2018 심방세동 카테테 절제술 대한민국 진료지침: Part III
2018 Korean Guidelines for Catheter Ablation of Atrial Fibrillation: Part III
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Catheter ablation of atrial fibrillation (AF) is one of the most complex interventional electrophysiological procedures. The success of AF ablation is based in large part on freedom from AF recurrence based on electrocardiography (ECG) monitoring. Arrhythmia monitoring can be performed with the use of noncontinuous or continuous ECG monitoring tools. AF ablation is an invasive procedure that entails risks, most of which are present during the acute procedural period. However, complications can also occur in the weeks or months following ablation. Recognizing common symptoms after AF ablation and distinguishing those that require urgent evaluation and referral to an electrophysiologist is an important part of follow-up after AF ablation. This section reviews the complications associated with catheter ablation procedures performed to treat AF. The types and incidence of complications are presented, their mechanisms are explored, and the optimal approach to prevention and treatment is discussed. Finally, surgical and hybrid AF ablation technology and the indications for concomitant open or closed surgical ablation of AF, stand-alone and hybrid surgical ablation of AF are covered in this section.
Abstract
Catheter ablation of atrial fibrillation (AF) is one of the most complex interventional electrophysiological procedures. The success of AF ablation is based in large part on freedom from AF recurrence based on electrocardiography (ECG) monitoring. Arrhythmia monitoring can be performed with the use of noncontinuous or continuous ECG monitoring tools. AF ablation is an invasive procedure that entails risks, most of which are present during the acute procedural period. However, complications can also occur in the weeks or months following ablation. Recognizing common symptoms after AF ablation and distinguishing those that require urgent evaluation and referral to an electrophysiologist is an important part of follow-up after AF ablation. This section reviews the complications associated with catheter ablation procedures performed to treat AF. The types and incidence of complications are presented, their mechanisms are explored, and the optimal approach to prevention and treatment is discussed. Finally, surgical and hybrid AF ablation technology and the indications for concomitant open or closed surgical ablation of AF, stand-alone and hybrid surgical ablation of AF are covered in this section.
참고문헌 (362)
- Cappato R, "Up-dated worldwide survey on the methods, efficacy and safety of catheter ablation for human atrial fibrillation", Circ Arrhythm Electrophysiol, 3, pp.32~38 (2010)
- Deshmukh A, "In-hospital complications associated with catheter ablation of atrial fibrillation in the United States between 2000 and 2010 : analysis of 93 801 procedures", Circulation, 128, pp.2104~2112 (2013)
- Gupta A, "Complications of catheter ablation of atrial fibrillation : a systematic review", Circ Arrhythm Electrophysiol, 6, pp.1082~1088 (2013)
- Dukkipati SR, "Pulmonary Vein Isolation Using the Visually Guided Laser Balloon A Prospective, Multicenter, and Randomized Comparison to Standard Radiofrequency Ablation", J Am Coll Cardiol, 66, pp.1350~1360 (2015)
- Takahashi Y, "Acute occlusion of the left circumflex coronary artery during mitral isthmus linear ablation", J Cardiovasc Electrophysiol, 16, pp.1104~1107 (2005)
- Chilukuri K, "Association of transseptal punctures with isolated migraine aura in patients undergoing catheter ablation of cardiac arrhythmias", J Cardiovasc Electrophysiol, 20, pp.1227~1230 (2009)
- Noheria A, "Migraine headaches following catheter ablation for atrial fibrillation", J Interv Card Electrophysiol, 30, pp.227~232 (2011)
- Barbhaiya CR, "Global survey of esophageal and gastric injury in atrial fibrillation ablation : incidence, time to presentation, and outcomes", J Am Coll Cardiol, 65, pp.1377~1378 (2015)
- Lakkireddy D, "Effect of atrial fibrillation ablation on gastric motility : the atrial fibrillation gut study", Circ Arrhythm Electrophysiol, 8, pp.531~536 (2015)
- Lee DS, "Severe Gastroparesis following Radiofrequency Catheter Ablation for Atrial Fibrillation : Suggestion for Diagnosis, Treatment, and Device for Gastroparesis after RFCA", Case Rep Gastrointest Med, 2014, pp.923637~ (2014)
- Park YM, "Torsades de Pointes associated with QT prolongation after catheter ablation of paroxysmal atrial fibrillation", Indian Pacing Electrophysiol J, 17, pp.146~149 (2017)
- Pappone C, "Atrio-esophageal fistula as a complication of percutaneous transcatheter ablation of atrial fibrillation", Circulation, 109, pp.2724~2726 (2004)
- Mohanty S, "Catheter ablation of asymptomatic longstanding persistent atrial fibrillation : impact on quality of life, exercise performance, arrhythmia perception, and arrhythmia-free survival", J Cardiovasc Electrophysiol, 25, pp.1057~1064 (2014)
- Mohanty S, "Outcomes of atrioesophageal fistula following catheter ablation of atrial fibrillation treated with surgical repair versus esophageal stenting", J Cardiovasc Electrophysiol, 25, pp.579~584 (2014)
- Mohanty S, "Impact of Alcohol Intake on Thromboembolic Events Following Catheter Ablation for Atrial Fibrillation", J Am Coll Cardiol, 63, pp.A403~A403 (2014)
- 서정민, "Pericardial-esophageal Fistula Complicating Atrial Fibrillation Ablation Successfully Resolved after Pericardial Drainage with Conservative Management", Korean Circulation Journal, 47(6), pp.970~977 (2017), 대한심장학회[DOI]
- Fender EA, "Pulmonary vein stenosis after atrial fibrillation ablation", Eurointervention, 12, pp.X31~X34 (2016)
- Holmes DR Jr., "Pulmonary vein stenosis complicating ablation for atrial fibrillation : clinical spectrum and interventional considerations", JACC Cardiovasc Interv, 2, pp.267~276 (2009)
- Hee Kwon C, "Severe Pulmonary Vein Stenosis and Extensive Left Atrial Stricture After Radiofrequency Catheter Ablation of Atrial Fibrillation", J Cardiovasc Electrophysiol, 26, pp.1151~1152 (2015)
- 박영아, "Controlled Atrial Fibrillation after Pulmonary Vein Stenting", Korean Circulation Journal, 47(4), pp.528~531 (2017), 대한심장학회
- Sauer WH, "Atrioventricular nodal reentrant tachycardia in patients referred for atrial fibrillation ablation-Response to ablation that incorporates slow-pathway modification", Circulation, 114, pp.191~195 (2006)
- Kirchhof P, "Comprehensive risk reduction in patients with atrial fibrillation : emerging diagnostic and therapeutic options--a report from the 3rd Atrial Fibrillation Competence NETwork", European Heart Rhythm Association consensus conference, 2012, pp.14, 8~27
- Oral H, "Risk of thromboembolic events after percutaneous left atrial radiofrequency ablation of atrial fibrillation", Circulation, 114, pp.759~765 (2006)
- Oral H, "A tailored approach to catheter ablation of paroxysmal atrial fibrillation", Circulation, 113, pp.1824~1831 (2006)
- Gentlesk PJ, "Reversal of left ventricular dysfunction following ablation of atrial fibrillation", J Cardiovasc Electrophysiol, 18, pp.9~14 (2007)
- Vasamreddy CR, "Predictors of recurrence following catheter ablation of atrial fibrillation using an irrigated-tip ablation catheter", J Cardiovasc Electrophysiol, 15, pp.692~697 (2004)
- Bertaglia E, "Predictive value of early atrial tachyarrhythmias recurrence after circumferential anatomical pulmonary vein ablation", Pacing Clin Electrophysiol, 28, pp.366~371 (2005)
- Willems S, "Redefining the Blanking Period After Catheter Ablation for Paroxysmal Atrial Fibrillation: Insights From the ADVICE (Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination)", Trial. Circulation, 9, pp.e003909~ (2016)
- Kaitani K, "Efficacy of antiarrhythmic drugs short-term use after catheter ablation for atrial fibrillation(EAST-AF)trial", Eur Heart J, 37, pp.610~618 (2016)
- Gaztanaga L, "Time to recurrence of atrial fibrillation influences outcome following catheter ablation", Heart Rhythm, 10, pp.2~9 (2013)
- Das M, "Recurrence of atrial tachyarrhythmia during the second month of the blanking period is associated with more extensive pulmonary vein reconnection at repeat electrophysiology study", Circ Arrhythm Electrophysiol, 8, pp.846~852 (2015)
- Arya A, "Long-term results and the predictors of outcome of catheter ablation of atrial fibrillation using steerable sheath catheter navigation after single procedure in 674 patients", Europace, 12, pp.173~180 (2010)
- Vasamreddy CR, "Symptomatic and asymptomatic atrial fibrillation in patients undergoing radiofrequency catheter ablation", J Cardiovasc Electrophysiol, 17, pp.134~139 (2006)
- Klemm HU, "Correlation of symptoms to ECG diagnosis following atrial fibrillation ablation", J Cardiovasc Electrophysiol, 17, pp.146~150 (2006)
- Wokhlu A, "Long-term quality of life after ablation of atrial fibrillation the impact of recurrence, symptom relief, and placebo effect", J Am Coll Cardiol, 55, pp.2308~2316 (2010)
- Senatore G, "Role of transtelephonic electrocardiographic monitoring in detecting short-term arrhythmia recurrences after radiofrequency ablation in patients with atrial fibrillation", J Am Coll Cardiol, 45, pp.873~876 (2005)
- Pokushalov E, "Ablation of paroxysmal and persistent atrial fibrillation : 1-year follow-up through continuous subcutaneous monitoring", J Cardiovasc Electrophysiol, 22, pp.369~375 (2011)
- Oral H, "Prevalence of asymptomatic recurrences of atrial fibrillation after successful radiofrequency catheter ablation", J Cardiovasc Electrophysiol, 15, pp.920~924 (2004)
- Karch MR, "Freedom from atrial tachyarrhythmias after catheter ablation of atrial fibrillation : a randomized comparison between 2 current ablation strategies", Circulation, 111, pp.2875~2880 (2005)
- Hindricks G, "Perception of atrial fibrillation before and after radiofrequency catheter ablation-Relevance of asymptomatic arrhythmia recurrence", Circulation, 112, pp.307~313 (2005)
- Tondo C, "Rhythm-symptom correlation in patients on continuous monitoring after catheter ablation of atrial fibrillation", J Cardiovasc Electrophysiol, 25, pp.154~160 (2014)
- Winkle RA, "Atrial arrhythmia burden on long-term monitoring in asymptomatic patients late after atrial fibrillation ablation", Am J Cardiol, 110, pp.840~844 (2012)
- Takagi T, "Role of extended external auto-triggered loop recorder monitoring for atrial fibrillation", Circ J, 78, pp.2637~2642 (2014)
- Pecha S, "Concomitant surgical atrial fibrillation ablation and event recorder implantation: better monitoring, better outcome", Interact Cardiovasc Thorac Surg, 16, pp.465~469 (2013)
- Kapa S, "Assessing arrhythmia burden after catheter ablation of atrial fibrillation using an implantable loop recorder : the ABACUS study", J Cardiovasc Electrophysiol, 24, pp.875~881 (2013)
- Damiano RJ Jr, "Detection of Atrial Fibrillation After Surgical Ablation:Conventional Versus Continuous Monitoring", Ann Thorac Surg, 101, pp.42~47 (2016)
- Dagres N, "Influence of the duration of Holter monitoring on the detection of arrhythmia recurrences after catheter ablation of atrial fibrillation: implications for patient follow-up", Int J Cardiol, 139, pp.305~306 (2010)
- Wokhlu A, "Long-Term Quality of Life After Ablation of Atrial Fibrillation. The Impact of Recurrence, Symptom Relief, and Placebo Effect", J Am Coll Cardiol, 55, pp.2308~2316 (2010)
- Piorkowski C, "Value of different follow-up strategies to assess the efficacy of circumferential pulmonary vein ablation for the curative treatment of atrial fibrillation", J Cardiovasc Electrophysiol, 16, pp.1286~1292 (2005)
- Janse PA, "Symptoms versus objective rhythm monitoring in patients with paroxysmal atrial fibrillation undergoing pulmonary vein isolation", Eur J Cardiovasc Nurs, 7, pp.147~151 (2008)
- Ziegler PD, "Comparison of continuous versus intermittent monitoring of atrial arrhythmias", Heart Rhythm, 3, pp.1445~1452 (2006)
- Edgerton JR, "Long-term monitoring after surgical ablation for atrial fibrillation: How much is enough", J Thorac Cardiovasc Surg, 142, pp.162~165 (2011)
- Mulder AAW, "Arrhythmia detection after atrial fibrillation ablation : Value of incremental monitoring time", PACE, 35, pp.164~169 (2012)
- JOSHI S, "Prevalence, Predictors, and Prognosis of Atrial Fibrillation Early After Pulmonary Vein Isolation : Findings from 3 Months of Continuous Automatic ECG Loop Recordings", J Cardiovasc Electrophysiol, 20, pp.1089~1094 (2009)
- Gussak I, "Wireless remote monitoring of reconstructed 12-lead ECGs after ablation for atrial fibrillation using a hand-held device", J Electrocardiol, 45, pp.129~135 (2012)
- Tarakji KG, "Using a novel wireless system for monitoring patients after the atrial fibrillation ablation procedure : The iTransmit study", Heart Rhythm, 12, pp.554~559 (2015)
- Hindricks G, "Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation : Results of the XPECT trial", Circ Arrhythm Electrophysiol, 3, pp.141~147 (2010)
- Bogachev-Prokophiev A, "Assessment of concomitant paroxysmal atrial fibrillation ablation in mitral valve surgery patients based on continuous monitoring : does a different lesion set matter?", Interact Cardiovasc Thorac Surg, 18, pp.177~182 (2014)
- Pokushalov E, "A Randomized Comparison of Pulmonary Vein Isolation With Versus Without Concomitant Renal Artery Denervation in Patients With Refractory Symptomatic Atrial Fibrillation and Resistant Hypertension", J Am Coll Cardiol, 60, pp.1163~1170 (2012)
- GERSAK B, "Low Rate of Atrial Fibrillation Recurrence Verified by Implantable Loop Recorder Monitoring Following a Convergent Epicardial and Endocardial Ablation of Atrial Fibrillation", J Cardiovasc Electrophysiol, 23, pp.1059~1066 (2012)
- Ad N, "The Cox-Maze III Procedure Success Rate : Comparison by Electrocardiogram, 24-Hour Holter Monitoring and Long-Term Monitoring", Ann Thorac Surg, 88, pp.101~105 (2009)
- Hanke T, "Twenty-Four–Hour Holter Monitor Follow-Up Does Not Provide Accurate Heart Rhythm Status After Surgical Atrial Fibrillation Ablation Therapy", Up to 12 Months Experience With a Novel Permanently Implantable Heart Rhythm Monitor Device, 120, pp.S177~S184 (2009)
- Liu J, "The value of transtelephonic electrocardiogram monitoring system during the"Blanking Period"after ablation of atrial fibrillation", J Electrocardiol, 43, pp.667~672 (2010)
- Bogachev-Prokophiev A, "Ablation for atrial fibrillation during mitral valve surgery : 1-year results through continuous subcutaneous monitoring†", Interact Cardiovasc Thorac Surg, 15, pp.37~41 (2012)
- Pokushalov E, "Does atrial fibrillation burden measured by continuous monitoring during the blanking period predict the response to ablation at 12-month follow-up", Heart Rhythm, 9, pp.1375~1379 (2012)
- Pérez-Castellano N, "The COR trial : A randomized study with continuous rhythm monitoring to compare the efficacy of cryoenergy and radiofrequency for pulmonary vein isolation", Heart Rhythm, 11, pp.8~14 (2014)
- Charitos EI, "Long-term outcomes after surgical ablation for atrial fibrillation in patients with continuous heart rhythm monitoring devices", Interact Cardiovasc Thorac Surg, 21, pp.712~721 (2015)
- Pecha S, "Implantable loop recorder monitoring after concomitant surgical ablation for atrial fibrillation(AF) : insights from more than 200 continuously monitored patients", Heart and Vessels, 31, pp.1347~1353 (2016)
- Eitel C, "Performance of an implantable automatic atrial fibrillation detection device : impact of software adjustments and relevance of manual episode analysis", EP Europace, 13, pp.480~485 (2011)
- Seidl K, "Is the Atrial High Rate Episode Diagnostic Feature Reliahle in Detecting Paroxysmal Episodes of Atrial Tachyarrhythmias", Pacing Clin Electrophysiol, 21, pp.694~700 (1998)
- Purerfellner H, "Accuracy of Atrial Tachyarrhythmia Detection in Implantable Devices with Arrhythmia Therapies", Pacing Clin Electrophysiol, 27, pp.983~992 (2004)
- Martinek M, "New Insights into Long‐Term Follow‐Up of Atrial Fibrillation Ablation : Full Disclosure by an Implantable Pacemaker Device", J Cardiovasc Electrophysiol, 18, pp.818~823 (2007)
- Steven D, "What is the real atrial fibrillation burden after catheter ablation of atrial fibrillation? A prospective rhythm analysis in pacemaker patients with continuous atrial monitoring", Eur Heart J, 29, pp.1037~1042 (2008)
- Puskas JD, ""Spot"ECGs underestimate atrial fibrillation recurrence after surgical ablation", Innovations(Phila), 3, pp.7~11 (2008)
- Kaufman ES, "Positive predictive value of device-detected atrial high-rate episodes at different rates and durations : An analysis from ASSERT", Heart Rhythm, 9, pp.1241~1246 (2012)
- Arbelo E, "The Atrial Fibrillation Ablation Pilot Study: an European Survey on Methodology and results of catheter ablation for atrial fibrillation conducted by the European Heart Rhythm Association", Eur Heart J, 35, pp.1466~1478 (2014)
- Andrade J, "The Clinical Profile and Pathophysiology of Atrial Fibrillation", Circ Res, 114, pp.1453~1468 (2014)
- Andrade JG, "Incidence and Significance of Early Recurrences of Atrial Fibrillation After Cryoballoon Ablation", Circ Arrhythm Electrophysiol, 7, pp.69~75 (2014)
- Andrade J, "The time course of exit and entrance block during cryoballoon pulmonary vein isolation", EP Europace, 16, pp.500~504 (2014)
- O’Donnell D, "Delayed cure despite early recurrence after pulmonary vein isolation for atrial fibrillation", Am J Cardiol, 91, pp.83~85 (2003)
- Jiang H, "Predictors of early recurrence and delayed cure after segmental pulmonary vein isolation for paroxysmal atrial fibrillation without structural heart disease", J Interv Card Electrophysiol, 15, pp.157~163 (2006)
- Richter B, "Frequency of Recurrence of Atrial Fibrillation Within 48Hours After Ablation and Its Impact on Long-Term Outcome", Am J Cardiol, 101, pp.843~847 (2008)
- Choi JI, "Clinical significance of early recurrences of atrial tachycardia after atrial fibrillation ablation", J Cardiovasc Electrophysiol, 21, pp.1331~1337 (2010)
- Reddy VY, "Balloon catheter ablation to treat paroxysmal atrial fibrillation: What is the level of pulmonary venous isolation", Heart Rhythm, 5, pp.353~360 (2008)
- Kirchhof P, "Outcome parameters for trials in atrial fibrillation : executive summary Recommendations from a consensus conference organized by the German Atrial Fibrillation Competence NETwork(AFNET)and the European Heart Rhythm Association(EHRA)", Eur Heart J, 28, pp.2803~2817 (2007)
- Saliba W, "Atrial Fibrillation Ablation Using a Robotic Catheter Remote Control System : Initial Human Experience and Long-Term Follow-Up Results", J Am Coll Cardiol, 51, pp.2407~2411 (2008)
- Issac TT, "Role of Inflammation in Initiation and Perpetuation of Atrial Fibrillation : A Systematic Review of the Published Data", J Am Coll Cardiol, pp.2021~2028 (2007)
- Andrade JG, "Early Recurrence of Atrial Tachyarrhythmias Following Radiofrequency Catheter Ablation of Atrial Fibrillation", Pacing Clin Electrophysiol, 35, pp.106~116 (2012)
- Li XP, "Predictive value of early recurrence and delayed cure after catheter ablation for patients with chronic atrial fibrillation", Circ J, 72, pp.1125~1129 (2008)
- Mugnai G, "Second-generation cryoballoon ablation for paroxysmal atrial fibrillation : Predictive role of atrial arrhythmias occurring in the blanking period on the incidence of late recurrences", Heart Rhythm, 13, pp.845~851 (2016)
- Roux J-F, "Antiarrhythmics After Ablation of Atrial Fibrillation(5A Study)", Circulation, 120, pp.1036~1040 (2009)
- Leong-Sit P, "Antiarrhythmics after ablation of atrial fibrillation(5A Study) : six-month follow-up study", Circ Arrhythm Electrophysiol, 4, pp.11~14 (2011)
- Koyama T, "Prevention of Atrial Fibrillation Recurrence With Corticosteroids After Radiofrequency Catheter Ablation : A Randomized Controlled Trial", J Am Coll Cardiol, 56, pp.1463~1472 (2010)
- Won H, "Effect of a single bolus injection of low-dose hydrocortisone for prevention of atrial fibrillation recurrence after radiofrequency catheter ablation", Circ J, 77, pp.53~59 (2013)
- Kim YR, "Effect of Short-Term Steroid Therapy on Early Recurrence During the Blanking Period After Catheter Ablation of Atrial Fibrillation", Circ Arrhythm Electrophysiol, 8, pp.1366~1372 (2015)
- Kim YR, "Effect of Short-Term Steroid Therapy on Early Recurrence during the Blanking Period after Catheter Ablation of Atrial Fibrillation", Circ Arrhythm Electrophysiol, 8, pp.1366~1372 (2015)
- Imazio M, "Colchicine reduces postoperative atrial fibrillation : results of the Colchicine for the Prevention of the Postpericardiotomy Syndrome(COPPS)atrial fibrillation substudy", Circulation, 124, pp.2290~2295 (2011)
- Deftereos S, "Colchicine for Prevention of Early Atrial Fibrillation Recurrence After Pulmonary Vein Isolation : A Randomized Controlled Study", J Am Coll Cardiol, 60, pp.1790~1796 (2012)
- Chilukuri K, "Outcomes in Patients Requiring Cardioversion Following Catheter Ablation of Atrial Fibrillation", J Cardiovasc Electrophysiol, 21, pp.27~32 (2010)
- Baman TS, "Time to Cardioversion of Recurrent Atrial Arrhythmias After Catheter Ablation of Atrial Fibrillation and Long‐Term Clinical Outcome", J Cardiovasc Electrophysiol, 20, pp.1321~1325 (2009)
- Malasana G, "A Strategy of Rapid Cardioversion Minimizes the Significance of Early Recurrent Atrial Tachyarrhythmias After Ablation for Atrial Fibrillation", J Cardiovasc Electrophysiol, 22, pp.761~766 (2011)
- Sponga S, "Role of an aggressive rhythm control strategy on sinus rhythm maintenance following intra-operative radiofrequency ablation of atrial fibrillation in patients undergoing surgical correction of valvular disease", Journal of Cardiology, 60, pp.316~320 (2012)
- Sairaku A, "Learning curve for ablation of atrial fibrillation in medium-volume centers", J Cardiol, 57, pp.263~268 (2011)
- Sairaku A, "How many electrical cardioversions should be applied for repetitive recurrences of atrial arrhythmias following ablation of persistent atrial fibrillation", EP Europace, 13, pp.1703~1708 (2011)
- Lellouche N, "Early Recurrences After Atrial Fibrillation Ablation : Prognostic Value and Effect of Early Reablation", J Cardiovasc Electrophysiol, 19, pp.599~605 (2008)
- Lee S-H, "Predictors of Early and Late Recurrence of Atrial Fibrillation after Catheter Ablation of Paroxysmal Atrial Fibrillation", J Interv Card Electrophysiol, 10, pp.221~226 (2004)
- Calkins H, "2012 HRS", EHRA, Heart Rhythm, pp.2012, 9[DOI]
- Brooks AG, "Outcomes of long-standing persistent atrial fibrillation ablation: A systematic review", Heart Rhythm, 7, pp.835~846 (2010)
- Anousheh R, "Effect of Mitral Isthmus Block on Development of Atrial Tachycardia Following Ablation for Atrial Fibrillation", Pacing Clin Electrophysiol, 33, pp.460~468 (2010)
- Lim TW, "Atrial arrhythmias after single-ring isolation of the posterior left atrium and pulmonary veins for atrial fibrillation : mechanisms and management", Circ Arrhythm Electrophysiol, 1, pp.120~126 (2008)
- Gerstenfeld EP, "Mapping and ablation of left atrial tachycardias occurring after atrial fibrillation ablation", Heart Rhythm, 4, pp.S65~S72 (2007)
- VIllacastín J, "Left Atrial Flutter After Radiofrequency Catheter Ablation of Focal Atrial Fibrillation", J Cardiovasc Electrophysiol, 14, pp.417~421 (2003)
- Oral H, "Left Atrial Flutter After Segmental Ostial Radiofrequency Catheter Ablation for Pulmonary Vein Isolation", Pacing Clin Electrophysiol, 26, pp.1417~1419 (2003)
- Thomas SP, "The effect of a residual isthmus of surviving tissue on conduction after linear ablation in atrial myocardium", J Interv Card Electrophysiol, 4, pp.273~281 (2000)
- Yang PS, "Which patients recur as atrial tachycardia rather than atrial fibrillation after catheter ablation of atrial fibrillation", PLoS One, 12, pp.e0188326~ (2017)
- Satomi K, "Electrophysiological Characteristics of Atrial Tachycardia After Pulmonary Vein Isolation of Atrial Fibrillation", Circ J, 74, pp.1051~1058 (2010)
- Nalliah CJ, "Clinical significance of early atrial arrhythmia type and timing after single ring isolation of the pulmonary veins", EP Europace, 17, pp.1038~1044 (2015)
- Themistoclakis S, "Clinical predictors and relationship between early and late atrial tachyarrhythmias after pulmonary vein antrum isolation", Heart Rhythm, 5, pp.679~685 (2008)
- Jaïs P, "Flutter Localized to the Anterior Left Atrium After Catheter Ablation of Atrial Fibrillation", J Cardiovasc Electrophysiol, 17, pp.279~285 (2006)
- Patel AM, "Atrial tachycardia after ablation of persistent atrial fibrillation : identification of the critical isthmus with a combination of multielectrode activation mapping and targeted entrainment mapping", Circ Arrhythm Electrophysiol, 1, pp.14~22 (2008)
- Jaïs P, "A Deductive Mapping Strategy for Atrial Tachycardia Following Atrial Fibrillation Ablation : Importance of Localized Reentry", J Cardiovasc Electrophysiol, 20, pp.480~491 (2009)
- Kang JH, "Prediction of long-term outcomes of catheter ablation of persistent atrial fibrillation by parameters of preablation DC cardioversion", J Cardiovasc Electrophysiol, 23, pp.1165~1170 (2012)
- Kang KW, "Additional linear ablation from the superior vena cava to right atrial septum after pulmonary vein isolation improves the clinical outcome in patients with paroxysmal atrial fibrillation : prospective randomized study", Europace, 16, pp.1738~1745 (2014)
- 박희남, "Clinical Significance of Additional Ablation of Atrial Premature Beats after Catheter Ablation for Atrial Fibrillation", Yonsei Medical Journal, 57(1), pp.72~80 (2016), 연세대학교의과대학[DOI]
- Kim MN, "The difference of predictors for recurrence after catheter ablation of non-paroxysmal atrial fibrillation according to follow-up period", Int Heart J, 55, pp.312~318 (2014)
- Kim TH, "Challenging Achievement of Bidirectional Block After Linear Ablation Affects the Rhythm Outcome in Patients With Persistent Atrial Fibrillation", J Am Heart Assoc, 5 (2016)
- Lee KN, "Long-Term Clinical Comparison of Procedural End Points After Pulmonary Vein Isolation in Paroxysmal Atrial Fibrillation: Elimination of Nonpulmonary Vein Triggers Versus Noninducibility", Circ Arrhythm Electrophysiol, 11, pp.e005019~ (2018)
- Yang PS, "High plasma level of soluble RAGE is independently associated with a low recurrence of atrial fibrillation after catheter ablation in diabetic patient", Europace, 18, pp.1711~1718 (2016)
- Al-Hijji MA, "Trends and predictors of repeat catheter ablation for atrial fibrillation", Am Heart J, 171, pp.48~55 (2016)
- Gerstenfeld EP, "Incidence and Location of Focal Atrial Fibrillation Triggers in Patients Undergoing Repeat Pulmonary Vein Isolation", J Cardiovasc Electrophysiol, 14, pp.685~690 (2003)
- Wasmer K, "Pulmonary vein reconnection and arrhythmia progression after antral linear catheter ablation of paroxysmal and persistent atrial fibrillation", Clin Res Cardiol, 105, pp.738~743 (2016)
- Kim TH, "Pulmonary vein reconnection predicts good clinical outcome after second catheter ablation for atrial fibrillation", Europace, 19, pp.961~967 (2017)
- Rolf S, "Voltage‐Based Ablation : The Growing Evidence for the Role of Individually Tailored Substrate Modification for Atrial Fibrillation", J Cardiovasc Electrophysiol, 27, pp.31~33 (2016)
- Bassiouny M, "Randomized Study of Persistent Atrial Fibrillation Ablation: Ablate in Sinus Rhythm Versus Ablate Complex-Fractionated Atrial Electrograms in Atrial Fibrillation", Circ Arrhythm Electrophysiol, 9, pp.e003596~ (2016)
- Hsieh M-H, "Alterations of Heart Rate Variability After Radiofrequency Catheter Ablation of Focal Atrial Fibrillation Originating From Pulmonary Veins", Circulation, 100, pp.2237~2243 (1999)
- Kang KW, "Long-term changes in heart rate variability after radiofrequency catheter ablation for atrial fibrillation : 1-year follow-up study with irrigation tip catheter", J Cardiovasc Electrophysiol, 25, pp.693~700 (2014)
- Dumonceau JM, "Acute Delayed Gastric Emptying after Ablation of Atrial Fibrillation : Treatment with Botulinum Toxin Injection", Endoscopy, 38, pp.543~543 (2006)
- Bunch TJ, "Vagus nerve injury after posterior atrial radiofrequency ablation", Heart Rhythm, 5, pp.1327~1330 (2008)
- Kuwahara T, "Clinical Characteristics and Management of Periesophageal Vagal Nerve Injury Complicating Left Atrial Ablation of Atrial Fibrillation: Lessons from Eleven Cases", J Cardiovasc Electrophysiol, 24, pp.847~851 (2013)
- Miyazaki S, "Factors Associated With Periesophageal Vagal Nerve Injury After Pulmonary Vein Antrum Isolation", J Am Heart Assoc, 3 (2014)
- Lakkireddy D, "Effect of Atrial Fibrillation Ablation on Gastric Motility: The Atrial Fibrillation Gut Study", Circ Arrhythm Electrophysiol, 8, pp.531~536 (2015)
- Steinberg JS, "Very long-term outcome after initially successful catheter ablation of atrial fibrillation", Heart Rhythm, 11, pp.771~776 (2014)
- Sotomi Y, "Incidence and risk factors for very late recurrence of atrial fibrillation after radiofrequency catheter ablation", EP Europace, 15, pp.1581~1586 (2013)
- Bertaglia E, "Does catheter ablation cure atrial fibrillation? Single-procedure outcome of drug-refractory atrial fibrillation ablation : a 6-year multicentre experience", EP Europace, 12, pp.181~187 (2010)
- Wokhlu A, "Long-Term Quality of Life After Ablation of Atrial Fibrillation : The Impact of Recurrence, Symptom Relief, and Placebo Effect", J Am Coll Cardiol, 55, pp.2308~2316 (2010)
- Baek YS, "Delayed recurrence of atrial fibrillation 2years after catheter ablation is associated with metabolic syndrome", Int J Cardiol, 223, pp.276~281 (2016)
- Packer DL, "Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation : first results of the North American Arctic Front(STOP AF)pivotal trial", J Am Coll Cardiol, 61, pp.1713~1723 (2013)
- Shah AJ, "Comparison of rhythm restoration strategies in paroxysmal atrial fibrillation", Expert Rev Cardiovasc Ther, 8, pp.903~906 (2010)
- Natale A, "Paroxysmal AF catheter ablation with a contact force sensing catheter : results of the prospective, multicenter SMART-AF trial", J Am Coll Cardiol, 64, pp.647~656 (2014)
- Reddy VY, "Randomized, Controlled Trial of the Safety and Effectiveness of a Contact Force-Sensing Irrigated Catheter for Ablation of Paroxysmal Atrial Fibrillation : Results of the TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation(TOCCASTAR)Study", Circulation, 132, pp.907~915 (2015)
- Dukkipati SR, "Pulmonary Vein Isolation Using the Visually Guided Laser Balloon : A Prospective, Multicenter, and Randomized Comparison to Standard Radiofrequency Ablation", J Am Coll Cardiol, 66, pp.1350~1360 (2015)
- Hummel J, "Phased RF ablation in persistent atrial fibrillation", Heart rhythm, 11, pp.202~209 (2014)
- Hakalahti A, "Radiofrequency ablation vs. antiarrhythmic drug therapy as first line treatment of symptomatic atrial fibrillation: systematic review and meta-analysis", Europace, 17, pp.370~378 (2015)
- Wazni OM, "Radiofrequency ablation vs antiarrhythmic drugs as first-line treatment of symptomatic atrial fibrillation : a randomized trial", Jama, 293, pp.2634~2640 (2005)
- Cosedis Nielsen J, "Radiofrequency ablation as initial therapy in paroxysmal atrial fibrillation", N Engl J Med, 367, pp.1587~1595 (2012)
- Morillo CA, "Radiofrequency ablation vs antiarrhythmic drugs as first-line treatment of paroxysmal atrial fibrillation(RAAFT-2) : a randomized trial", Jama, 311, pp.692~700 (2014)
- Pappone C, "A randomized trial of circumferential pulmonary vein ablation versus antiarrhythmic drug therapy in paroxysmal atrial fibrillation : the APAF Study", J Am Coll Cardiol, 48, pp.2340~2347 (2006)
- Jais P, "Catheter ablation versus antiarrhythmic drugs for atrial fibrillation : the A4 study", Circulation, 118, pp.2498~2505 (2008)
- Kuck KH, "Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation", N Engl J Med, 374, pp.2235~2245 (2016)
- Sohara H, "HotBalloon Ablation of the Pulmonary Veins for Paroxysmal AF : A Multicenter Randomized Trial in Japan", J Am Coll Cardiol, 68, pp.2747~2757 (2016)
- Wokhlu A, "Longterm outcome of atrial fibrillation ablation : impact and predictors of very late recurrence", J Cardiovasc Electrophysiol, 21, pp.1071~1078 (2010)
- Verma A, "Approaches to catheter ablation for persistent atrial fibrillation", N Engl J Med, 372, pp.1812~1822 (2015)
- Oral H, "Circumferential pulmonaryvein ablation for chronic atrial fibrillation", N Engl J Med, 354, pp.934~941 (2006)
- Mont L, "Catheter ablation vs. antiarrhythmic drug treatment of persistent atrial fibrillation:a multicentre, randomized, controlled trial (SARA study)", Eur Heart J, 35, pp.501~507 (2014)
- Krittayaphong R, "A randomized clinical trial of the efficacy of radiofrequency catheter ablation and amiodarone in the treatment of symptomatic atrial fibrillation", J Med Assoc Thai, 86(Suppl 1), pp.S8~S16 (2003)
- Stabile G, "Catheter ablation treatment in patients with drug-refractory atrial fibrillation : a prospective, multi-centre, randomized, controlled study(Catheter Ablation For The Cure Of Atrial Fibrillation Study)", Eur Heart J, 27, pp.216~221 (2006)
- Forleo GB, "Catheter ablation of atrial fibrillation in patients with diabetes mellitus type 2 : results from a randomized study comparing pulmonary vein isolation versus antiarrhythmic drug therapy", J Cardiovasc Electrophysiol, 20, pp.22~28 (2009)
- Halabi S, "Catheter Ablation for Atrial Fibrillation in Heart Failure Patients", JACC Clin Electrophysiol, 1, pp.200~209 (2015)
- Khan MN, "Pulmonary-vein isolation for atrial fibrillation in patients with heart failure", N Engl J Med, 359, pp.1778~1785 (2008)
- MacDonald MR, "Radiofrequency ablation for persistent atrial fibrillation in patients with advanced heart failure and severe left ventricular systolic dysfunction : a randomised controlled trial", Heart, 97, pp.740~747 (2011)
- Jones DG, "A randomized trial to assess catheter ablation versus rate control in the management of persistent atrial fibrillation in heart failure", J Am Coll Cardiol, 61, pp.1894~1903 (2013)
- Hunter RJ, "A randomized controlled trial of catheter ablation versus medical treatment of atrial fibrillation in heart failure(the CAMTAF trial)", Circ Arrhythm Electrophysiol, 7, pp.31~38 (2014)
- Marrouche NF, "Catheter Ablation for Atrial Fibrillation with Heart Failure", N Engl J Med, 378, pp.417~427 (2018)
- Olivotto I, "Impact of atrial fibrillation on the clinical course of hypertrophic cardiomyopathy", Circulation, 104, pp.2517~2524 (2001)
- Providencia R, "Catheter ablation for atrial fibrillation in hypertrophic cardiomyopathy : a systematic review and metaanalysis", Heart, 102, pp.1533~1543 (2016)
- Chun KR, "Catheter ablation of atrial fibrillation in the young : insights from the German Ablation Registry", Clin Res Cardiol, 102, pp.459~468 (2013)
- Siontis KC, "Radiofrequency Ablation Versus Antiarrhythmic Drug Therapy for Atrial Fibrillation", JACC, 2, pp.170~180 (2016)
- Pappone C, "Atrial electroanatomic remodeling after circumferential radiofrequency pulmonary vein ablation : efficacy of an anatomic approach in a large cohort of patients with atrial fibrillation", Circulation, 104, pp.2539~2544 (2001)
- Scharf C, "Anatomy of the pulmonary veins in patients with atrial fibrillation and effects of segmental ostial ablation analyzed by computed tomography", J Cardiovasc Electrophysiol, 14, pp.150~155 (2003)
- ayam VK, "Atrial volume reduction following catheter ablation of atrial fibrillation and relation to reduction in pulmonary vein size : an evaluation using magnetic resonance angiography", J Interv Card Electrophysiol, 13, pp.107~114 (2005)
- Tsao HM, "Morphologic remodeling of pulmonary veins and left atrium after catheter ablation of atrial fibrillation : insight from long-term follow-up of three-dimensional magnetic resonance imaging", J Cardiovasc Electrophysiol, 16, pp.7~12 (2005)
- Gibson DN, "Stiff left atrial syndrome after catheter ablation for atrial fibrillation : clinical characterization, prevalence, and predictors", Heart rhythm, 8, pp.1364~1371 (2011)
- Dagres N, "Catheter ablation for atrial fibrillation in patients with left ventricular systolic dysfunction. A systematic review and metaanalysis", J Card Fail, 17, pp.964~970 (2011)
- Friberg L, "Catheter ablation for atrial fibrillation is associated with lower incidence of stroke and death : data from Swedish health registries", Eur Heart J, 37, pp.2478~2487 (2016)
- Chang CH, "Effect of radiofrequency catheter ablation for atrial fibrillation on morbidity and mortality : a nationwide cohort study and propensity score analysis", Circ Arrhythm Electrophysiol, 7, pp.76~82 (2014)
- Berruezo A, "Pre-procedural predictors of atrial fibrillation recurrence after circumferential pulmonary vein ablation", Eur Heart J, 28, pp.836~841 (2007)
- Arya A, "Long-term results and the predictors of outcome of catheter ablation of atrial fibrillation using steerable sheath catheter navigation after single procedure in 674 patients", Europace, 12, pp.173~180 (2010)
- Marrouche NF, "Association of atrial tissue fibrosis identified by delayed enhancement MRI and atrial fibrillation catheter ablation : the DECAAF study", Jama, 311, pp.498~506 (2014)
- Abecasis J, "Left atrial volume calculated by multi-detector computed tomography may predict successful pulmonary vein isolation in catheter ablation of atrial fibrillation", Europace, 11, pp.1289~1294 (2009)
- McCready JW, "Predictors of recurrence following radiofrequency ablation for persistent atrial fibrillation", Europace, 13, pp.355~361 (2011)
- D'Ascenzo F, "Which are the most reliable predictors of recurrence of atrial fibrillation after transcatheter ablation? : a meta-analysis", Int J Cardiol, 167, pp.1984~1989 (2013)
- Balk EM, "Predictors of atrial fibrillation recurrence after radiofrequency catheter ablation : a systematic review", J Cardiovasc Electrophysiol, 21, pp.1208~1216 (2010)
- Deshmukh A, "In-hospital complications associated with catheter ablation of atrial fibrillation in the United States between 2000 and 2010 : analysis of 93 801 procedures", Circulation, 128, pp.2104~2112 (2013)
- Cappato R, "Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation", Circ Arrhythm Electrophysiol, 3, pp.32~38 (2010)
- Di Biase L, "Periprocedural stroke and management of major bleeding complications in patients undergoing catheter ablation of atrial fibrillation : the impact of periprocedural therapeutic international normalized ratio", Circulation, 121, pp.2550~2556 (2010)
- Latchamsetty R, "Management and outcomes of cardiac tamponade during atrial fibrillation ablation in the presence of therapeutic anticoagulation with warfarin", Heart Rhythm, 8, pp.805~808 (2011)
- Calkins H, "RE-CIRCUIT studyrandomized evaluation of Dabigatran etexilate compared to warfarin in pulmonary vein ablation : assessment of an uninterrupted periprocedural anticoagulation strategy", Am J Cardiol, 115, pp.154~155 (2015)
- Wu S, "Meta-Analysis of Efficacy and Safety of New Oral Anticoagulants Compared With Uninterrupted Vitamin K Antagonists in Patients Undergoing Catheter Ablation for Atrial Fibrillation", Am J Cardiol, 117, pp.926~934 (2016)
- Michowitz Y, "Effects of sex on the incidence of cardiac tamponade after catheter ablation of atrial fibrillation : results from a worldwide survey in 34 943 atrial fibrillation ablation procedures", Circ Arrhythm Electrophysiol, 7, pp.274~280 (2014)
- Andrade JG, "Efficacy and safety of cryoballoon ablation for atrial fibrillation : a systematic review of published studies", Heart Rhythm, 8, pp.1444~1451 (2011)
- Kuck KH, "Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation", N Engl J Med, 374, pp.2235~2245 (2016)
- Natale A, "Paroxysmal AF catheter ablation with a contact force sensing catheter : results of the prospective, multicenter SMART-AF trial", J Am Coll Cardiol, 64, pp.647~656 (2014)
- Reddy VY, "Randomized, Controlled Trial of the Safety and Effectiveness of a Contact Force-Sensing Irrigated Catheter for Ablation of Paroxysmal Atrial Fibrillation : Results of the TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation(TOCCASTAR)Study", Circulation, 132, pp.907~915 (2015)
- Cappato R, "Delayed cardiac tamponade after radiofrequency catheter ablation of atrial fibrillation : a worldwide report", J Am Coll Cardiol, 58, pp.2696~2697 (2011)
- Pollack CV Jr, "Idarucizumab for Dabigatran Reversal", N Engl J Med, 373, pp.511~520 (2015)
- Siegal DM, "Andexanet Alfa for the Reversal of Factor Xa Inhibitor Activity", N Engl J Med, 373, pp.2413~2424 (2015)
- Tsang TS, "Consecutive 1127therapeutic echocardiographically guided pericardiocenteses : clinical profile, practice patterns, and outcomes spanning 21years", Mayo Clin Proc, 77, pp.429~436 (2002)
- Bunch TJ, "Outcomes after cardiac perforation during radiofrequency ablation of the atrium", J Cardiovasc Electrophysiol, 16, pp.1172~1179 (2005)
- Wazni OM, "Embolic events and char formation during pulmonary vein isolation in patients with atrial fibrillation : impact of different anticoagulation regimens and importance of intracardiac echo imaging", J Cardiovasc Electrophysiol, 16, pp.576~581 (2005)
- Gaita F, "Incidence of silent cerebral thromboembolic lesions after atrial fibrillation ablation may change according to technology used : comparison of irrigated radiofrequency, multipolar nonirrigated catheter and cryoballoon", J Cardiovasc Electrophysiol, 22, pp.961~968 (2011)
- Di Biase L, "Esophageal capsule endoscopy after radiofrequency catheter ablation for atrial fibrillation : documented higher risk of luminal esophageal damage with general anesthesia as compared with conscious sedation", Circ Arrhythm Electrophysiol, 2, pp.108~112 (2009)
- Takahashi Y, "Acute occlusion of the left circumflex coronary artery during mitral isthmus linear ablation", J Cardiovasc Electrophysiol, 16, pp.1104~1107 (2005)
- Lakkireddy D, "Effect of atrial fibrillation ablation on gastric motility : the atrial fibrillation gut study", Circ Arrhythm Electrophysiol, 8, pp.531~536 (2015)
- Tavernier R, "Fracture of a circular mapping catheter after entrapment in the mitral valve apparatus during segmental pulmonary vein isolation", Pacing Clin Electrophysiol, 26, pp.1774~1775 (2003)
- Deftereos S, "Colchicine for prevention of early atrial fibrillation recurrence after pulmonary vein isolation : a randomized controlled study", J Am Coll Cardiol, 60, pp.1790~1796 (2012)
- Packer DL, "Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation : first results of the North American Arctic Front(STOP AF)pivotal trial", J Am Coll Cardiol, 61, pp.1713~1723 (2013)
- Pappone C, "Circumferential radiofrequency ablation of pulmonary vein ostia : A new anatomic approach for curing atrial fibrillation", Circulation, 102, pp.2619~2628 (2000)
- Caponi D, "Ablation of atrial fibrillation: does the addition of three-dimensional magnetic resonance imaging of the left atrium to electroanatomic mapping improve the clinical outcome?: a randomized comparison of Carto-Merge vs. Carto-XP threedimensional mapping ablation in patients with paroxysmal and persistent atrial fibrillation", Europace, 12, pp.1098~1104 (2010)
- Cochet H, "Atrial structure and function 5 years after successful ablation for persistent atrial fibrillation : an MRI study", J Cardiovasc Electrophysiol, 25, pp.671~679 (2014)
- Ghanbari H, "Mortality and cerebrovascular events after radiofrequency catheter ablation of atrial fibrillation", Heart Rhythm, 11, pp.1503~1511 (2014)
- Cappato R, "Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation", Circulation, 111, pp.1100~1105 (2005)
- Taylor GW, "Pathological effects of extensive radiofrequency energy applications in the pulmonary veins in dogs", Circulation, 101, pp.1736~1742 (2000)
- Dukkipati SR, "Pulmonary vein isolation using a visually guided laser balloon catheter : the first 200-patient multicenter clinical experience", Circ Arrhythm Electrophysiol, 6, pp.467~472 (2013)
- Arentz T, "Incidence of pulmonary vein stenosis 2 years after radiofrequency catheter ablation of refractory atrial fibrillation", Eur Heart J, 24, pp.963~969 (2003)
- Saad EB, "Pulmonary vein stenosis after catheter ablation of atrial fibrillation : emergence of a new clinical syndrome", Ann Intern Med, 138, pp.634~638 (2003)
- Holmes DR Jr, "Pulmonary vein stenosis complicating ablation for atrial fibrillation : clinical spectrum and interventional considerations", JACC Cardiovasc Interv, 2, pp.267~276 (2009)
- Hilbert S, "Pulmonary vein collateral formation as a long-term result of post-interventional pulmonary vein stenosis", Eur Heart J, 37, pp.2474~ (2016)
- Hilbert S, "Pulmonary vein dilatation in a case of total pulmonary vein occlusion: Contemporary approach using a combination of 3D-mapping system and image integration", Catheter Cardiovasc Interv, 88, pp.E227~E232 (2016)
- Katz ES, "Surgical left atrial appendage ligation is frequently incomplete : a transesophageal echocardiograhic study", J Am Coll Cardiol, 36, pp.468~471 (2000)
- Kumar S, "Esophageal hematoma after atrial fibrillation ablation : incidence, clinical features, and sequelae of esophageal injury of a different sort", Circ Arrhythm Electrophysiol, 5, pp.701~705 (2012)
- Cappato R, "Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation", Circulation, 111, pp.1100~1105 (2005)
- Nolker G, "Esophageal acid levels after pulmonary vein isolation for atrial fibrillation", Pacing Clin Electrophysiol, 32(Suppl 1), pp.S228~S230 (2009)
- Rillig A, "Modified energy settings are mandatory to minimize oesophageal injury using the novel multipolar irrigated radiofrequency ablation catheter for pulmonary vein isolation", Europace, 17, pp.396~402 (2015)
- Martinek M, "Identification of a high-risk population for esophageal injury during radiofrequency catheter ablation of atrial fibrillation : procedural and anatomical considerations", Heart Rhythm, 7, pp.1224~1230 (2010)
- Chavez P, "Atrioesophageal fistula following ablation procedures for atrial fibrillation:systematic review of case reports", Open Heart, 2, pp.e000257~ (2015)
- Mateos JC, "Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation--prospective study of 704 cases", Rev Bras Cir Cardiovasc, 30, pp.139~147 (2015)
- Mohanty S, "Outcomes of atrio-esophageal fistula following catheter ablation of atrial fibrillation treated with surgical repair versus esophageal stenting", J Cardiovasc Electrophysiol, 25, pp.E6~ (2014)
- Schwartz TW, "Pancreatic-polypeptide response to food in duodenalulcer patients before and after vagotomy", Lancet, 1, pp.1102~1105 (1976)
- Jones MP, "A systematic review of surgical therapy for gastroparesis", Am J Gastroenterol, 98, pp.2122~2129 (2003)
- Miyazaki S, "Factors associated with periesophageal vagal nerve injury after pulmonary vein antrum isolation", J Am Heart Assoc, 3, pp.e001209~ (2014)
- Janssens J, "Improvement of gastric emptying in diabetic gastroparesis by erythromycin. Preliminary studies", N Engl J Med, 322, pp.1028~1031 (1990)
- Dukkipati SR, "Pulmonary Vein Isolation Using the Visually Guided Laser Balloon : A Prospective, Multicenter, and Randomized Comparison to Standard Radiofrequency Ablation", J Am Coll Cardiol, 66, pp.1350~1360 (2015)
- Sohara H, "Feasibility of the radiofrequency hot balloon catheter for isolation of the posterior left atrium and pulmonary veins for the treatment of atrial fibrillation", Circ Arrhythm Electrophysiol, 2, pp.225~232 (2009)
- Andrade JG, "Efficacy and safety of cryoballoon ablation for atrial fibrillation : a systematic review of published studies", Heart Rhythm, 8, pp.1444~1451 (2011)
- Arruda M, "Electrical isolation of the superior vena cava : an adjunctive strategy to pulmonary vein antrum isolation improving the outcome of AF ablation", J Cardiovasc Electrophysiol, 18, pp.1261~1266 (2007)
- Yong Ji S, "Phrenic nerve injury : An underrecognized and potentially preventable complication of pulmonary vein isolation using a wide-area circumferential ablation approach", J Cardiovasc Electrophysiol, 24, pp.1086~1091 (2013)
- Franceschi F, "Phrenic nerve monitoring with diaphragmatic electromyography during cryoballoon ablation for atrial fibrillation : the first human application", Heart Rhythm, 8, pp.1068~1071 (2011)
- Patel D, "Longterm functional and neurocognitive recovery in patients who had an acute cerebrovascular event secondary to catheter ablation for atrial fibrillation", J Cardiovasc Electrophysiol, 21, pp.412~417 (2010)
- Ren JF, "Real-time intracardiac echocardiographic imaging of the posterior left atrial wall contiguous to anterior wall of the esophagus", J Am Coll Cardiol, 48, pp.594~ (2006)
- Deneke T, "Silent cerebral events", lesions related to atrial fibrillation ablation : a clinical review, 2015, pp.26, 455~463
- Gaita F, "Radiofrequency catheter ablation of atrial fibrillation : a cause of silent thromboembolism? Magnetic resonance imaging assessment of cerebral thromboembolism in patients undergoing ablation of atrial fibrillation", Circulation, 122, pp.1667~1673 (2010)
- Bendszus M, "Silent cerebral ischaemia : hidden fingerprints of invasive medical procedures", Lancet Neurol, 5, pp.364~372 (2006)
- Cauchemez B, "High-flow perfusion of sheaths for prevention of thromboembolic complications during complex catheter ablation in the left atrium", J Cardiovasc Electrophysiol, 15, pp.276~283 (2004)
- Kuwahara T, "Clinical characteristics of massive air embolism complicating left atrial ablation of atrial fibrillation : lessons from five cases", Europace, 14, pp.204~208 (2012)
- Franzen OW, "Mechanisms underlying air aspiration in patients undergoing left atrial catheterization", Catheter Cardiovasc Interv, 71, pp.553~558 (2008)
- Di Biase L, "Periprocedural stroke and bleeding complications in patients undergoing catheter ablation of atrial fibrillation with different anticoagulation management : results from the Role of Coumadin in Preventing Thromboembolism in Atrial Fibrillation(AF)Patients Undergoing Catheter Ablation(COMPARE)randomized trial", Circulation, 129, pp.2638~2644 (2014)
- Armbruster HL, "Safety of novel oral anticoagulants compared with uninterrupted warfarin for catheter ablation of atrial fibrillation", Ann Pharmacother, 49, pp.278~284 (2015)
- Tanaka-Esposito CC, "Real-time ultrasound guidance reduces total and major vascular complications in patients undergoing pulmonary vein antral isolation on therapeutic warfarin", J Interv Card Electrophysiol, 37, pp.163~168 (2013)
- Chugh A, "Manifestations of coronary arterial injury during catheter ablation of atrial fibrillation and related arrhythmias", Heart Rhythm, 10, pp.1638~1645 (2013)
- Takahashi Y, "Acute occlusion of the left circumflex coronary artery during mitral isthmus linear ablation", J Cardiovasc Electrophysiol, 16, pp.1104~1107 (2005)
- Kitamura T, "Transient sinus node dysfunction following sinus node artery occlusion due to radiofrequency catheter ablation of the septal superior vena cavaright atrium junction", J Electrocardiol, 49, pp.18~22 (2016)
- Sticherling C, "Thrombo-embolic occlusion of the left anterior descending coronary artery complicating left atrial radiofrequency ablation", Europace, 11, pp.117~118 (2009)
- Fayad G, "Circumflex artery stenosis induced by intraoperative radiofrequency ablation", Ann Thorac Surg, 76, pp.1291~1293 (2003)
- Lickfett L, "Radiation exposure during catheter ablation of atrial fibrillation", Circulation, 110, pp.3003~3010 (2004)
- Stabile G, "Reduced fluoroscopy exposure during ablation of atrial fibrillation using a novel electroanatomical navigation system : a multicentre experience", Europace, 14, pp.60~65 (2012)
- Dragusin O, "Evaluation of a radiation protection cabin for invasive electrophysiological procedures", Eur Heart J, 28, pp.183~189 (2007)
- Andrade JG, "Incidence and significance of early recurrences associated with different ablation strategies for AF : a STAR-AF substudy", J Cardiovasc Electrophysiol, 23, pp.1295~1301 (2012)
- Stabile G, "Low incidence of permanent complications during catheter ablation for atrial fibrillation using open-irrigated catheters : a multicentre registry", Europace, 16, pp.1154~1159 (2014)
- Luckie M, "Dressler's syndrome following pulmonary vein isolation for atrial fibrillation", Acute Card Care, 10, pp.234~235 (2008)
- 김다래, "Comparison of Two Different Doses of Single Bolus Steroid Injection to Prevent Atrial Fibrillation Recurrence after Radiofrequency Catheter Ablation", Yonsei Medical Journal, 56(2), pp.324~331 (2015), 연세대학교의과대학[DOI]
- Deftereos S, "Colchicine for prevention of atrial fibrillation recurrence after pulmonary vein isolation : midterm efficacy and effect on quality of life", Heart Rhythm, 11, pp.620~628 (2014)
- Cappato R, "Prevalence and causes of fatal outcome in catheter ablation of atrial fibrillation", J Am Coll Cardiol, 53, pp.1798~1803 (2009)
- Piccini JP, "Outcomes of Medicare beneficiaries undergoing catheter ablation for atrial fibrillation", Circulation, 126, pp.2200~2207 (2012)
- Welch TD, "Symptomatic pulmonary hypertension with giant left atrial v waves after surgical maze procedures : evaluation by comprehensive hemodynamic catheterization", Heart Rhythm, 10, pp.1839~1842 (2013)
- Witt C, "Recurrent dyspnea following multiple ablations for atrial fibrillation explained by the "stiff left atrial syndrome"", Catheter Cardiovasc Interv, 82, pp.E747~E749 (2013)
- Packer DL, "Clinical presentation, investigation, and management of pulmonary vein stenosis complicating ablation for atrial fibrillation", Circulation, 111, pp.546~554 (2005)
- Aryana A, "Impact of Pulmonary Vein Cryoballoon Ablation on Bronchial Injury", J Cardiovasc Electrophysiol, 27, pp.861~867 (2016)
- Verma N, "Ice formation in the left mainstem bronchus during cryoballoon ablation for the treatment of atrial fibrillation", Heart Rhythm, 13, pp.814~815 (2016)
- Scherlag BJ, "Autonomically induced conversion of pulmonary vein focal firing into atrial fibrillation", J Am Coll Cardiol, 45, pp.1878~1886 (2005)
- Bauer A, "Effects of circumferential or segmental pulmonary vein ablation for paroxysmal atrial fibrillation on cardiac autonomic function", Heart Rhythm, 3, pp.1428~1435 (2006)
- De Ponti R, "Simulator training reduces radiation exposure and improves trainees' performance in placing electrophysiologic catheters during patient-based procedures", Heart Rhythm, 9, pp.1280~1285 (2012)
- De Ponti R, "Superiority of simulator-based training compared with conventional training methodologies in the performance of transseptal catheterization", J Am Coll Cardiol, 58, pp.359~363 (2011)
- Talbot H, "Interactive training system for interventional electrocardiology procedures", Med Image Anal, 35, pp.225~237 (2017)
- Zipes DP, "2015 ACC", AHA, AHA 2006 Update of the Clinical Competence Statement on Invasive Electrophysiology Studies, Catheter Ablation, and Cardioversion), pp.Heart Rhythm, 2016[DOI]
- Sairaku A, "Learning curve for ablation of atrial fibrillation in medium-volume centers", J Cardiol, 57, pp.263~268 (2011)
- Perrotta L, "How to learn pulmonary vein isolation with a novel ablation device : learning curve effects using the endoscopic ablation system", J Cardiovasc Electrophysiol, 25, pp.1293~1298 (2014)
- Wojcik M, "Learning curve in cryoballoon ablation of atrial fibrillation : eight-year experience", Circ J, 78, pp.1612~1618 (2014)
- Martirosyan M, "Learning curve in circular multipolar phased radiofrequency ablation of atrial fibrillation", Cardiol J, 22, pp.260~266 (2015)
- Cappato R, "Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation", Circ Arrhythm Electrophysiol, 3, pp.32~38 (2010)
- Cappato R, "Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation", Circulation, 111, pp.1100~1105 (2005)
- Deshmukh A, "In-hospital complications associated with catheter ablation of atrial fibrillation in the United States between 2000 and 2010 : analysis of 93 801 procedures", Circulation, 128, pp.2104~2112 (2013)
- De Ponti R, "Simulator training reduces radiation exposure and improves trainees' performance in placing electrophysiologic catheters during patient-based procedures", Heart Rhythm, 9, pp.1280~1285 (2012)
- De Ponti R, "Superiority of simulator-based training compared with conventional training methodologies in the performance of transseptal catheterization", J Am Coll Cardiol, 58, pp.359~363 (2011)
- Talbot H, "Interactive training system for interventional electrocardiology procedures", Med Image Anal, 35, pp.225~237 (2017)
- Zipes DP, "2015 ACC", AHA, AHA 2006 Update of the Clinical Competence Statement on Invasive Electrophysiology Studies, Catheter Ablation, and Cardioversion), pp.Heart Rhythm, 2016[DOI]
- Sairaku A, "Learning curve for ablation of atrial fibrillation in medium-volume centers", J Cardiol, 57, pp.263~268 (2011)
- Perrotta L, "How to learn pulmonary vein isolation with a novel ablation device : learning curve effects using the endoscopic ablation system", J Cardiovasc Electrophysiol, 25, pp.1293~1298 (2014)
- Wojcik M, "Learning curve in cryoballoon ablation of atrial fibrillation : eight-year experience", Circ J, 78, pp.1612~1618 (2014)
- Martirosyan M, "Learning curve in circular multipolar phased radiofrequency ablation of atrial fibrillation", Cardiol J, 22, pp.260~266 (2015)
- Cappato R, "Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation", Circ Arrhythm Electrophysiol, 3, pp.32~38 (2010)
- Cappato R, "Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation", Circulation, 111, pp.1100~1105 (2005)
- Deshmukh A, "In-hospital complications associated with catheter ablation of atrial fibrillation in the United States between 2000 and 2010 : analysis of 93 801 procedures", Circulation, 128, pp.2104~2112 (2013)
- Badhwar V, "The Society of Thoracic Surgeons Mitral Repair", Replacement Composite Score : A Report of The Society of Thoracic Surgeons Quality Measurement Task Force, 2016, pp.101, 2265~2271
- Abreu Filho CA, "Effectiveness of the maze procedure using cooled-tip radiofrequency ablation in patients with permanent atrial fibrillation and rheumatic mitral valve disease", Circulation, 112, pp.120~125 (2005)
- Doukas G, "Left atrial radiofrequency ablation during mitral valve surgery for continuous atrial fibrillation : a randomized controlled trial", JAMA, 294, pp.2323~2329 (2005)
- Blomstrom-Lundqvist C, "A randomized double-blind study of epicardial left atrial cryoablation for permanent atrial fibrillation in patients undergoing mitral valve surgery : the SWEDish Multicentre Atrial Fibrillation study(SWEDMAF)", Eur Heart J, 28, pp.2902~2908 (2007)
- Chevalier P, "Left atrial radiofrequency ablation during mitral valve surgery : a prospective randomized multicentre study(SAFIR)", Arch Cardiovasc Dis, 102, pp.769~775 (2009)
- Cheng DC, "Surgical ablation for atrial fibrillation in cardiac surgery : a meta-analysis and systematic review", Innovations(Phila), 5, pp.84~96 (2010)
- Budera P, "Comparison of cardiac surgery with left atrial surgical ablation vs. cardiac surgery without atrial ablation in patients with coronary and", or valvular heart disease plus atrial fibrillation:final results of the PRAGUE-12 randomized multicentre study, 2012, pp.33, 2644~2652
- Phan K, "Surgical ablation for treatment of atrial fibrillation in cardiac surgery : a cumulative meta-analysis of randomised controlled trials", Heart, 100, pp.722~730 (2014)
- Gillinov AM, "Surgical ablation of atrial fibrillation during mitral-valve surgery", N Engl J Med, 372, pp.1399~1409 (2015)
- Rankin JS, "The Society of Thoracic Surgeons risk model for operative mortality after multiple valve surgery", Ann Thorac Surg, 95, pp.1484~1490 (2013)
- Louagie Y, "Improved patient survival with concomitant Cox Maze III procedure compared with heart surgery alone", Ann Thorac Surg, 87, pp.440~446 (2009)
- Chiappini B, "Radiofrequency ablation for atrial fibrillation : different approaches", Asian Cardiovasc Thorac Ann, 12, pp.272~277 (2004)
- Barnett SD, "Surgical ablation as treatment for the elimination of atrial fibrillation : a meta-analysis", J Thorac Cardiovasc Surg, 131, pp.1029~1035 (2006)
- Edgerton JR, "A new epicardial lesion set for minimal access left atrial maze : the Dallas lesion set", Ann Thorac Surg, 88, pp.1655~1657 (2009)
- Edgerton JR, "Totally thorascopic surgical ablation of persistent AF and long-standing persistent atrial fibrillation using the "Dallas" lesion set", Heart Rhythm, 6, pp.S64~S70 (2009)
- Lockwood D, "Linear left atrial lesions in minimally invasive surgical ablation of persistent atrial fibrillation: techniques for assessing conduction block across surgical lesions", Heart Rhythm, 6, pp.S50~S63 (2009)
- Malaisrie SC, "Atrial fibrillation ablation in patients undergoing aortic valve replacement", J Heart Valve Dis, 21, pp.350~357 (2012)
- Cherniavsky A, "Assessment of results of surgical treatment for persistent atrial fibrillation during coronary artery bypass grafting using implantable loop recorders", Interact Cardiovasc Thorac Surg, 18, pp.727~731 (2014)
- Yoo JS, "Impact of concomitant surgical atrial fibrillation ablation in patients undergoing aortic valve replacement", Circ J, 78, pp.1364~1371 (2014)
- Cox JL, "Successful surgical treatment of atrial fibrillation. Review and clinical update", JAMA, 266, pp.1976~1980 (1991)
- Huffman MD, "Concomitant atrial fibrillation surgery for people undergoing cardiac surgery", Cochrane Database Syst Rev, pp.CD011814~ (2016)
- Gammie JS, "Atrial fibrillation correction surgery: lessons from the Society of Thoracic Surgeons National Cardiac Database", Ann Thorac Surg, 85, pp.909~914 (2008)
- Chen MC, "Preoperative atrial size predicts the success of radiofrequency maze procedure for permanent atrial fibrillation in patients undergoing concomitant valvular surgery", Chest, 125, pp.2129~2134 (2004)
- Sunderland N, "What size of left atrium significantly impairs the success of maze surgery for atrial fibrillation", Interact Cardiovasc Thorac Surg, 13, pp.332~338 (2011)
- Chaiyaroj S, "Predictors of sinus rhythm after radiofrequency maze and mitral valve surgery", Asian Cardiovasc Thorac Ann, 16, pp.292~297 (2008)
- Gillinov AM, "Surgery for permanent atrial fibrillation: impact of patient factors and lesion set", Ann Thorac Surg, 82, pp.502~513 (2006)
- Bum Kim J, "Long-term outcomes of mechanical valve replacement in patients with atrial fibrillation : impact of the maze procedure", Circulation, 125, pp.2071~2080 (2012)
- Park SJ, "Effect of left atrial activity after the maze procedure on clinical and echocardiographic outcomes", Circ J, 78, pp.1584~1592 (2014)
- Je HG, "A systematic review of minimally invasive surgical treatment for atrial fibrillation: a comparison of the Cox-Maze procedure, beating-heart epicardial ablation, and the hybrid procedure on safety and efficacy", Eur J Cardiothorac Surg, 48, pp.531~540 (2015)
- Kim HJ, "Surgical ablation of atrial fibrillation in patients with a giant left atrium undergoing mitral valve surgery", Heart, 102, pp.1206~1214 (2016)
- Wi J, "Fate of preoperative atrial fibrillation after correction of atrial septal defect", Circ J, 77, pp.109~115 (2013)
- Im YM, "Arrhythmia surgery for atrial fibrillation associated with atrial septal defect: right-sided maze versus biatrial maze", J Thorac Cardiovasc Surg, 145, pp.648~654 (2013)
- Kim JB, "Maze procedure in patients with left ventricular dysfunction", Int J Cardiol, 170, pp.331~337 (2014)
- Damiano RJ Jr, "The long-term outcome of patients with coronary disease and atrial fibrillation undergoing the Cox maze procedure", J Thorac Cardiovasc Surg, 126, pp.2016~2021 (2003)
- Akpinar B, "Combined off-pump coronary artery bypass grafting surgery and ablative therapy for atrial fibrillation : early and mid-term results", Ann Thorac Surg, 81, pp.1332~1337 (2006)
- Geidel S, "Permanent atrial fibrillation ablation surgery in CABG and aortic valve patients is at least as effective as in mitral valve disease", Thorac Cardiovasc Surg, 54, pp.91~95 (2006)
- Geidel S, "Persistent atrial fibrillation ablation concomitant to coronary surgery", Thorac Cardiovasc Surg, 59, pp.207~212 (2011)
- Krul SP, "Navigating the mini-maze : systematic review of the first results and progress of minimallyinvasive surgery in the treatment of atrial fibrillation", Int J Cardiol, 166, pp.132~140 (2013)
- Kainuma S, "Dilated left atrium as a predictor of late outcome after pulmonary vein isolation concomitant with aortic valve replacement and", or coronary artery bypass graftingdagger, 2015, pp.48, 765~777
- Driessen AHG, "Ganglion Plexus Ablation in Advanced Atrial Fibrillation : The AFACT Study", J Am Coll Cardiol, 68, pp.1155~1165 (2016)
- Boersma LV, "Atrial fibrillation catheter ablation versus surgical ablation treatment(FAST) : a 2-center randomized clinical trial", Circulation, 125, pp.23~30 (2012)
- Cox JL, "The surgical treatment of atrial fibrillation. III. Development of a definitive surgical procedure", J Thorac Cardiovasc Surg, 101, pp.569~583 (1991)
- Wolf RK, "Video-assisted bilateral pulmonary vein isolation and left atrial appendage exclusion for atrial fibrillation", J Thorac Cardiovasc Surg, 130, pp.797~802 (2005)
- Edgerton JR, "Minimally invasive pulmonary vein isolation and partial autonomic denervation for surgical treatment of atrial fibrillation", Ann Thorac Surg, 86, pp.35~38 (2008)
- Edgerton JR, "Minimally invasive surgical ablation of atrial fibrillation: six-month results", J Thorac Cardiovasc Surg, 138, pp.109~113 (2009)
- Beyer E, "Point : Minimally invasive bipolar radiofrequency ablation of lone atrial fibrillation : early multicenter results", J Thorac Cardiovasc Surg, 137, pp.521~526 (2009)
- Kearney K, "A systematic review of surgical ablation versus catheter ablation for atrial fibrillation", Ann Cardiothorac Surg, 3, pp.15~29 (2014)
- Ad N, "Surgical ablation of atrial fibrillation trends and outcomes in North America", J Thorac Cardiovasc Surg, 144, pp.1051~1060 (2012)
- Driessen AH, "Electrophysiologically Guided Thoracoscopic Surgery for Advanced Atrial Fibrillation : 5-Year Follow-up", J Am Coll Cardiol, 69, pp.1753~1754 (2017)
- Khargi K, "Surgical treatment of atrial fibrillation; a systematic review", Eur J Cardiothorac Surg, 27, pp.258~265 (2005)
- Wazni OM, "Atrial arrhythmias after surgical maze : findings during catheter ablation", J Am Coll Cardiol, 48, pp.1405~1409 (2006)
- Magnano AR, "Mechanisms of atrial tachyarrhythmias following surgical atrial fibrillation ablation", J Cardiovasc Electrophysiol, 17, pp.366~373 (2006)
- McElderry HT, "Proarrhythmic aspects of atrial fibrillation surgery : mechanisms of postoperative macroreentrant tachycardias", Circulation, 117, pp.155~162 (2008)
- Zeng Y, "Recurrent atrial arrhythmia after minimally invasive pulmonary vein isolation for atrial fibrillation", Ann Thorac Surg, 90, pp.510~515 (2010)
- Calkins H, "2012 HRS", EHRA, Heart Rhythm, pp.2012, 9[DOI]
- Henn MC, "Late outcomes after the Cox maze IV procedure for atrial fibrillation", J Thorac Cardiovasc Surg, 150, pp.1168~1176 (2015)
- Pison L, "Hybrid thoracoscopic surgical and transvenous catheter ablation of atrial fibrillation", J Am Coll Cardiol, 60, pp.54~61 (2012)
- Jiang YQ, "The safety and efficacy of hybrid ablation for the treatment of atrial fibrillation:A meta-analysis", PLoS One, 13, pp.e0190170~ (2018)
- On YK, "Electrophysiologic Results After Thoracoscopic Ablation for Chronic Atrial Fibrillation", Ann Thorac Surg, 100, pp.1595~1602 (2015)
- Choi MS, "Staged hybrid procedure in persistent atrial fibrillation : safety, efficacy, and atrial tachyarrhythmia", J Thorac Dis, 9, pp.4844~4848 (2017)
