Echocardiographic Classification of Perimembranous Ventricular Septal Defect Guides Selection of the Occluder Design for Their Transcatheter Device Closure
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
BACKGROUND: Perimembranous ventricular septal defects (VSDs) has proximate relation to the aortic and tricuspid valves as well as the conduction tissues. Transcatheter closure utilizes various off-label device designs. METHODS: Perimembranous VSD without aortic margin were classified as group A, with thick aortic margin as group B, with membranous septal aneurysm as group C and defects restricted by tricuspid valve attachments as group D. The proposed ideal design was asymmetric device in group A; duct occluder I (ADOI) and muscular ventricular septal occluder (MVSO) in group B; thin profile duct occluder II (ADOII) in group C and ADOI in group D. Device was 0–2 mm larger than the defect. RESULTS: Eighty patients with VSD measuring 6.83 ± 2.87mm underwent successful closure. Device was retrieved before release in one group A and one group C patient due to aortic regurgitation. Asymmetric device was used in 16 group A defects. Among group B defects, ADOI was used in 5, ADOII in 5, MVSO in one and asymmetric device in 3. Group C defects were closed with ADOI in 7, ADOII in 10 and asymmetric device in 3. Three patients with multiple exits had 2 ADOII devices. Group D defects were closed using ADOI in 20 and ADOII in 10 patients. There was no late aortic regurgitation or heart block on a follow-up exceeding 7 years. CONCLUSIONS: This echocardiographic classification helps device selection in every single patient. While asymmetric device is uniquely suited for group A defects, different designs are appropriate in the other groups.
Abstract
BACKGROUND: Perimembranous ventricular septal defects (VSDs) has proximate relation to the aortic and tricuspid valves as well as the conduction tissues. Transcatheter closure utilizes various off-label device designs. METHODS: Perimembranous VSD without aortic margin were classified as group A, with thick aortic margin as group B, with membranous septal aneurysm as group C and defects restricted by tricuspid valve attachments as group D. The proposed ideal design was asymmetric device in group A; duct occluder I (ADOI) and muscular ventricular septal occluder (MVSO) in group B; thin profile duct occluder II (ADOII) in group C and ADOI in group D. Device was 0–2 mm larger than the defect. RESULTS: Eighty patients with VSD measuring 6.83 ± 2.87mm underwent successful closure. Device was retrieved before release in one group A and one group C patient due to aortic regurgitation. Asymmetric device was used in 16 group A defects. Among group B defects, ADOI was used in 5, ADOII in 5, MVSO in one and asymmetric device in 3. Group C defects were closed with ADOI in 7, ADOII in 10 and asymmetric device in 3. Three patients with multiple exits had 2 ADOII devices. Group D defects were closed using ADOI in 20 and ADOII in 10 patients. There was no late aortic regurgitation or heart block on a follow-up exceeding 7 years. CONCLUSIONS: This echocardiographic classification helps device selection in every single patient. While asymmetric device is uniquely suited for group A defects, different designs are appropriate in the other groups.
참고문헌 (18)
- Penny DJ, "Ventricular septal defect", Lancet, 377, pp.1103~1112 (2011)
- Ho SY, "Morphology of perimembranous ventricular septal defects : implications for transcatheter device closure", J Interv Cardiol, 17, pp.99~108 (2004)
- Butera G, "Transcatheter closure of perimembranous ventricular septal defects : early and long-term results", J Am Coll Cardiol, 50, pp.1189~1195 (2007)
- Yang J, "Transcatheter versus surgical closure of perimembranous ventricular septal defects in children : a randomized controlled trial", J Am Coll Cardiol, 63, pp.1159~1168 (2014)
- Chen Q, "Comparison of transthoracic device closure and surgical repair with right submammary or right infra-axillary thoracotomy for perimembranous VSD", Thorac Cardiovasc Surg, 67, pp.8~13 (2019)
- Dai XF, "A comparative study of minimal lower-sternal incision device closure, minimal right thoracic incision device closure, and midsternal open repair of isolated perimembranous VSD, a retrospective cohort study", Int J Cardiol, 306, pp.15~19 (2020)
- Predescu D, "Complete heart block associated with device closure of perimembranous ventricular septal defects", J Thorac Cardiovasc Surg, 136, pp.1223~1228 (2008)
- Sivakumar K, "Textbook of Echocardiography", pp.474~503 (2018), Jaypee Publishers
- Carminati M, "Transcatheter closure of congenital ventricular septal defects : results of the European Registry", Eur Heart J, 28, pp.2361~2368 (2007)
- Lee SM, "Transcatheter closure of perimembranous ventricular septal defect using Amplatzer ductal occluder", Catheter Cardiovasc Interv, 82, pp.1141~1146 (2013)
- Kanaan M, "Follow-up of patients with interventional closure of ventricular septal defects with Amplatzer duct occluder II", Pediatr Cardiol, 36, pp.379~385 (2015)
- Lytrivi ID, "Normal values for left ventricular volume in infants and young children by the echocardiographic subxiphoid five-sixth area by length(bullet)method", J Am Soc Echocardiogr, 24, pp.214~218 (2011)
- Bergmann M, "Short-and long-term outcome after interventional VSD closure : a single-center experience in pediatric and adult patients", Pediatr Cardiol, 42, pp.78~88 (2020)
- Saurav A, "Comparison of percutaneous device closure versus surgical closure of peri-membranous ventricular septal defects : a systematic review and meta-analysis", Catheter Cardiovasc Interv, 86, pp.1048~1056 (2015)
- Li G, "Re-evaluation of the criteria for asymmetric amplatzer occluders in the closure of perimembranous ventricular septal defects: a case series report", Medicine (Baltimore), 99, pp.e21356~ (2020)
- Li H, "Short-and medium-term follow-up of transcatheter closure of perimembranous ventricular septal defects", BMC Cardiovasc Disord, 19, pp.222~ (2019)
- Li D, "Comparisons of perventricular device closure, conventional surgical repair, and transcatheter device closure in patients with perimembranous ventricular septal defects: a network meta-analysis", BMC Surg, 20, pp.115~ (2020)
- Haddad RN, "Device closure of perimembranous ventricular septal defect : Choosing between Amplatzer occluders", Front Pediatr, 7, pp.300~ (2019)