본문 바로가기
KERD
논문KCI 등재

모 한방병원 한약재내 중금속과 이산화황 함량 및 잔류농약 분석 연구

Determination of Heavy Metals, Sulfur Dioxide and Residual Pepsticides in Oriental Medical Materials at SangJi University Oriental Medical Hospital

2

조회

0

다운로드

7

인용

0

참고문헌

키워드

주제분류한의학

초록

The purpose of this study was to analyze harmful heavy metals, sulfur dioxide and residual pesticides in 27 kinds of oriental medical materials. This study was carried out on 27 samples of oriental medical materials. The GC-ECD(Varian, CP-3800) was used to analyze residual pesticides. ICP-OES(Varian, Vista-MPX) was used to analyze lead, arsenic, cadmium. Mercury was analyzed by amalgamation method. A modified Monier-Williams method was used to analyze sulfur dioxide. Arsenic was detected less than 3(㎎/㎏) in 14 samples and was not detected 13 samples. Lead was detected less than 5(㎎/㎏) in 15 samples and was not detected 12 samples. Mercury was detected less than 0.2(㎎/㎏) in 15 samples and was not detected 12 samples. Cadmium was detected more than 0.3(㎎/㎏) in 3 samples was detected less than 0.3(㎎/㎏) in 16 samples and was not detected 11 samples. A few residual pesticides was detected, but all residual pesticides was safe. Sulfur dioxide was detected in all samples, but all residual sulfur dioxide was safe.

Abstract

The purpose of this study was to analyze harmful heavy metals, sulfur dioxide and residual pesticides in 27 kinds of oriental medical materials. This study was carried out on 27 samples of oriental medical materials. The GC-ECD(Varian, CP-3800) was used to analyze residual pesticides. ICP-OES(Varian, Vista-MPX) was used to analyze lead, arsenic, cadmium. Mercury was analyzed by amalgamation method. A modified Monier-Williams method was used to analyze sulfur dioxide. Arsenic was detected less than 3(㎎/㎏) in 14 samples and was not detected 13 samples. Lead was detected less than 5(㎎/㎏) in 15 samples and was not detected 12 samples. Mercury was detected less than 0.2(㎎/㎏) in 15 samples and was not detected 12 samples. Cadmium was detected more than 0.3(㎎/㎏) in 3 samples was detected less than 0.3(㎎/㎏) in 16 samples and was not detected 11 samples. A few residual pesticides was detected, but all residual pesticides was safe. Sulfur dioxide was detected in all samples, but all residual sulfur dioxide was safe.

참고문헌 (15)

  1. 차윤엽, "한약재내 중금속 함량 및 잔류농약 분석- 모 ��방병원 한약재 중심으로 -", 동의생리병리학회지, 21(1), pp.226~230 (2007), 대한동의병리학회
  2. Massaro, E.J, "Handbook of Human Toxicology", pp.149~188 (1990), New York, Boca Raton Press
  3. 장상문, "한약자원식물학", pp.26~40 (1999), 학문출판(주)
  4. 오창환, "건조방법에 따른 한약재 중 이산화황 잔류량 및 지표성분 변화", 생약학회지, 38(4), pp.299~304 (2007), 한국생약학회
  5. 정영호, "최신농약학", pp.147~148 (2004), 시그마프레스
  6. 식품의약품안전청, "식품의약품안전청 고시 제 2005-72호, 생약의 잔류농약 허용 기준 및 시험방법", ~ (2005)
  7. 김우성, "유통 한약재의 잔류농약 모니터링", 한국환경과학회지, 15(8), pp.811~817 (2006), 한국환경과학회
  8. 식품의약품안전청, "식품의약품안전청 고시 제 2007-190호, 생약의 잔류 이산화황 허용 기준 및 시험방법", ~ (2007)
  9. Ten, K.H, "Complex reaction of Zinc with organic matter extracted form sewage sludge", Soil Sci. Soc. Am. Proc, 35, pp.748~752 (1971)
  10. Rhee, S.J, "Effect of cadmium dose injection on peroxidative damage in rat liver", J. Korean Soc. Food Sci. Nutr, 21, pp.601~607 (1992)
  11. Rabinowits, M.B, "Lead metabolism in the normal human ; stable isotope studies", Science, 182, pp.275~ (1973)
  12. Nordberg, M, "General aspects of cadmium : transport, uptake and metabolism by the kidney", Environ. Health persp, 54, pp.13~20 (1984)
  13. 박창규, "서호의 수질, 저니토, 붕어 중 polychlorinated biphenyls 및 유기염소계 살충제의 잔류평가", 한국환경농화학회지, 1(2), pp.105~115 (1982)
  14. Kim, C.M, "Determination of Sulfite contents in medical herbs", J.Korean Soc. Food Sci. Nutur, 29(3), pp.375~379 (2000)
  15. Kang, K.J, "Naturally occurring of sulfur dioxide in medicinal herbs (crude drug materials) and its origin", Korean J. Food Sci. Technol, 33(5), pp.514~520 (2001)

관련 논문AI추천

이 간행물의 다른 논문 (26건)