Accuracy of swimming wearable watches for estimating energy expenditure
0
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
With the recent installation of waterproof function on wearable watches, various sports activities including walking, running and even swimming are monitored. Commercially available swimming wearable watches automatically identified stroke type, swim distance, stroke counts and energy expenditure (EE). Although the accuracy of estimating EE of walking, bilking and activities of daily life on activity monitors have been evaluated, it has not been examined for swimming. Thus, the purpose of the study was to evaluate the accuracy of estimating EE for swimming wearable watches (Apple Watch S2, Apple and Garmin Finex 3HR, Garmin). A total of 78 swimmers aged 20-59 years (female: 48%) participated in the study. All the participants wore Apple and Garmin and completed a set of swimming protocol comprising various speeds (0.4, 0.6, 0.8, 1.0, 1.2 m/s). At each swimming speed they were asked to swim for four minutes. Lap counts, stroke counts and energy expenditure (EE) from the Apple and Garmin were evaluated with the criterion measures. Lap counts and stroke counts were directly counted by the research assistant. The portable respiratory gas analyzer (K4b2, Cosmed, Italy) and a swimming snorkel (Aqua Trainer Snorkel, Cosmed, Italy) was used as the criterion measure of EE. The mean absolute percentage error (MAPE) of lap counting and stroke counts at various swimming speed were within 10% for Apple (lap counts: 0.5-6.1%, stroke counts: 6.2-9.3%) and about 20% for Garmin (lap counts: 0-20.6%, stroke counts: 6.8-17.6%). However, the MAPE of EE was higher for Apple (17.1%-151.7%) than for Garmin (17.9%-32.7%). The accuracy of estimating EE tended to improve with increasing swimming speed for both Apple and Garmin. The EEs from Apple were outside the equivalence zone except for at 1.2 m/s and were overestimated compared to the criteria. On the other hand, EEs from Garmin were within the equivalence zone at all speeds except for 1.2 m/s. In conclusion, Apple and Garmin wearable watches accurately measure lap counts and stroke counts. However, the accuracy of estimating EE are poor at slow to medium swimming speed. Further improvement is needed to estimate energy expenditure of swimming at various speed.
Abstract
With the recent installation of waterproof function on wearable watches, various sports activities including walking, running and even swimming are monitored. Commercially available swimming wearable watches automatically identified stroke type, swim distance, stroke counts and energy expenditure (EE). Although the accuracy of estimating EE of walking, bilking and activities of daily life on activity monitors have been evaluated, it has not been examined for swimming. Thus, the purpose of the study was to evaluate the accuracy of estimating EE for swimming wearable watches (Apple Watch S2, Apple and Garmin Finex 3HR, Garmin). A total of 78 swimmers aged 20-59 years (female: 48%) participated in the study. All the participants wore Apple and Garmin and completed a set of swimming protocol comprising various speeds (0.4, 0.6, 0.8, 1.0, 1.2 m/s). At each swimming speed they were asked to swim for four minutes. Lap counts, stroke counts and energy expenditure (EE) from the Apple and Garmin were evaluated with the criterion measures. Lap counts and stroke counts were directly counted by the research assistant. The portable respiratory gas analyzer (K4b2, Cosmed, Italy) and a swimming snorkel (Aqua Trainer Snorkel, Cosmed, Italy) was used as the criterion measure of EE. The mean absolute percentage error (MAPE) of lap counting and stroke counts at various swimming speed were within 10% for Apple (lap counts: 0.5-6.1%, stroke counts: 6.2-9.3%) and about 20% for Garmin (lap counts: 0-20.6%, stroke counts: 6.8-17.6%). However, the MAPE of EE was higher for Apple (17.1%-151.7%) than for Garmin (17.9%-32.7%). The accuracy of estimating EE tended to improve with increasing swimming speed for both Apple and Garmin. The EEs from Apple were outside the equivalence zone except for at 1.2 m/s and were overestimated compared to the criteria. On the other hand, EEs from Garmin were within the equivalence zone at all speeds except for 1.2 m/s. In conclusion, Apple and Garmin wearable watches accurately measure lap counts and stroke counts. However, the accuracy of estimating EE are poor at slow to medium swimming speed. Further improvement is needed to estimate energy expenditure of swimming at various speed.
참고문헌 (27)
- American College of Sports Medicine, "ACSM’s guidelines for exercise testing and prescription" (2013), Lippincott Williams & Wilkins
- "About workout types" (2017)[URL]
- Baldari, C., "Is the new AquaTrainer® snorkel valid for VO2assessment in swimming?", International Journal of Sports Medicine, 34(04), pp.336~344 (2013)
- Barbosa, T. M., "Evaluation of the energy expenditure in competitive swimming strokes", International Journal of Sports Medicine, 27(11), pp.894~899 (2006)
- Brazeau, A. S., "Accuracy of the SenseWear ArmbandTM during ergocycling", International Journal of Sports Medicine, 32(10), pp.761~764 (2011)
- Case, M. A., "Accuracy of smartphone applications and wearable devices for tracking physical activity data", JAMA, 313(6), pp.625~626 (2015)
- Chowdhury, E. A., "Assessment of laboratory and daily energy expenditure estimates from consumer multi-sensor physical activity monitors", PloS One, 12(2), pp.e0171720~ (2017)
- Craig, A. B., "Relationships of stroke rate, distance per stroke, and velocity in competitive swimming", Med Sci Sports, 11(3), pp.278~283 (1979)
- Dooley, E. E., "Estimating accuracy at exercise intensities: A comparative study of self-monitoring heart rate and physical activity wearable devices", JMIR mHealth and uHealth, 5(3), pp.e34~ (2017)
- Eisenmann, J. C., "Comparative analysis of the Cosmed Quark b2 and K4b2 gas analysis systems during submaximal exercise", Journal of Sports Medicine and Physical Fitness, 43(2), pp.150~ (2003)
- Erdogan, A., "Accuracy of the Polar S810iTM heart rate monitor and the Sensewear Pro ArmbandTM to estimate energy expenditure of indoor rowing exercise in overweight and obese individuals", Journal of Sports Science & Medicine, 9(3), pp.508~ (2010)
- Evenson, K. R., "Systematic review of the validity and reliability of consumer-wearable activity trackers", International Journal of Behavioral Nutrition and Physical Activity, 12(1), pp.159~ (2015)
- Ganzevles, S., "Using tri-axial accelerometry in daily elite swim training practice", Sensors, 17(5), pp.990~ (2017)
- "Fenix 3HR" (2017)[URL]
- Holmer, I., "Oxygen uptake during swimming in man", Journal of Applied Physiology, 33(4), pp.502~509 (1972)
- "Xiaomi and Apple Tie for the Top Position as the Wearables Market Swells 17.9% During the First Quarter, According to IDC" (2017)[URL]
- Lee, J. M., "Validity of consumer-based physical activity monitors", Med Sci Sports Exerc, 46, pp.1840~1848 (2014)
- Keskinen, K. L., "Respiratory snorkel and valve system for breath‐by‐breath gas analysis in swimming", Scandinavian Journal of Medicine & Science in Sports, 13(5), pp.322~329 (2003)
- McLaughlin, J., "Validation of the Cosmed K4b2 portable metabolic system", International Journal of Sports and Medicine, 22, pp.280~284 (2001)
- Montpetit, R., "Energy expenditure during front crawl swimming : A comparison between males and females. Swimming Science V. Human Kinetics", Champaign, 101, pp.229~236 (1988)
- Mooney R, "Application of video-based methods for competitive swimming analysis: a systematic review", Sports and Exercise Medicine, 1, pp.133~150 (2015)
- Mooney, R., "Evaluation of the Finis Swimsense® and the Garmin Swim™activity monitors for swimming performance and stroke kinematics analysis", PloS One, 12(2), pp.e0170902~ (2017)
- Nordsborg, N. B., "Estimating energy expenditure during front crawl swimming using accelerometers", Procedia Engineering, 72, pp.132~137 (2014)
- Pendergast, D. R., "Quantitative analysis of the front crawl in men and women", Journal of Applied Physiology, 43(3), pp.475~479 (1977)
- Stahl, S. E., "How accurate are the wrist-based heart rate monitors during walking and running activities? Are they accurate enough?", BMJ Open Sport & Exercise Medicine, 2(1), pp.e000106~ (2016)
- Wallen, M. P., "Accuracy of heart rate watches: implications for weight management", PLoS One, 11(5), pp.e0154420~ (2016)
- Zamparo, P., "Energy cost of swimming of elite long-distance swimmers", European Journal of Applied Physiology, 94(5–6), pp.697~704 (2005)
