네일 숍 종사자들의 공기 중 아세톤 노출농도와 뇨 중 아세톤을 통한 생물학적 모니터링에 관한 연구
A Study on Exposure of Nail Shop Employees to Airborne Aceton and Biological Monitoring in Aceton acid
1
조회
0
다운로드
6
인용
0
참고문헌
키워드
초록
This study is made up of work environment measurement in order to examine the exposure of nail shop employees to Airborne Aceton and to perform experimental research on biological monitoring. First, acetone, which is a result of the acetone found in nail shops were found to be 5.630000 mg/L among nail shop employees and the acetone in the controlled group unexposed to hazardous chemicals were 1.2111761 mg/L, showing that nail shop employees had a much higher average density for acetone. Second, after conducting correlation analysis on the nail shop air density and biological monitoring, in the case of acetone, results of correlation analysis for acetone acid showed because of the low density of nail shop air, it did not have a relationship to acetone acid density. In the case of acetone, there was a correlation between the acetone density in the nail shop and in the acetone density in people. This represents that acetone density in the body increases whenever the acetone density increases in the air.
Abstract
This study is made up of work environment measurement in order to examine the exposure of nail shop employees to Airborne Aceton and to perform experimental research on biological monitoring. First, acetone, which is a result of the acetone found in nail shops were found to be 5.630000 mg/L among nail shop employees and the acetone in the controlled group unexposed to hazardous chemicals were 1.2111761 mg/L, showing that nail shop employees had a much higher average density for acetone. Second, after conducting correlation analysis on the nail shop air density and biological monitoring, in the case of acetone, results of correlation analysis for acetone acid showed because of the low density of nail shop air, it did not have a relationship to acetone acid density. In the case of acetone, there was a correlation between the acetone density in the nail shop and in the acetone density in people. This represents that acetone density in the body increases whenever the acetone density increases in the air.
참고문헌 (10)
- 박은정, "네일 숍 고객의 라이프스타일과 서비스만족도에 따른 재 방문에 관한 연구", 석사, pp.2008
- 이종대, "학교 실내공기질 및 휘발성 유기화합물 노출평가", 박사, pp.2008
- 조영민, "작업장에서의 유해 유기용제 폭로에 관한 연구", 환경영양평가, 9(1), pp.75~86 (2001)
- 박규미, "컬러링 제거에 사용된 아세톤 농도와 처치 시간에 따른 손톱의 손상도", 석사, pp.2003
- Ernest A. Trevino, "Infections in Nail Salons, Clinical Microbiology Newsletter, environment", Science of The Total Environment, 30(2), pp.9~11 (2008)
- 화학물질에 의한 건강장애 예방 연구결과, "노동부", 179~ (2005)
- 김형아, "화학물질 폭로에 대한 생물학적 모니터링", Korea J. Occup.Health, 29(3), pp.142~ (1990)
- 이원철, "작업장 환경의 특성 파악", Korea J. Occup. Health, 32(2), pp.69~74 (1993)
- J. R. Girman, "Emissions of volati le organic compounds from adhesives with indoor applic ations", Environment International, 12(4), pp.556~ (1986)
- 화학물질 노출기준 개정연구 -아세톤, "이세훈", 9~10 (2005)