeon Kim, Jihyun An, Ji Won Han, Jung Hwan Yu, Mi Na Kim, Miyoung Choi, Seung Up Kim, Young Eun Chon, Young-Joo Jin대한간학회 · Clinical and Molecular Hepatology2024 · 제30권 제1호횡파 탄성초음파를 이용한 비침습적 간섬유화 검사한지원대한내과학회 · 대한내과학회지2025 · 제100권 제1호Factors Influencing the Diagnostic Accuracy of Acoustic Radiation Force Impulse Elastography in Patients with Chronic Hepatitis B조몽, 권영오, 김도영, 김범경, 김선욱, 김승업, 박미성, 박수영, 박준용, 안상훈, 윤기태, 탁원영, 한광협거트앤리버 소화기연관학회협의회 · Gut and Liver2016 · 제10권 제2호

이 간행물의 다른 논문 (27건)