적혈구 용적이 요골 동맥의 맥파에 미치는 영향
Effect of Hematocrit Level on the Radial Pulse Wave
0
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
In this work, we investigate the effect of blood hematocrit level on the radial pulse wave to study the clinical application of the pulse analyzer. For this purpose, we measured the radial pulse wave at the left Gwan for 15 males with abnormal high hematocrit level and 47 males with normal hematocrit level at the age of thirties and forties. Various variables of the radial pulse wave between two groups were analyzed by Student's T test. We found significant differences in several characteristic variables in the amplitude, time-span and the integrated area of the amplitude and time of the pulse wave. The systolic peak in the amplitude of the radial pulse wave was higher in abnormal high hematocrit group. In contrast, the third peak from the second incisure was higher and longer in normal hematocrit group. Our study suggests that the radial pulse wave can be useful in distinguishing the patient group with high hematocrit level and thus with high blood viscosity. Our finding may motivate research activities towards diverse clinical applications of the pulse wave.
Abstract
In this work, we investigate the effect of blood hematocrit level on the radial pulse wave to study the clinical application of the pulse analyzer. For this purpose, we measured the radial pulse wave at the left Gwan for 15 males with abnormal high hematocrit level and 47 males with normal hematocrit level at the age of thirties and forties. Various variables of the radial pulse wave between two groups were analyzed by Student's T test. We found significant differences in several characteristic variables in the amplitude, time-span and the integrated area of the amplitude and time of the pulse wave. The systolic peak in the amplitude of the radial pulse wave was higher in abnormal high hematocrit group. In contrast, the third peak from the second incisure was higher and longer in normal hematocrit group. Our study suggests that the radial pulse wave can be useful in distinguishing the patient group with high hematocrit level and thus with high blood viscosity. Our finding may motivate research activities towards diverse clinical applications of the pulse wave.
참고문헌 (21)
- 박영배, "맥진기의 현황과 전망", 대한한의진단학회지, 1(1), pp.86~94 (1997)
- 김경철, "脈診의 현대적인 객관화 연구를 위한 기반조사 - Ⅰ. 기계적 측정법에 대한 비교연구 -", 동의생리병리학회지, 17(5), pp.1147~1150 (2003), 대한동의병리학회
- Nichols, W.W., "McDonald's blood flow in arteries", pp.54~293 (2005), Hodder Arnold
- 신병철, "맥진기를 이용한 중풍 환자의 임상적 고찰", korean J. oriental Medical Pathology, 13(2), pp.123~127 (1999)
- 박영배, "비만증 환자의 맥파형 관찰", 대한한의학회지, 6(1), pp.112~116 (1985)
- 이시우, "어레이 압저항 센서를 활용한 체질맥 임상연구", 사상체질의학회지, 18(1), pp.118~131 (2006), 사상체질의학회
- Carmel, M., "function is associated with pulse pressure, pulse wave velocity, and augmentation Index in healthy humans", Hypertension, 48, pp.602~608 (2006)
- Wikinson, I.B., "Pulse-Wave analysis: Clinical evaluation of a noninvasive, widely applicable method for assessing endothelial function", Arterioscler Thromb Vascular Biology, 22, pp.147~152 (2002)
- Poiseuille, J.L.M., "Recherches experimentales surle movement des liquids dans les tubes de tres petits diameters", memoires Savant des Etrangers, 9, pp.433~544 (1846)
- G. Richard, "Wintrobe's clinical hematology", pp.2208~2209 (1993), Lea & Febiger
- Lee, Y.J., "The process of clinical test in pulse analyzer", The International Conference on Oriental Medicine, pp.62~65 (2005)
- Walsh, S., "Pulse Diagnosis. in: A Clinical Guide", pp.5~17 (2008), Elsevier
- 김경철, "맥 의공학 연구방법론", pp.66~89 (2008), 대요메디
- Cirillo, M., "Hematocrit blood pressure, and hypertension. The Gubbio Population Study", Hypertension, 20(3), pp.319~326 (1992)
- Göbel, B.O., "Arterial blood pressure. in: Correlation with erythrocyte count, hematocrit, and hemoglobin concentration", Am J Hypertens., 4, pp.14~19 (1991)
- Fossum, E., "Whole blood viscosity, blood pressure and cardiovascular risk factors in healthy blood donors", Blood Press, 6(3), pp.161~165 (1997)
- Ciuffetti, G., "Plasma viscosity in isolated systolic hypertension: the role of pulse pressure", Am J Hypertens, 18(7), pp.1005~1008 (2005)
- Yang, P.L., "Pulse pressure index (pulse pressure", systolic pressure) may be better than pulse pressure for assessment of cardiovascular outcomes, 2009, pp.72, 729~731
- González Quijada, S., "The association of hematocrit with blood pressure and left ventricular mass in subjects over 55", Rev Clin., 199(4), pp.202~207 (1999)
- De Simone, G., "Association of blood pressure with blood viscosity in american indians: the Strong Heart Study", Hypertension, 45(4), pp.625~630 (2005)
- Albert, L., "Non-Newtonian behavior of blood in oscillatory flow", Biophysical Journal, 7, pp.25~36 (1967)
