BACKGROUND: Transcatheter device closure of ventricular septal defect (VSD) has becomean attractive alternative to surgery. We report here on our early experiences of transcatheterclosure of VSD using Cocoon devices, which are now available in Korea. METHODS: We reviewed the medical records and angiographic images of 13 patients whounderwent transcatheter closure of VSD with a Cocoon occluder at Samsung Medical Center. The median patient age was 5.8 years, and the median patient weight was 20.3 kg. RESULTS: The device was successfully implanted in all patients. The follow-up period was 10± 6 months, and no mortality was observed. An immediate residual leak on the next day wasdetected in 7 patients (including 4 with perimembranous VSD). However, 6 months later, aresidual leak was observed only in 2 patients with perimembranous VSD and 1 patient withmuscular VSD. Early conduction abnormalities were observed in 3 patients, all of whom hadperimembranous VSD, but no significant complete atrioventricular block was observed. One patient experienced newly developed significant aortic regurgitation that decreasedspontaneously but still existed at the 6 month follow-up. No hemolysis or embolization wasnoted on the next day or during the follow-up period. CONCLUSIONS: Cocoon devices can be used safely and effectively for VSD closure. However,residual leaks and conduction abnormalities may occur early after implantation, especially inpatients with perimembranous VSD. Although normal conduction was recovered, long-termevaluation remains essential.
Abstract
BACKGROUND: Transcatheter device closure of ventricular septal defect (VSD) has becomean attractive alternative to surgery. We report here on our early experiences of transcatheterclosure of VSD using Cocoon devices, which are now available in Korea. METHODS: We reviewed the medical records and angiographic images of 13 patients whounderwent transcatheter closure of VSD with a Cocoon occluder at Samsung Medical Center. The median patient age was 5.8 years, and the median patient weight was 20.3 kg. RESULTS: The device was successfully implanted in all patients. The follow-up period was 10± 6 months, and no mortality was observed. An immediate residual leak on the next day wasdetected in 7 patients (including 4 with perimembranous VSD). However, 6 months later, aresidual leak was observed only in 2 patients with perimembranous VSD and 1 patient withmuscular VSD. Early conduction abnormalities were observed in 3 patients, all of whom hadperimembranous VSD, but no significant complete atrioventricular block was observed. One patient experienced newly developed significant aortic regurgitation that decreasedspontaneously but still existed at the 6 month follow-up. No hemolysis or embolization wasnoted on the next day or during the follow-up period. CONCLUSIONS: Cocoon devices can be used safely and effectively for VSD closure. However,residual leaks and conduction abnormalities may occur early after implantation, especially inpatients with perimembranous VSD. Although normal conduction was recovered, long-termevaluation remains essential.
참고문헌 (23)
- Lee SM, "Transcatheter closure of perimembranous ventricular septal defect using Amplatzer ductal occluder", Catheter Cardiovasc Interv, 82, pp.1141~1146 (2013)
- Diab KA, "Device closure of congenital ventricular septal defects", Congenit Heart Dis, 2, pp.92~103 (2007)
- Butera G, "Percutaneous closure of ventricular septal defects", Cardiol Young, 17, pp.243~253 (2007)
- Janorkar S, "Transcatheter closure of ventricular septal defects using the Rashkind device: initial experience", Catheter Cardiovasc Interv, 46, pp.43~48 (1999)
- Balzer D, "Current status of percutaneous closure of ventricular septal defects", Pediatr Ther, 2, pp.112~ (2012)
- Holzer R, "Device closure of muscular ventricular septal defects using the Amplatzer muscular ventricular septal defect occluder: immediate and mid-term results of a U.S. registry", J Am Coll Cardiol, 43, pp.1257~1263 (2004)
- Fu YC, "Transcatheter device closure of muscular ventricular septal defect", Pediatr Neonatol, 52, pp.3~4 (2011)
- Pedra CA, "Percutaneous closure of perimembranous ventricular septal defects with the Amplatzer device: technical and morphological considerations", Catheter Cardiovasc Interv, 61, pp.403~410 (2004)
- Zuo J, "Results of transcatheter closure of perimembranous ventricular septal defect", Am J Cardiol, 106, pp.1034~1037 (2010)
- Holzer R, "Transcatheter closure of perimembranous ventricular septal defects using the amplatzer membranous VSD occluder: immediate and midterm results of an international registry", Catheter Cardiovasc Interv, 68, pp.620~628 (2006)
- Ghosh S, "Complete heart block following transcatheter closure of perimembranous VSD using amplatzer duct occluder II", Catheter Cardiovasc Interv (2017)
- Ghaderian M, "Efficacy and safety of using amplatzer ductal occluder for transcatheter closure of perimembranous ventricular septal defect in pediatrics", Iran J Pediatr, 25, pp.e386~ (2015)
- Lock JE, "Transcatheter closure of ventricular septal defects", Circulation, 78, pp.361~368 (1988)
- Hijazi ZM, "Catheter closure of perimembranous ventricular septal defects using the new Amplatzer membranous VSD occluder: initial clinical experience", Catheter Cardiovasc Interv, 56, pp.508~515 (2002)
- Yang L, "A systematic review on the efficacy and safety of transcatheter device closure of ventricular septal defects (VSD)", J Interv Cardiol, 27, pp.260~272 (2014)
- Hijazi ZM, "Transcatheter closure of single muscular ventricular septal defects using the amplatzer muscular VSD occluder: initial results and technical considerations", Catheter Cardiovasc Interv, 49, pp.167~172 (2000)
- Kitagawa T, "Techniques and results in the management of multiple ventricular septal defects", J Thorac Cardiovasc Surg, 115, pp.848~856 (1998)
- Saurav A, "Comparison of percutaneous device closure versus surgical closure of peri-membranous ventricular septal defects: A systematic review and meta-analysis", Catheter Cardiovasc Interv, 86, pp.1048~1056 (2015)
- Moodie DS, "Technology Insight: transcatheter closure of ventricular septal defects", Nat Clin Pract Cardiovasc Med, 2, pp.592~596 (2005)
- Santhanam H, "A meta-analysis of transcatheter device closure of perimembranous ventricular septal defect", Int J Cardiol, 254, pp.75~83 (2018)
- Yang R, "Risk factors and outcomes of post-procedure heart blocks after transcatheter device closure of perimembranous ventricular septal defect", JACC Cardiovasc Interv, 5, pp.422~427 (2012)
- Li P, "Arrhythmias after transcatheter closure of perimembranous ventricular septal defects with a modified double-disk occluder: early and long-term results", Heart Vessels, 27, pp.405~410 (2012)
- Zhao LJ, "Postprocedural outcomes and risk factors for arrhythmias following transcatheter closure of congenital perimembranous ventricular septal defect: a single-center retrospective study", Chin Med J (Engl), 130, pp.516~521 (2017)