Comparison of Left Ventricular Volumes Measured by 3DE, SPECT and CMR
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
BACKGROUND: Information regarding left ventricular (LV) volume and left ventricular ejection fraction (LVEF) has major diagnostic and prognostic value when assessing patients after ST-elevation myocardial infarction (STEMI). We aimed to investigate the agreement between measurement of LV volumes and LVEF by three-dimensional echocardiography (3DE), single-photon emission computed tomography (SPECT) and cardiac magnetic resonance (CMR) imaging in patients in a stable phase after STEMI. METHODS: Fifteen patients underwent examinations by 3DE, SPECT and CMR three months after STEMI. RESULTS: There was a significant bias in end-diastolic volume (EDV) measured by 3DE (–64 mL, p < 0.001) and SPECT (–55 mL, p < 0.001) compared with that measured by CMR. This was also the case for end-systolic volume (ESV) measured by 3DE (–36 mL, p < 0.001) and SPECT (–28 mL, p < 0.001). No significant differences were found between 3DE and SPECT for EDV or ESV. However, LVEF did not differ between the three methods. The agreement between all three methods was moderate (intra-class correlation coefficient [ICC] = 0.44) for LV volume and good for LVEF (ICC = 0.72). CONCLUSIONS: LV volumes assessed by 3DE did not differ from SPECT, and despite larger LV volumes by CMR, measurements of LVEF showed good agreement between all three methods.
Abstract
BACKGROUND: Information regarding left ventricular (LV) volume and left ventricular ejection fraction (LVEF) has major diagnostic and prognostic value when assessing patients after ST-elevation myocardial infarction (STEMI). We aimed to investigate the agreement between measurement of LV volumes and LVEF by three-dimensional echocardiography (3DE), single-photon emission computed tomography (SPECT) and cardiac magnetic resonance (CMR) imaging in patients in a stable phase after STEMI. METHODS: Fifteen patients underwent examinations by 3DE, SPECT and CMR three months after STEMI. RESULTS: There was a significant bias in end-diastolic volume (EDV) measured by 3DE (–64 mL, p < 0.001) and SPECT (–55 mL, p < 0.001) compared with that measured by CMR. This was also the case for end-systolic volume (ESV) measured by 3DE (–36 mL, p < 0.001) and SPECT (–28 mL, p < 0.001). No significant differences were found between 3DE and SPECT for EDV or ESV. However, LVEF did not differ between the three methods. The agreement between all three methods was moderate (intra-class correlation coefficient [ICC] = 0.44) for LV volume and good for LVEF (ICC = 0.72). CONCLUSIONS: LV volumes assessed by 3DE did not differ from SPECT, and despite larger LV volumes by CMR, measurements of LVEF showed good agreement between all three methods.
참고문헌 (34)
- Eriksson SV, "Long-term prognostic significance of M mode echocardiography in young men after myocardial infarction", Br Heart J, 74, pp.124~130 (1995)
- Galderisi M, "Echocardiographic determinants of clinical outcome in subjects with coronary artery disease(the Framingham Heart Study)", Am J Cardiol, 70, pp.971~976 (1992)
- Funaro S, "Incidence, determinants, and prognostic value of reverse left ventricular remodelling after primary percutaneous coronary intervention : results of the Acute Myocardial Infarction Contrast Imaging(AMICI)multicenter study", Eur Heart J, 30, pp.566~575 (2009)
- Sheehan FH, "Early recovery of left ventricular function after thrombolytic therapy for acute myocardial infarction : an important determinant of survival", J Am Coll Cardiol, 12, pp.289~300 (1988)
- Carstensen S, "Effects of early enalapril treatment on global and regional wall motion in acute myocardial infarction. CONSENSUS II Multi Echo Study Group", Am Heart J, 129, pp.1101~1108 (1995)
- Ibanez B, "2017 ESC Guidelines for the management of acute myocardial infarction in patients presenting with ST-segment elevation : The Task Force for the management of acute myocardial infarction in patients presenting with ST-segment elevation of the European Society of Cardiology(ESC)", Eur Heart J, 39, pp.119~177 (2018)
- Pfeffer MA, "Effect of captopril on mortality and morbidity in patients with left ventricular dysfunction after myocardial infarction. Results of the survival and ventricular enlargement trial. The SAVE Investigators", N Engl J Med, 327, pp.669~677 (1992)
- Alfakih K, "Assessment of ventricular function and mass by cardiac magnetic resonance imaging", Eur Radiol, 14, pp.1813~1822 (2004)
- Ioannidis JP, "Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction : a meta-analysis", J Am Coll Cardiol, 39, pp.2059~2068 (2002)
- Mesquita CT, "Ventricular function following coronary artery bypass grafting : comparison between gated SPECT and cardiac magnetic resonance imaging", Arq Bras Cardiol, 92, pp.327~333 (2009)
- Paul AK, "Gated myocardial perfusion SPECT : basic principles, technical aspects, and clinical applications", J Nucl Med Technol, 32, pp.179~187 (2004)
- Pennell DJ, "Ventricular volume and mass by CMR", J Cardiovasc Magn Reson, 4, pp.507~513 (2002)
- Jenkins C, "Comparison of two-and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction", Am J Cardiol, 99, pp.300~306 (2007)
- Kawai J, "Rapid freehand scanning three-dimensional echocardiography : accurate measurement of left ventricular volumes and ejection fraction compared with quantitative gated scintigraphy", J Am Soc Echocardiogr, 16, pp.110~115 (2003)
- Lipiec P, "Gated 99mTc-MIBI single-photon emission computed tomography for the evaluation of left ventricular ejection fraction : comparison with three-dimensional echocardiography", Ann Nucl Med, 22, pp.723~726 (2008)
- Mannaerts HF, "Quantification of left ventricular volumes and ejection fraction using freehand transthoracic three-dimensional echocardiography : comparison with magnetic resonance imaging", J Am Soc Echocardiogr, 16, pp.101~109 (2003)
- Persson E, "Evaluation of left ventricular volumes and ejection fraction by automated gated myocardial SPECT versus cardiovascular magnetic resonance", Clin Physiol Funct Imaging, 25, pp.135~141 (2005)
- Tighe DA, "Influence of image quality on the accuracy of real time three-dimensional echocardiography to measure left ventricular volumes in unselected patients : a comparison with gated-SPECT imaging", Echocardiography, 24, pp.1073~1080 (2007)
- Chan J, "What is the optimal clinical technique for measurement of left ventricular volume after myocardial infarction? A comparative study of 3-dimensional echocardiography, single photon emission computed tomography, and cardiac magnetic resonance imaging", J Am Soc Echocardiogr, 19, pp.192~201 (2006)
- Sörensson P, "Effect of postconditioning on infarct size in patients with ST elevation myocardial infarction", Heart, 96, pp.1710~1715 (2010)
- Heiberg E, "Design and validation of Segment--freely available software for cardiovascular image analysis", BMC Med Imaging, 10, pp.1~ (2010)
- Landis JR, "The measurement of observer agreement for categorical data", Biometrics, 33, pp.159~174 (1977)
- Chan YH, "Biostatistics 104 : correlational analysis", Singapore Med J, 44, pp.614~619 (2003)
- Mor-Avi V, "Real-time 3-dimensional echocardiographic quantification of left ventricular volumes : multicenter study for validation with magnetic resonance imaging and investigation of sources of error", JACC Cardiovasc Imaging, 1, pp.413~423 (2008)
- Mistry N, "Assessment of left ventricular function with magnetic resonance imaging vs. echocardiography, contrast echocardiography, and single-photon emission computed tomography in patients with recent ST-elevation myocardial infarction", Eur J Echocardiogr, 11, pp.793~800 (2010)
- Bavelaar-Croon CD, "Left ventricular function : correlation of quantitative gated SPECT and MR imaging over a wide range of values", Radiology, 217, pp.572~575 (2000)
- Thorley PJ, "Comparison of 99mTc tetrofosmin gated SPECT measurements of left ventricular volumes and ejection fraction with MRI over a wide range of values", Nucl Med Commun, 24, pp.763~769 (2003)
- Binder T, "Three-dimensional echocardiography : principles and promises", J Clin Basic Cardiol, 5, pp.149~152 (2002)
- Johri AM, "Three dimensional echocardiography : approaches and clinical utility", Heart, 96, pp.390~397 (2010)
- Mor-Avi V, "The use of real-time three-dimensional echocardiography for the quantification of left ventricular volumes and function", Curr Opin Cardiol, 24, pp.402~409 (2009)
- Thavendiranathan P, "Reproducibility of echocardiographic techniques for sequential assessment of left ventricular ejection fraction and volumes : application to patients undergoing cancer chemotherapy", J Am Coll Cardiol, 61, pp.77~84 (2013)
- Jenkins C, "Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography", J Am Coll Cardiol, 44, pp.878~886 (2004)
- Bellenger NG, "Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance", J Cardiovasc Magn Reson, 2, pp.271~278 (2000)
- Soneson H, "An improved method for automatic segmentation of the left ventricle in myocardial perfusion SPECT", J Nucl Med, 50, pp.205~213 (2009)
