Objectives: In order to devise the combination module transmitting bio signal and signal data remotely, as defect of wire‐wireless combination module was complemented by designing a single combination of wireless module and power supply module, a single system was implemented. Methods: Currently in case of wireless transmission, it had various problems causing by some factors such as buildings, obstruction, and entanglement of wires and so on. In order to overcome problems of wireless transmission, a single combination module design was researched, which transmits vital signal and sign data using basic electric line installed in the inner building or between others. Even though it was also possible of wireless communication and the internet, in case of a power supply without them, it could be possible to transfer data to underground or top ground in the inner building without any special communication line. Results: Bio signal data was transmitted through a power supply line, a noise problem occurred would be solved by the designed noise filter. The filter showed that noise was cut off about more than 90%. It was also confirmed that the used ECG signals was stably received on transmission experiment. An internal PCB antenna could make the system be wireless communication without the disclosure of an antenna. Conclusions: In this study, in order to implement a useful system transmitting bio signal and data through wire and wireless management for combination design of wireless module and electrical line module, bio signal transmission system was implemented by design of noise break filter circuit to reduce power noise and PCB internal antenna design.

Abstract

Objectives: In order to devise the combination module transmitting bio signal and signal data remotely, as defect of wire‐wireless combination module was complemented by designing a single combination of wireless module and power supply module, a single system was implemented. Methods: Currently in case of wireless transmission, it had various problems causing by some factors such as buildings, obstruction, and entanglement of wires and so on. In order to overcome problems of wireless transmission, a single combination module design was researched, which transmits vital signal and sign data using basic electric line installed in the inner building or between others. Even though it was also possible of wireless communication and the internet, in case of a power supply without them, it could be possible to transfer data to underground or top ground in the inner building without any special communication line. Results: Bio signal data was transmitted through a power supply line, a noise problem occurred would be solved by the designed noise filter. The filter showed that noise was cut off about more than 90%. It was also confirmed that the used ECG signals was stably received on transmission experiment. An internal PCB antenna could make the system be wireless communication without the disclosure of an antenna. Conclusions: In this study, in order to implement a useful system transmitting bio signal and data through wire and wireless management for combination design of wireless module and electrical line module, bio signal transmission system was implemented by design of noise break filter circuit to reduce power noise and PCB internal antenna design.

참고문헌 (10)

  1. Gangmin Ning, "New Approaches to Physiological Study by Telemetry Technology", Engineering in Medicine and Biology Society, pp.6654~6657 (2005)
  2. Varshney. U, "Pervasive healthcare", Computer, 36(12), pp.138~140 (2003)
  3. Lubrin. E, "Wireless remote healthcare monitoring withMotes", ICMB, pp.235~241 (2005)
  4. E. Jovanov, "Wireless personal area networks in telemedical environment", in Proc. 3rd Int. Conf. Inf. Technol. Biomed. (ITAB‐ITIS2000), pp.22~27 (2000)
  5. Jung, J.Y, "ImprovedWBAN communication at mental healthcare system with the personalized bio signal devices", ICACT 2006. The 8th International Conference, 통권 : 1, pp.809~812 (2006), Advanced Communication Technology
  6. Jung, J.Y, "Improved ZigBee Connection Method for Healthcare Device", ICHIT '06. International Conference, 통권 : 1, pp.673~676 (2006), Hybrid Information Technology
  7. Schepps. J, "Microwave industry outlook wireless communications in healthcare", Microwave Theory and Techniques, 50(3), pp.1044~1045 (2002)
  8. Chan‐Young Yun, "A Design of A Mobile Remote Monitoring PDA Prototype Base on Embedded Linux with Wireless LAN Environment", Journal of Korean Society of Medical Informatics, 10(4), pp.407~141 (2004)
  9. Lopes, P A. C, "Determination of Biological Expression Signals on a New Handheld Biochip‐based Microsystem", Biomedical Circuits and Systems Conference, pp.57~60 (2006)
  10. S.H. Lee, "A study on the Development of Integrated Biosignal Management System", Journal of Korean Society of Medical Informatics, 4(2), pp.17~23 (1998)

관련 논문AI추천

이 간행물의 다른 논문 (10건)