본문 바로가기
KERD
논문KCI 등재

Integrated Solution for Physical Activity Monitoring Based on Mobile Phone and PC

0

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

Objectives: This study is part of the ongoing development of treatment methods for metabolic syndrome (MS) project, which involves monitoring daily physical activity. In this study, we have focused on detecting walking activity from subjects which includes many other physical activities such as standing, sitting, lying, walking, running, and falling. Specially, we implemented an integrated solution for various physical activities monitoring using a mobile phone and PC. Methods: We put the iPod touch has built in a tri-axial accelerometer on the waist of the subjects, and measured change in acceleration signal according to change in ambulatory movement and physical activities. First, we developed of programs that are aware of step counts,velocity of walking, energy consumptions, and metabolic equivalents based on iPod. Second, we have developed the activity recognition program based on PC. iPod synchronization with PC to transmit measured data using iPhoneBrowser program. Using the implemented system, we analyzed change in acceleration signal according to the change of six activity patterns. Results: We compared results of the step counting algorithm with different positions. The mean accuracy across these tests was 99.6 ± 0.61%, 99.1 ± 0.87% (right waist location, right pants pocket). Moreover, six activities recognition was performed using Fuzzy c means classification algorithm recognized over 98% accuracy. In addition we developed of programs that synchronization of data between PC and iPod for long-term physical activity monitoring. Conclusions: This study will provide evidence on using mobile phone and PC for monitoring various activities in everyday life. The next step in our system will be addition of a standard value of various physical activities in everyday life such as household duties and a health guideline how to select and plan exercise considering one’s physical characteristics and condition.

Abstract

Objectives: This study is part of the ongoing development of treatment methods for metabolic syndrome (MS) project, which involves monitoring daily physical activity. In this study, we have focused on detecting walking activity from subjects which includes many other physical activities such as standing, sitting, lying, walking, running, and falling. Specially, we implemented an integrated solution for various physical activities monitoring using a mobile phone and PC. Methods: We put the iPod touch has built in a tri-axial accelerometer on the waist of the subjects, and measured change in acceleration signal according to change in ambulatory movement and physical activities. First, we developed of programs that are aware of step counts,velocity of walking, energy consumptions, and metabolic equivalents based on iPod. Second, we have developed the activity recognition program based on PC. iPod synchronization with PC to transmit measured data using iPhoneBrowser program. Using the implemented system, we analyzed change in acceleration signal according to the change of six activity patterns. Results: We compared results of the step counting algorithm with different positions. The mean accuracy across these tests was 99.6 ± 0.61%, 99.1 ± 0.87% (right waist location, right pants pocket). Moreover, six activities recognition was performed using Fuzzy c means classification algorithm recognized over 98% accuracy. In addition we developed of programs that synchronization of data between PC and iPod for long-term physical activity monitoring. Conclusions: This study will provide evidence on using mobile phone and PC for monitoring various activities in everyday life. The next step in our system will be addition of a standard value of various physical activities in everyday life such as household duties and a health guideline how to select and plan exercise considering one’s physical characteristics and condition.

참고문헌 (25)

  1. Zimmet P, "Global and societal implications of the diabetes epidemic", Nature, 414, pp.782~787 (2001)
  2. Grundy SM, "Clinical management of metabolic syndrome: report of the American Heart Association", National Heart, Lung, and Blood Institute, Circulation, pp.2004, 109[DOI]
  3. Eckel RH, "The metabolic syndrome", Lancet, 365, pp.1415~1428 (2005)
  4. Thompson PD, "American Heart Association Council on Clinical Cardiology Subcommittee on Exercise, Rehabilitation, and Prevention; American Heart Association Council on Nutrition, Physical Activity, and Metabolism Subcommittee on Physical Activity. Exercise and physical activity in the prevention and treatment of atherosclerotic cardiovascular disease: a statement from the Council on Clinical Cardiology (Subcommittee on Exercise, Rehabilitation, and Prevention) and the Council on Nutrition, Physical Activity, and Metabolism (Subcommittee on Physical Activity)", Circulation, 107, pp.3109~3116 (2003)
  5. Tuomilehto J, "Prevention of type 2 diabetes mellitus by changes in lifestyle among subjects with impaired glucose tolerance", N Engl J Med, 344, pp.1343~1350 (2001)
  6. Lee M, "Review of daily physical activity monitoring system based on single triaxial accelerometer and portable data measurement unit", Lect Notes Electr En, 68, pp.569~580 (2010)
  7. Bassett DR Jr, "Validity and reliability issues in objective monitoring of physical activity", Res Q Exerc Sport, 71(2 Suppl), pp.S30~S36 (2000)
  8. Craig CL, "International physical activity questionnaire: 12-country reliability and validity", Med Sci Sports Exerc, 35, pp.1381~1395 (2003)
  9. Allor KM, "Stability and convergent validity of three physical activity assessments", Med Sci Sports Exerc, 33, pp.671~676 (2001)
  10. LaMonte MJ, "Assessment of physical activity and energy expenditure, in Obesity: etiology, assessment, treatment, and prevention", pp.111~117 (2003), Human Kinetics
  11. 홍주현, "A Belt-type Biomedical Mobile Device", Healthcare Informatics Research, 15(3), pp.351~358 (2009), 대한의료정보학회
  12. Mladenov M, "A step counter service for Java-enabled devices using a built-in accelerometer, in CAMS '09 Proceedings of the 1st International Workshop on Context-Aware Middleware and Services: affiliated with the 4th International Conference on Communication System Software and Middleware (COMSWARE 2009)", pp.1~5 (2009), Association for Computing Machinery
  13. Walters DL, "A mobile phone-based care model for outpatient cardiac rehabilitation: the care assessment platform (CAP)", BMC Cardiovasc Disord, 10, pp.5~ (2010)
  14. "Nokia Step Counter" (2009)[URL]
  15. Gyorbiro N, "An activity recognition system for mobile phones", Mob Netw Appl, 14, pp.82~91 (2009)
  16. Holzinger A, "Chances of increasing youth health awareness through mobile wellness applications", Lect Notes Comput Sci, 6389, pp.71~81 (2010)
  17. Rowlands D, "An architecture for iPod", iPhone applications in field sports, ~
  18. ". Cupertino, CA: Apple Inc" (2010)[URL]
  19. "Accelerometer Data" (2009)[URL]
  20. Bezdek JC, "Pattern recognition with fuzzy objective function algorithms" (1981), Plenum Press
  21. Dunn JC, "A fuzzy relative of the ISODATA process and its use in detecting compact well-separated clusters", J Cybern, 3, pp.32~57 (1973)
  22. Nascimento S, "Modeling proportional membership in fuzzy clustering", IEEE Trans Fuzzy Syst, 11, pp.173~186 (2003)
  23. Eng JJ, "Functional walk tests in individuals with stroke: relation to perceived exertion and myocardial exertion", Stroke, 33, pp.756~761 (2002)
  24. Brooks D, "Discharge criteria from perioperative physical therapy", Chest, 121, pp.488~494 (2002)
  25. Bidargaddi N, "Detecting walking activity in cardiac rehabilitation by using accelerometer", 3rd International Conference on Intelligent Sensors, Sensor Networks and Information, pp.555~560 (2007)

관련 논문AI추천

이 간행물의 다른 논문 (11건)