본문 바로가기
KERD
논문KCI 등재

Intermittent, Non Cyclic Severe Mechanical Aortic Valve Regurgitation

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류내과학

초록

Mechanical aortic prosthesis dysfunction can result from thrombosis or pannus formation. We describe an unusual case of intermittent, non cyclic mechanical aortic prosthesis dysfunction due to pannus formation with thrombus in the absence of systolic restriction of disk excursion, that presented with intermittent severe aortic regurgitation.

Abstract

Mechanical aortic prosthesis dysfunction can result from thrombosis or pannus formation. We describe an unusual case of intermittent, non cyclic mechanical aortic prosthesis dysfunction due to pannus formation with thrombus in the absence of systolic restriction of disk excursion, that presented with intermittent severe aortic regurgitation.

참고문헌 (9)

  1. Bouma BJ, "Dysfunction of an aortic prosthetic valve", Heart, 91, pp.1120~ (2005)
  2. Robles P, "Intermittent aortic regurgitation in a case of mechanical prosthesis dysfunction", Int J Cardiol, 102, pp.525~527 (2005)
  3. Galli CA, "Cyclic intermittent aortic regurgitation of a mechanical bileaflet aortic valve prosthesis: diagnosis and clinical implications", J Am Soc Echocardiogr, 20(1315), pp.e5~e8 (2007)
  4. Karagiannis SE, "Intermittent acute aortic valve regurgitation: a case report of a prosthetic valve dysfunction", Eur J Echocardiogr, 9, pp.291~293 (2008)
  5. Cianciulli TF, "Intermittent acute aortic regurgitation of a mechanical bileaflet aortic valve prosthesis: diagnosis and clinical implications", Eur J Echocardiogr, 10, pp.446~449 (2009)
  6. Giroux SK, "Intermittent, noncyclic dysfunction of a mechanical aortic prosthesis by pannus formation", J Am Soc Echocardiogr, 23(107), pp.e1~e3 (2010)
  7. Teshima H, "Obstruction of St Jude Medical valves in the aortic position: histology and immunohistochemistry of pannus", J Thorac Cardiovasc Surg, 126, pp.401~407 (2003)
  8. Barbetseas J, "Differentiating thrombus from pannus formation in obstructed mechanical prosthetic valves: an evaluation of clinical, transthoracic and transesophageal echocardiographic parameters", J Am Coll Cardiol, 32, pp.1410~1417 (1998)
  9. Rizzoli G, "Reoperations for acute prosthetic thrombosis and pannus: an assessment of rates, relationship and risk", Eur J Cardiothorac Surg, 16, pp.74~80 (1999)

관련 논문AI추천