네일샵 미용실의 실내공기 중 미세먼지(PM10), 휘발성 유기화합물 (VOCs), 알데하이드류(Aldehydes)의 농도 및 업소 특성에 따른 상관성 분석
Characteristics of PM10, VOCs and Aldehydes Levels in Nail and Hair Shops
1
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
Objectives: The purpose of this study was to assess the indoor levels of PM10, VOCs and aldehydes in nail shop and hair salon. Methods: The field survey was conducted for 52 hair salons 52 nail shops, and 26 shop-in-shops in Seoul and Daegu city. The field technicians investigated characteristics of each shop including operating time, indoor volume, ventilation and so on. Indoor concentrations of PM10, VOCs and aldehydes, indoor temperature and humidity were measured in 12 hair salons, 12 nail shops and 6 shop-in shops. MP Surveryor II (Graywolf, USA) was used to measure CO₂ concentration, temperature and humidity for 8 hours. PM10 concentrations were measured by minivolume air sampler with Teflon quartz filter (0.2 μm pore size, φ 47 mm, Graseby-Anderson TEF-DISKTM) for 6 hours. VOCs passive sampler (OVM 3500) was used to collect VOCs for 8 hours and analyzed by GC/MSD. Results: The CO₂ concentrations were 759.4±58.2 ppm in nail shops, 731.0±72.5 ppm in hair salons, and 656.4±31.2 ppm in shop-in-shops. The PM10 concentrations were 27.5±14.2 μg/㎥ in nail shops, 33.1±6.3 μg/㎥ in hair salons, and 39.0±26.9 μg/㎥ in shop-in-shops. TVOCs concentrations were 3085.4±1667.8 μg/㎥ in nail shops, 2131.1±617.3 μg/㎥ in hair salons, and 1550.3±529.0 μg/㎥ in shop-in-shops. TVOCs concentrations in nail shops were significantly higher than those in hair salons and shop-in-shops (p=0.002). Formaldehyde concentrations were 60.8±36.6 μg/㎥ in nail shops, 89.1±55.4 μg/㎥ in hair salons, and 45.1±22.5 μg/㎥ in shop-in-shops. Conclusion: TVOCs concentrations in nail shop were the highest among others. TVOC concentrations in all stores exceeded indoor air quality stand of indoor air quality control in public –use facilities, etc act.
Abstract
Objectives: The purpose of this study was to assess the indoor levels of PM10, VOCs and aldehydes in nail shop and hair salon. Methods: The field survey was conducted for 52 hair salons 52 nail shops, and 26 shop-in-shops in Seoul and Daegu city. The field technicians investigated characteristics of each shop including operating time, indoor volume, ventilation and so on. Indoor concentrations of PM10, VOCs and aldehydes, indoor temperature and humidity were measured in 12 hair salons, 12 nail shops and 6 shop-in shops. MP Surveryor II (Graywolf, USA) was used to measure CO₂ concentration, temperature and humidity for 8 hours. PM10 concentrations were measured by minivolume air sampler with Teflon quartz filter (0.2 μm pore size, φ 47 mm, Graseby-Anderson TEF-DISKTM) for 6 hours. VOCs passive sampler (OVM 3500) was used to collect VOCs for 8 hours and analyzed by GC/MSD. Results: The CO₂ concentrations were 759.4±58.2 ppm in nail shops, 731.0±72.5 ppm in hair salons, and 656.4±31.2 ppm in shop-in-shops. The PM10 concentrations were 27.5±14.2 μg/㎥ in nail shops, 33.1±6.3 μg/㎥ in hair salons, and 39.0±26.9 μg/㎥ in shop-in-shops. TVOCs concentrations were 3085.4±1667.8 μg/㎥ in nail shops, 2131.1±617.3 μg/㎥ in hair salons, and 1550.3±529.0 μg/㎥ in shop-in-shops. TVOCs concentrations in nail shops were significantly higher than those in hair salons and shop-in-shops (p=0.002). Formaldehyde concentrations were 60.8±36.6 μg/㎥ in nail shops, 89.1±55.4 μg/㎥ in hair salons, and 45.1±22.5 μg/㎥ in shop-in-shops. Conclusion: TVOCs concentrations in nail shop were the highest among others. TVOC concentrations in all stores exceeded indoor air quality stand of indoor air quality control in public –use facilities, etc act.
참고문헌 (12)
- "National Establishment survey"[URL]
- Labrèche F, "Characterization of chemical exposures in hairdressing salons", Applied Occupational and Environmental Hygiene, 18(12), pp.1014~1021 (2003)
- "IARC monographs on the evaluation of carcinogenic risks to humans-classifications"[URL]
- Militello G, "Contact and primary irritant dermatitis of the nail unit diagnosis and tretment", Dermatology and Therapy, 20, pp.47~53 (2007)
- Study on managing hazardous substances in public hygiene Sector, "Jung JW", Korea Institute for Health and Affairs, ~ (2011)
- 김난희, "네일샵 종사자의 휘발성유기화합물 노출실태와 건강에 미치는 영향", 한국산업보건학회지, 27(1), pp.59~69 (2017), 한국산업보건학회[DOI]
- 손부순, "Indoor and Outdoor Concentrations of Air Pollutants in Beauty Shops at kwangju Area", 한국환경과학회지, 15(2), pp.101~106 (2006), 한국환경과학회
- Quach T, "Characterizing workplace exposures in Vietnamese women working in California nail salons", American Journal of Public Health, 101(1), pp.271~276 (2011)
- 김호현, "네일 숍(Nail Shop) 근무자의 휘발성유기화합물류 노출 및 자각증상평가", 한국실내환경학회지, 7(2), pp.101~112 (2010), 한국실내환경학회
- Ronda E, "Airborne exposure to chemical substances in hairdresser salons. Environmental monitoring and assessment", Environmental Monitoring and Assessment, 153(1), pp.83~93 (2009)
- Heymann, WR, "Nail cosmetics: Potential hazards", Journal of the American Academy of Dermatology, 57(6), pp.1069~1070 (2007)
- Gjølstad, M, "Occupational exposure to airborne solvents during nail sculpturing", Journal of Environmental Monitoring, 8(5), pp.537~542 (2006)
