Objective: To establish the reference standard of the median nerve conduction study (NCS) in Korea.Methods: A total of 648 median motor and 602 median sensory NCSs from 349 Korean healthy volunteers were tested and analyzed prospectively. Equipment calibration, assessment of intraand inter-rater reliability, and the NCSs per se were conducted according to a predetermined protocol. A reference standard was established from uncertainty components for the following parameters: the onset and peak latencies; the baseline-to-peak and peak-to-peak amplitudes; the area and duration of the negative wave; and the nerve conduction velocity. The effects of sex, age and stimulation intensity were analyzed.Results: Each measured value of 648 median motor and 602 median sensory nerves were obtained and presented with both mean and expanded uncertainties, as well as mean and standard deviations. The cut-off values with expanded uncertainty were determined for different age and sex groups. After adjusting for anthropometric covariates, all parameters except duration were affected by age, and sex appeared to influence both duration and area. While stimulation intensity significantly affected some parameters including latencies, the effect sizes were negligible.Conclusion: We propose the median NCS reference standard using the largest Korean dataset ever available. The use of the traceable and reliable reference standard is anticipated to promote more accurate and dependable diagnosis and appropriate management of median neuropathies in Korea.

Abstract

Objective: To establish the reference standard of the median nerve conduction study (NCS) in Korea.Methods: A total of 648 median motor and 602 median sensory NCSs from 349 Korean healthy volunteers were tested and analyzed prospectively. Equipment calibration, assessment of intraand inter-rater reliability, and the NCSs per se were conducted according to a predetermined protocol. A reference standard was established from uncertainty components for the following parameters: the onset and peak latencies; the baseline-to-peak and peak-to-peak amplitudes; the area and duration of the negative wave; and the nerve conduction velocity. The effects of sex, age and stimulation intensity were analyzed.Results: Each measured value of 648 median motor and 602 median sensory nerves were obtained and presented with both mean and expanded uncertainties, as well as mean and standard deviations. The cut-off values with expanded uncertainty were determined for different age and sex groups. After adjusting for anthropometric covariates, all parameters except duration were affected by age, and sex appeared to influence both duration and area. While stimulation intensity significantly affected some parameters including latencies, the effect sizes were negligible.Conclusion: We propose the median NCS reference standard using the largest Korean dataset ever available. The use of the traceable and reliable reference standard is anticipated to promote more accurate and dependable diagnosis and appropriate management of median neuropathies in Korea.

참고문헌 (40)

  1. Dumitru D, "Electrodiagnostic medicine", pp.159~223 (2002), Hanley & Belfus
  2. Dorfman LJ, "Age-related changes in peripheral and central nerve conduction in man", Neurology, 29, pp.38~44 (1979)
  3. Robinson LR, "Influences of height and gender on normal nerve conduction studies", Arch Phys Med Rehabil, 74, pp.1134~1138 (1993)
  4. Kouyoumdjian JA, "Influence of temperature on comparative nerve conduction techniques for carpal tunnel syndrome diagnosis", Arq Neuropsiquiatr, 63, pp.422~426 (2005)
  5. Kommalage M, "Influence of age, gender, and sidedness on ulnar nerve conduction", J Clin Neurophysiol, 30, pp.98~101 (2013)
  6. Benatar M, "Reference data for commonly used sensory and motor nerve conduction studies", Muscle Nerve, 40, pp.772~794 (2009)
  7. American Association Of Electrodiagnostic Medicine, "Guidelines in electrodiagnostic medicine", Muscle Nerve, 15, pp.229~253 (1992)
  8. Bolton CF, "Minimum standards for electromyography in Canada : a statement of the Canadian Society of Clinical Neurophysiologists", Can J Neurol Sci, 27, pp.288~291 (2000)
  9. Sohn MK, "An evidence-based electrodignositc guideline for the diagnosis of radiculopathy", J Korean Assoc EMG Electrodiagn Med, 14, pp.1~9 (2012)
  10. Awang MS, "Nerve conduction study of healthy Asian Malays : the influence of age on median, ulnar, and sural nerves", Med Sci Monit, 13, pp.CR330~2 (2007)
  11. Pawar SM, "Normative data of upper limb nerve conduction in Central India", Indian J Physiol Pharmacol, 55, pp.241~245 (2011)
  12. Owolabi LF, "Median nerve conduction in healthy Nigerians : normative data", Ann Med Health Sci Res, 6, pp.85~89 (2016)
  13. Ryan CS, "Nerve conduction normal values for electrodiagnosis in pediatric patients", Muscle Nerve, 60, pp.155~160 (2019)
  14. Dillingham T, "Establishing high-quality reference values for nerve conduction studies : a report from the Normative Data Task Force of the American Association Of Neuromuscular & Electrodiagnostic Medicine", Muscle Nerve, 54, pp.366~370 (2016)
  15. Chen S, "Electrodiagnostic reference values for upper and lower limb nerve conduction studies in adult populations", Muscle Nerve, 54, pp.371~377 (2016)
  16. BIPM, "International vocabulary of metrology - Basic and general concepts and associated terms (VIM)", pp.1~91 (2012), Joint Committee for Guides on Metrology
  17. Fraser CG, "Proposals for setting generally applicable quality goals solely based on biology", Ann Clin Biochem, 34(Pt 1), pp.8~12 (1997)
  18. Dorwart WV, "Comparison of methods for calculating serum osmolality form chemical concentrations, and the prognostic value of such calculations", Clin Chem, 21, pp.190~194 (1975)
  19. Bhagat CI, "Calculated vs measured plasma osmolalities revisited", Clin Chem, 30, pp.1703~1705 (1984)
  20. Levey AS, "Using standardized serum creatinine values in the modification of diet in renal disease study equation for estimating glomerular filtration rate", Ann Intern Med, 145, pp.247~254 (2006)
  21. Levey AS, "A more accurate method to estimate glomerular filtration rate from serum creatinine : a new prediction equation. Modification of Diet in Renal Disease Study Group", Ann Intern Med, 130, pp.461~470 (1999)
  22. Florkowski CM, "Methods of estimating GFR-different equations including CKD-EPI", Clin Biochem Rev, 32, pp.75~79 (2011)
  23. Jones GR, "Estimating renal function for drug dosing decisions", Clin Biochem Rev, 32, pp.81~88 (2011)
  24. Chae HJ, "Ulnar nerve conduction studies : reference standards with extended uncertainty in healthy South Korean adults", J Electrodiagn Neuromuscul Dis, 23, pp.1~10 (2021)
  25. Kim JY, "Reference standards for nerve conduction studies of individual nerves of lower extremity with expanded uncertainty in healthy Korean adults", Ann Rehabil Med, 46, pp.9~23 (2022)
  26. "medical procedures statistics" (2010)[URL]
  27. Buschbacher RM, "Median nerve motor conduction to the abductor pollicis brevis", Am J Phys Med Rehabil, 78(6 Suppl), pp.S1~S8 (1999)
  28. Lee HJ, "Nerve conduction studies of median motor nerve and median sensory branches according to the severity of carpal tunnel syndrome", Ann Rehabil Med, 37, pp.254~262 (2013)
  29. Working Group 1 of the Joint Committee for Guides in Metrology, "Evaluation of measurement data — Guide to the expression of uncertainty in measurement", Joint Committee for Guides on Metrology, 1~120 (2008)
  30. Hahn MS, "A study on the conduction veloctiy of the median and ulnar nerves in healthy Korean", J Korean Orthop Assoc, 17, pp.575~587 (1982)
  31. Lee KY, "The usefulness of standardization of the nerve conduction study in the diagnosis and follow up of the demyelinating polyneuropathy", J Korean Neurol Assoc, 16, pp.510~518 (1998)
  32. Lee KM, "Estimation of reference values of median nerve conduction study : a meta-analysis", J Korean Acad Rehabil Med, 26, pp.717~727 (2002)
  33. NORRIS AH, "Age changes in the maximum conduction velocity of motor fibers of human ulnar nerves", J Appl Physiol, 5, pp.589~593 (1953)
  34. WAGMAN IH, "Maximum conduction velocities of motor fibers of ulnar nerve in human subjects of various ages and sizes", J Neurophysiol, 15, pp.235~244 (1952)
  35. Di Benedetto M, "Evoked sensory potentials in peripheral neuropathy", Arch Phys Med Rehabil, 53, pp.126~131 (1972)
  36. Stetson DS, "Effects of age, sex, and anthropometric factors on nerve conduction measures", Muscle Nerve, 15, pp.1095~1104 (1992)
  37. Moriyama H, "Sex differences in morphometric aspects of the peripheral nerves and related diseases", NeuroRehabilitation, 39, pp.413~422 (2016)
  38. Gøransson LG, "The effect of age and gender on epidermal nerve fiber density", Neurology, 62, pp.774~777 (2004)
  39. Meh D, "Quantitative assessment of thermal and pain sensitivity", J Neurol Sci, 127, pp.164~169 (1994)
  40. Yan Z, "Sexually dimorphic neurotransmitter release at the neuromuscular junction in adult caenorhabditis elegans", Front Mol Neurosci, 14, pp.780396~ (2022)

관련 논문AI추천

한국인에서 불확도를 고려한 척골신경전도검사의 참조 표준치김은경, 박지홍, 오병모, 이구주, 이상윤, 이시욱, 이재현, 임재영, 정선근, 채현준대한근전도전기진단의학회 · 대한근전도 전기진단의학회지2021 · 제23권 제1호Reference Standards for Nerve Conduction Studies of Individual Nerves of Lower Extremity With Expanded Uncertainty in Healthy Korean Adults김기원, 김은경, 오병모, 이재현, Goo Joo Lee, Hyung Seok Shim, Jaewon Beom, Jae Yoon Kim, Jae-Young Lim, Sang Yoon Lee, Shi-Uk Lee, Sun Gun Chung대한재활의학회 · Annals of Rehabilitation Medicine2022 · 제46권 제1호한국인의 노인 인구에서 연령에 따른 신경전도검사의 특징문재로, 박윤길, 윤여훈, 정철오, 최승호, 최정화대한근전도전기진단의학회 · 대한근전도 전기진단의학회지2011 · 제13권 제2호노인의 신경전도검사에 대한 신장, 연령 및 성별의 영향에 관한 정량적 분석강상국, 김정훈, 김해종, 박노경, 이동국, 이상석, 임정근대한근전도전기진단의학회 · 대한근전도 전기진단의학회지2010 · 제12권 제2호정중 운동신경 전도검사 시 7 cm 근위 자극과 완관절 주름 자극의 비교김형진, 신창혁, 이베나, 이원일, 이진영대한재활의학회 · Annals of Rehabilitation Medicine2008 · 제32권 제1호메타 분석을 이용한 정중신경 전도검사의 정상 참고치라윤주, 이경무대한재활의학회 · Annals of Rehabilitation Medicine2002 · 제26권 제6호

이 간행물의 다른 논문 (6건)