Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Hemolytic anemia is recognized as a rare complication of mitral valve replacement or repair. We report on a 44-year-old man with shortness of breath and hemolytic anemia, 23 years after mitral valve replacement (Hall-Kaster), and a 63-year-old woman diagnosed of hemolytic anemia, 4 years after mitral and tricuspid annuloplasty (Tailor ring, An-core ring). Routine 2-dimensional transthoracic echocardiography revealed paravalvular leakage around the prosthesis. Subsequent real-time 3-dimensional (3D)transesophageal echocardiography helped the perceptional appreciation of the leakage and the measuring of the regurgitant orifice area using the anatomically correct plane. Surgical findings of each case fit those of 3D volumetric images.
Abstract
Hemolytic anemia is recognized as a rare complication of mitral valve replacement or repair. We report on a 44-year-old man with shortness of breath and hemolytic anemia, 23 years after mitral valve replacement (Hall-Kaster), and a 63-year-old woman diagnosed of hemolytic anemia, 4 years after mitral and tricuspid annuloplasty (Tailor ring, An-core ring). Routine 2-dimensional transthoracic echocardiography revealed paravalvular leakage around the prosthesis. Subsequent real-time 3-dimensional (3D)transesophageal echocardiography helped the perceptional appreciation of the leakage and the measuring of the regurgitant orifice area using the anatomically correct plane. Surgical findings of each case fit those of 3D volumetric images.
참고문헌 (10)
- Edmunds LH Jr, "Guidelines for reporting morbidity and mortality after cardiac valvular operations. Ad Hoc Liaison Committee for Standardizing Definitions of Prosthetic Heart Valve Morbidity of The American Association for Thoracic Surgery and The Society of Thoracic Surgeons", J Thorac Cardiovasc Surg, 112, pp.708~711 (1996)
- Maraj R, "Evaluation of hemolysis in patients with prosthetic heart valves", Clin Cardiol, 21, pp.387~392 (1988)
- Garcia MJ, "Mechanisms of hemolysis with mitral prosthetic regurgitation. Study using transesophageal echocardiography and fluid dynamic simulation", J Am Coll Cardiol, 27, pp.399~406 (1996)
- Iguro Y, "Clinical experience of 473 patients with the omnicarbon prosthetic heart valve", J Heart Valve Dis, 8, pp.674~679 (1999)
- Skoularigis J, "Frequency and severity of intravascular hemolysis after left-sided cardiac valve replacement with Medtronic Hall and St. Jude Medical prostheses, and influence of prosthetic type, position, size and number", Am J Cardiol, 71, pp.587~591 (1993)
- Mecozzi G, "Intravascular hemolysis in patients with new-generation prosthetic heart valves: a prospective study", J Thorac Cardiovasc Surg, 123, pp.550~556 (2002)
- Demirsoy E, "Hemolysis after mitral valve repair: a report of five cases and literature review", J Heart Valve Dis, 17, pp.24~30 (2008)
- Yang HS, "American Society of Echocardiography. Practical guide for three-dimensional transthoracic echocardiography using a fully sampled matrix array transducer", J Am Soc Echocardiogr, 21, pp.979~989 (2008)
- Sugeng L, "Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves", J Am Soc Echocardiogr, 21, pp.1347~1354 (2008)