본문 바로가기
KERD
논문KCI 등재후보

CartoMerge using SoundStar Catheter and Time Force Integral-Based Ablation for Atrial Fibrillation

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류의학일반

초록

Catheter ablation for atrial fibrillation is based on pulmonary vein (PV) isolation, but this procedure is thought to be demanding. The visualization of 3-dimensional information that is provided by CartoMerge® (BioSense Webster Inc., Diamond Bar, CA, USA) makes the ablation procedure easier. The SoundStar® catheter (BioSense Webster Inc., Diamond Bar, CA, USA)became available in Korea in September 2016. CartoMerge® using a SoundStar® catheter, which we termed as SoundMerge, is a simple way to obtain good CartoMerge® results. In addition, information on catheter stability and ablation intensity at each site are provided by a new ablation annotation system (CARTO® 3 System, VisiTag™ Module [BioSense Webster Inc., Diamond Bar, CA, USA]), which would be helpful for accomplishing durable PV isolation. In this article, we introduce the methodology of SoundMerge and the setting of the VisiTag™ module that we are performing currently. Effective practical use of these new technologies would improve the quality of ablation procedures.

Abstract

Catheter ablation for atrial fibrillation is based on pulmonary vein (PV) isolation, but this procedure is thought to be demanding. The visualization of 3-dimensional information that is provided by CartoMerge® (BioSense Webster Inc., Diamond Bar, CA, USA) makes the ablation procedure easier. The SoundStar® catheter (BioSense Webster Inc., Diamond Bar, CA, USA)became available in Korea in September 2016. CartoMerge® using a SoundStar® catheter, which we termed as SoundMerge, is a simple way to obtain good CartoMerge® results. In addition, information on catheter stability and ablation intensity at each site are provided by a new ablation annotation system (CARTO® 3 System, VisiTag™ Module [BioSense Webster Inc., Diamond Bar, CA, USA]), which would be helpful for accomplishing durable PV isolation. In this article, we introduce the methodology of SoundMerge and the setting of the VisiTag™ module that we are performing currently. Effective practical use of these new technologies would improve the quality of ablation procedures.

참고문헌 (3)

  1. Ullah W, "Randomized trial comparing pulmonary vein isolation using the smarttouch catheter with or without real-time contact force data", Heart Rhythm, 13, pp.1761~1767 (2016)
  2. Patel AR, "Cardiac cycle–dependent left atrial dynamics : Implications for catheter ablation of atrial fibrillation", Heart Rhythm, 5, pp.787~793 (2008)
  3. Ector J, "Changes in left atrial anatomy due to respiration : impact on three-dimensional image integration during atrial fibrillation ablation", J Cardiovasc Electrophysiol, 19, pp.828~834 (2008)

관련 논문AI추천

Comparative Efficacy and Procedural Durability of Radiofrequency Ablation for Atrial Fibrillation: A Systematic Review and a Meta-Analysis박소희, 박은철, 지선하, 최현숙한국보건의료기술평가학회 · 보건의료기술평가2015 · 제3권 제1호2018 심방세동 카테터 절제술 대한민국 진료지침: Part II김준, 김기훈, 김주연, 노승영, 박형섭, 박희남, 심재민, 오용석, 유희태, 윤남식, 이정명, 정동섭, 조영진대한부정맥학회 · International Journal of Arrhythmia2018 · 제19권 제3호Invasive strategies for rhythm control of atrial fibrillation: a narrative review김홍주, Chan-Hee Lee영남대학교 의과대학 · Journal of Yeungnam Medical Science2024 · 제41권 제4호2018 심방세동 카테테 절제술 대한민국 진료지침: Part III김준, 김기훈, 김주연, 노승영, 박형섭, 박희남, 심재민, 오세일, 유희태, 윤남식, 이정명, 정동섭, 조영진대한부정맥학회 · International Journal of Arrhythmia2018 · 제19권 제3호Endurance Ablation Facilitates Long-lasting Circumferential Pulmonary Vein Isolation and Better Clinical Outcomes in Patients with Paroxysmal Atrial Fibrillation김종윤, 김태훈, 박준범, 박희남, 엄재선, 유희태, 이문형, 정보영대한부정맥학회 · International Journal of Arrhythmia2017 · 제18권 제3호Detailed Electrode Catheter Positioning is Important for the Ablation of Outflow Tract Origin Ventricular Arrhythmias김성환, 김유리, 김정호, 김주연, 김지훈, 김태석, 노태호, 송인걸, 오용석, 이만영, 장성원대한부정맥학회 · International Journal of Arrhythmia2017 · 제18권 제4호

이 간행물의 다른 논문 (9건)