본문 바로가기
KERD
논문KCI 등재

Electrocardiogram Sampling Frequency Range Acceptable for Heart Rate Variability Analysis

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Objectives: Heart rate variability (HRV) has gained recognition as a noninvasive marker of autonomic activity. HRV is considered a promising tool in various clinical scenarios. The optimal electrocardiogram (ECG) sampling frequency required to ensure sufficient precision of R–R intervals for HRV analysis has not yet been determined. Here, we aimed to determine the acceptable ECG sampling frequency range by analyzing ECG signals from patients who visited an emergency department with the chief complaint of acute intoxication or overdose. Methods: The study included 83 adult patients who visited an emergency department with the chief complaint of acute poisoning. The original 1,000-Hz ECG signals were down-sampled to 500-, 250-, 100-, and 50-Hz sampling frequencies with linear interpolation. R–R interval data were analyzed for time-domain, frequency-domain, and nonlinear HRV parameters. Parameters derived from the data on down-sampled frequencies were compared with those derived from the data on 1,000-Hz signals, and Lin’s concordance correlation coefficients were calculated. Results: Down-sampling to 500 or 250 Hz resulted in excellent concordance. Signals down-sampled to 100 Hz produced acceptable results for time-domain analysis and Poincaré plots, but not for frequency-domain analysis. Down-sampling to 50 Hz proved to be unacceptable for both time- and frequency-domain analyses. At 50 Hz, the root-mean-squared successive differences and the power of high frequency tended to have high values and random errors. Conclusions: A 250- Hz sampling frequency would be acceptable for HRV analysis. When frequency-domain analysis is not required, a 100-Hz sampling frequency would also be acceptable.

Abstract

Objectives: Heart rate variability (HRV) has gained recognition as a noninvasive marker of autonomic activity. HRV is considered a promising tool in various clinical scenarios. The optimal electrocardiogram (ECG) sampling frequency required to ensure sufficient precision of R–R intervals for HRV analysis has not yet been determined. Here, we aimed to determine the acceptable ECG sampling frequency range by analyzing ECG signals from patients who visited an emergency department with the chief complaint of acute intoxication or overdose. Methods: The study included 83 adult patients who visited an emergency department with the chief complaint of acute poisoning. The original 1,000-Hz ECG signals were down-sampled to 500-, 250-, 100-, and 50-Hz sampling frequencies with linear interpolation. R–R interval data were analyzed for time-domain, frequency-domain, and nonlinear HRV parameters. Parameters derived from the data on down-sampled frequencies were compared with those derived from the data on 1,000-Hz signals, and Lin’s concordance correlation coefficients were calculated. Results: Down-sampling to 500 or 250 Hz resulted in excellent concordance. Signals down-sampled to 100 Hz produced acceptable results for time-domain analysis and Poincaré plots, but not for frequency-domain analysis. Down-sampling to 50 Hz proved to be unacceptable for both time- and frequency-domain analyses. At 50 Hz, the root-mean-squared successive differences and the power of high frequency tended to have high values and random errors. Conclusions: A 250- Hz sampling frequency would be acceptable for HRV analysis. When frequency-domain analysis is not required, a 100-Hz sampling frequency would also be acceptable.

참고문헌 (21)

  1. Task Force of the European Society of Cardiology, "Heart rate variability: standards of measurement, physiological interpretation and clinical use", Circulation, 93(5), pp.1043~1065 (1996)[DOI]
  2. Proctor KG, "Heart rate variability index in trauma patients", J Trauma, 63(1), pp.33~43 (2007)[DOI]
  3. Ong ME, "An observational, prospective study exploring the use of heart rate variability as a predictor of clinical outcomes in pre-hospital ambulance patients", Resuscitation, 78(3), pp.289~297 (2008)[DOI]
  4. Liu T, "Manifold ranking based scoring system with its application to cardiac arrest prediction: a retrospective study in emergency department patients", Comput Biol Med, 67, pp.74~82 (2015)[DOI]
  5. Dinleyici EC, "Heart rate variability in children with tricyclic antidepressant intoxication", Cardiol Res Pract, 2013, pp.196506~ (2013)
  6. Jeong J, "Heart rate variability analysis in acute poisoning by cholinesterase inhibitors", Signa Vitae, 13(2), pp.33~40 (2017)
  7. Bolanos M, "Comparison of heart rate variability signal features derived from electrocardiography and photoplethysmography in healthy individuals", Conf Proc IEEE Eng Med Biol Soc, 1, pp.4289~4294 (2006)
  8. Ziemssen T, "Influence of ECG sampling frequency on spectral analysis of RR intervals and baroreflex sensitivity using the EUROBAVAR data set", J Clin Monit Comput, 22(2), pp.159~168 (2008)[DOI]
  9. Mahdiani S, "Is 50 Hz high enough ECG sampling frequency for accurate HRV analysis?", Conf Proc IEEE Eng Med Biol Soc, 2015, pp.5948~5951 (2015)
  10. Mohebbi M, "Prediction of paroxysmal atrial fibrillation based on non-linear analysis and spectrum and bispectrum features of the heart rate variability signal", Comput Methods Programs Biomed, 105(1), pp.40~49 (2012)[DOI]
  11. Goldberger AL, "PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals", Circulation, 101(23), pp.E215~E220 (2000)[DOI]
  12. Tarvainen MP, "Kubios HRV: heart rate variability analysis software", Comput Methods Programs Biomed, 113(1), pp.210~220 (2014)[DOI]
  13. Lin LI, "A concordance correlation coefficient to evaluate reproducibility", Biometrics, 45(1), pp.255~268 (1989)[DOI]
  14. Lawrence I, "Assay validation using the concordance correlation coefficient", Biometrics, 48(2), pp.599~604 (1992)[DOI]
  15. Ellis RJ, "A careful look at ECG sampling frequency and R-peak interpolation on short-term measures of heart rate variability", Physiol Meas, 36(9), pp.1827~1852 (2015)[DOI]
  16. Brennan M, "Poincare plot interpretation using a physiological model of HRV based on a network of oscillators", Am J Physiol Heart Circ Physiol, 283(5), pp.H1873~H1886 (2002)[DOI]
  17. Bland JM, "Statistical methods for assessing agreement between two methods of clinical measurement", Lancet, 1(8476), pp.307~310 (1986)
  18. Krouwer JS, "Why Bland-Altman plots should use X, not (Y+X)", 2 when X is a reference method, 2008, pp.27(5), 778~780
  19. Vest AN, "Benchmarking heart rate variability toolboxes", J Electrocardiol, 50(6), pp.744~747 (2017)[DOI]
  20. Llamedo M, "QRS detectors performance comparison in public databases", Proceeding of 2014 Computing in Cardiology Conference (CinC), pp.357~360 (2014)
  21. Martel ML, "Etiologies of altered mental status in patients with presumed ethanol intoxication", Am J Emerg Med, 36(6), pp.1057~1059 (2018)[DOI]

관련 논문AI추천