Diagnostic Value of Lesion-specific Measurement of Myocardial Blood Flow Using Hybrid PET/CT
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
BACKGROUND: We evaluated whether lesion-specific measurement of myocardial blood flow (MBF) and flow reserve (MFR) by hybrid imaging of myocardial perfusion positron emission tomography (PET) and coronary computed tomography (CT) can provide additional diagnostic value. METHODS: Forty-three patients with stable angina underwent N-13 ammonia PET and coronary CT before invasive coronary angiography (CAG). The lesion-specific MBF was calculated from the average MBF of the myocardial segments downstream of a coronary stenosis using hybrid PET/CT images. The hyperemic MBF, resting MBF, and MFR were measured for the left anterior descending artery (LAD) using conventional and lesion-specific methods. The diagnostic accuracy was compared between the two methods for significant LAD stenoses (≥ 70% reference diameter on CAG). RESULTS: There were 19 significant LAD stenoses. The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy were 71%, 68%, 74%, 65%, and 70% for conventional hyperemic MBF (optimal cutoff = 2.15 mL/min/g), 79%, 63%, 74%, 65%, and 70% for conventional MFR (optimal cutoff = 1.82), 83%, 74%, 80%, 78%, and 80% for lesion-specific hyperemic MBF (optimal cutoff = 1.75 mL/min/g), and 79%, 79%, 83%, 75%, and 79% for lesion-specific MFR (optimal cutoff = 1.86), respectively. The lesion-specific measurement was more accurate and had a better linear correlation with anatomical stenosis severity for both hyperemic MBF and MFR. CONCLUSIONS: Lesion-specific measurement using hybrid PET/CT imaging showed significant improvement in the diagnostic accuracy of PET-measured hyperemic MBF and MFR.
Abstract
BACKGROUND: We evaluated whether lesion-specific measurement of myocardial blood flow (MBF) and flow reserve (MFR) by hybrid imaging of myocardial perfusion positron emission tomography (PET) and coronary computed tomography (CT) can provide additional diagnostic value. METHODS: Forty-three patients with stable angina underwent N-13 ammonia PET and coronary CT before invasive coronary angiography (CAG). The lesion-specific MBF was calculated from the average MBF of the myocardial segments downstream of a coronary stenosis using hybrid PET/CT images. The hyperemic MBF, resting MBF, and MFR were measured for the left anterior descending artery (LAD) using conventional and lesion-specific methods. The diagnostic accuracy was compared between the two methods for significant LAD stenoses (≥ 70% reference diameter on CAG). RESULTS: There were 19 significant LAD stenoses. The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy were 71%, 68%, 74%, 65%, and 70% for conventional hyperemic MBF (optimal cutoff = 2.15 mL/min/g), 79%, 63%, 74%, 65%, and 70% for conventional MFR (optimal cutoff = 1.82), 83%, 74%, 80%, 78%, and 80% for lesion-specific hyperemic MBF (optimal cutoff = 1.75 mL/min/g), and 79%, 79%, 83%, 75%, and 79% for lesion-specific MFR (optimal cutoff = 1.86), respectively. The lesion-specific measurement was more accurate and had a better linear correlation with anatomical stenosis severity for both hyperemic MBF and MFR. CONCLUSIONS: Lesion-specific measurement using hybrid PET/CT imaging showed significant improvement in the diagnostic accuracy of PET-measured hyperemic MBF and MFR.
참고문헌 (30)
- Fiechter M, "Diagnostic value of 13N-ammonia myocardial perfusion PET : added value of myocardial flow reserve", J Nucl Med, 53, pp.1230~1234 (2012)
- Lee JM, "Integrated myocardial perfusion imaging diagnostics improve detection of functionally significant coronary artery stenosis by 13N-ammonia positron emission tomography", Circ Cardiovasc Imaging, 9, pp.e004768~ (2016)
- Ziadi MC, "Does quantification of myocardial flow reserve using rubidium-82 positron emission tomography facilitate detection of multivessel coronary artery disease", J Nucl Cardiol, 19, pp.670~680 (2012)
- Herzog BA, "Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography added value of coronary flow reserve", J Am Coll Cardiol, 54, pp.150~156 (2009)
- Taqueti VR, "Global coronary flow reserve is associated with adverse cardiovascular events independently of luminal angiographic severity and modifies the effect of early revascularization", Circulation, 131, pp.19~27 (2015)
- Gupta A, "Integrated noninvasive physiological assessment of coronary circulatory function and impact on cardiovascular mortality in patients with stable coronary artery disease", Circulation, 136, pp.2325~2336 (2017)
- Cho SG, "Flow-based functional assessment of coronary artery disease by myocardial perfusion positron emission tomography in the era of fractional flow reserve", Ann Nucl Cardiol, 2, pp.99~105 (2016)
- Thomassen A, "Quantitative myocardial perfusion by O-15-water PET: individualized vs. standardized vascular territories", Eur Heart J Cardiovasc Imaging, 16, pp.970~976 (2015)
- Dey D, "Relationship between quantitative adverse plaque features from coronary computed tomography angiography and downstream impaired myocardial flow reserve by 13N-ammonia positron emission tomography : a pilot study", Circ Cardiovasc Imaging, 8, pp.e003255~ (2015)
- Cho SG, "Coronary flow reserve and relative flow reserve measured by N-13 ammonia PET for characterization of coronary artery disease", Ann Nucl Med, 31, pp.144~152 (2017)
- Bom MJ, "Impact of individualized segmentation on diagnostic performance of quantitative positron emission tomography for haemodynamically significant coronary artery disease", Eur Heart J Cardiovasc Imaging, 20, pp.525~532 (2019)
- Dilsizian V, "ASNC imaging guidelines", SNMMI procedure standard for positron emission tomography(PET)nuclear cardiology procedures, 2016, pp.23, 1187~1226
- Cerqueira MD, "Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association", Int J Cardiovasc Imaging, 18, pp.539~542 (2002)
- Nørgaard BL, "Coronary CT angiographic and flow reserve-guided management of patients with stable ischemic heart disease", J Am Coll Cardiol, 72, pp.2123~2134 (2018)
- George RT, "Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320-MDCT : the CT angiography and perfusion methods of the CORE320 multicenter multinational diagnostic study", AJR Am J Roentgenol, 197, pp.829~837 (2011)
- ICRP, "ICRP publication 80 : Radiation dose to patients from radiopharmaceuticals(addendum 2 to ICRP publication 53)", Ann ICRP, 28, pp.1~126 (1998)
- Trattner S, "Cardiac-specific conversion factors to estimate radiation effective dose from dose-length product in computed tomography", JACC Cardiovasc Imaging, 11, pp.64~74 (2018)
- Christner JA, "Estimating effective dose for CT using dose-length product compared with using organ doses : consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning", AJR Am J Roentgenol, 194, pp.881~889 (2010)
- Maddox TM, "Nonobstructive coronary artery disease and risk of myocardial infarction", JAMA, 312, pp.1754~1763 (2014)
- DeLong ER, "Comparing the areas under two or more correlated receiver operating characteristic curves : a nonparametric approach", Biometrics, 44, pp.837~845 (1988)
- Donato P, "Correspondence between left ventricular 17 myocardial segments and coronary anatomy obtained by multi-detector computed tomography : an ex vivo contribution", Surg Radiol Anat, 34, pp.805~810 (2012)
- 김현식, "Indirect Radionuclide Coronary Angiography to Evaluate Gradients of Myocardial Blood Flow and Flow Reserve Through Coronary Stenosis Using N-13 Ammonia PET", CT, 2013, pp.49(2), 69~74[DOI]
- Marina Piccinelli, "Vessel-specific quantification of absolute myocardial blood flow, myocardial flow reserve and relative flow reserve by means of fused dynamic 13NH3 PET and CCTA: Ranges in a low-risk population and abnormality criteria", Journal of Nuclear Cardiology, 27(5), pp.1756~1769 (2020), Springer Science and Business Media LLC[DOI]
- Kim HY, "Physiological severity of coronary artery stenosis depends on the amount of myocardial mass subtended by the coronary artery", JACC Cardiovasc Interv, 9, pp.1548~1560 (2016)
- Kim HY, "Identification of coronary artery side branch supplying myocardial mass that may benefit from revascularization", JACC Cardiovasc Interv, 10, pp.571~581 (2017)
- Yang DH, "Incremental value of subtended myocardial mass for identifying FFR-verified ischemia using quantitative CT angiography : comparison with quantitative coronary angiography and CT-FFR", JACC Cardiovasc Imaging, 12, pp.707~717 (2019)
- Gaur S, "Coronary plaque quantification and fractional flow reserve by coronary computed tomography angiography identify ischaemia-causing lesions", Eur Heart J, 37, pp.1220~1227 (2016)
- van de Hoef TP, "Fundamentals in clinical coronary physiology : why coronary flow is more important than coronary pressure", Eur Heart J, 36, pp.3312~3319 (2015)
- Kajander S, "Low radiation dose imaging of myocardial perfusion and coronary angiography with a hybrid PET", CT scanner, 2009, pp.29, 81~88
- Einstein AJ, "Effects of radiation exposure from cardiac imaging: how good are the data?", J Am Coll Cardiol, 59, pp.553~565 (2012)