ObjectivesThe purpose of this study was to determine whether a pulse analyzer was useful to characterize the variablesof pulse wave of hypertension (HT), compared with those of normal blood pressure group (NP). MethodsThe subjects were 22,646 who worked at car manufacturing factory. The pulse wave variables and pulse typesmeasured in Guan by DMP 1000. ResultsIn the main and secondary pulse type, there were significant differences between HT and NP. Whereas, in thefield of pulse wave variables, no specific differences were between HT and NP. ConclusionAlthough pulse wave variables were not statistically significant, pulse analyzer might have reliable diagnosticsensitivity between hypertension and non-hypertension population. Key WordsHypertension, Pulse wave, Pulse type, Pulse analyzer
Abstract
ObjectivesThe purpose of this study was to determine whether a pulse analyzer was useful to characterize the variablesof pulse wave of hypertension (HT), compared with those of normal blood pressure group (NP). MethodsThe subjects were 22,646 who worked at car manufacturing factory. The pulse wave variables and pulse typesmeasured in Guan by DMP 1000. ResultsIn the main and secondary pulse type, there were significant differences between HT and NP. Whereas, in thefield of pulse wave variables, no specific differences were between HT and NP. ConclusionAlthough pulse wave variables were not statistically significant, pulse analyzer might have reliable diagnosticsensitivity between hypertension and non-hypertension population. Key WordsHypertension, Pulse wave, Pulse type, Pulse analyzer
참고문헌 (34)
- 이유정, "맥진기술동향 조사를 통한 맥진기 개발방안 제안", 동의생리병리학회지, 23(1), pp.174~179 (2009), 대한동의병리학회
- Park YB, "The development of pulse diagnostic apparatus enable to gain multi-information and it's clinical significance", Journal of Korean Oriental Med, 16(1), pp.499~504 (1995)
- Kim EG, "15 channel tonometric radial pulse measurement system using air cuff pressure", Journal of information and control system, pp.205~206 (2008)
- 이상석, "다중 홀소자를 이용한 맥진기의 3차원 파형 획득 연구", 한국자기학회지, 16(4), pp.216~220 (2006), 한국자기학회
- Lee YJ, "The effect of the BMI on the automatic pulse diagnosis on Korean traditional medicine", Journal of the Korean Magnetics society, pp.1904~1905 (2007)
- 하인영, "맥의 빠르기, 크기, 깊이에 관한 전통맥진과 기기측정 맥진의 비교 연구", Korean Journal of Acupuncture, 28(1), pp.23~37 (2011), 경락경혈학회
- 송민선, "맥진기를 이용한 인영촌구맥과 체질량지수 및 사상체질간의 관계연구", 동의생리병리학회지, 25(2), pp.339~344 (2011), 대한동의병리학회
- 신윤진, "脈診器를 이용한 아토피 피부염 환자의 임상적 고찰", 한방안이비인후피부과학회지, 21(2), pp.112~119 (2008), 대한한방안이비인후피부과학회
- 최용석, "어레이 압저항 센서 장착 맥진기의 고혈압 맥파 특성", Korean Journal of Acupuncture, 24(3), pp.105~116 (2007), 경락경혈학회
- 唐亞平, "體型胖瘦對脈象影響的硏究", 中國中醫基礎醫学杂誌, 15, pp.387~388 (2009)
- 唐亞平, "生理性因素的相關性研究", 遼寧中醫雜誌, 34, pp.1046~1047 (2007)
- 唐亞平, "生理性因素的相關性的研究", 時珍國醫國藥, 18, pp.2818~2819 (2007)
- Shin SH, "A study of the cardiovascular aging effect on the pulse shape", The Journal of The Korea Institute Of Oriental Medical Diagnostics, 9(1), pp.59~68 (2005)
- Korea Health Statistics, "Korea National Health and Nutrition Examination Survey (KNHANES V-2)", ~ (2011)
- 陳可, "高血壓弦脈的血液動力學分析", 中華內科雜誌, 19, pp.638~641 (1962)
- 趙思儉, "高血壓 88例 脈象圖分析", 天進醫學, 39(3), pp.34~128 (1982)
- 배성인, "맥진법의 의사학적 소고", 대한한의학경락진단학회지, 2, pp.114~128 (2003)
- 김현호, "문헌고찰 및 실측에 근거한 맥진기 측정시 촌관척 정위에 대한 제안", 대한한의학회지, 28(3), pp.13~22 (2007), 대한한의학회
- Lee YJ, "The Process of Clinical Test on Pulse Analyzer", The international conference on oriental medicine, pp.62~65 (2005)
- Shin SS, "A Study of the Cardiovascular Aging Effect on the Pulse Shape", The Journal of The Korea Institue of Oriental Medical Diagnostics, 9(1), pp.59~68 (2005)
- Nichols W, "McDonald’s blood flow in arteries. London: Arnold;1998.", Nurnberger J, Keflioglu-Scheiber A,Opazo Saez AM, Wenzel RR, Philipp T,Schafers RF. Augmentation index is associated with cardiovascular risk, 2002, pp.20, 2407~2414
- Weber T, "Arterial stiffness, wave reflections, and the risk of coronary artery disease", Circulation, 109, pp.184~189 (2004)
- London GM, "Arterial wave reflections and survival in end-stage renal failure", Hypertension, 38, pp.434~438 (2001)
- 이봉교, "한방진단학. 6판", pp.161~163 (2004), 성보사
- 임양근, "진단학아틀라스맥진", pp.11~205 (2003), 정담
- 朱文鋒, "中醫脈診與鑑別診斷學", pp.110~113 (1999), 人民衛生出版社
- 張洪義, "中醫臨床診斷全書", pp.46~49 (2002), 天津科學技術出版社
- 채인식, "한방임상학", pp.230~245 (2005), 의성당
- 陳德奎, "弦滑脈的血液動力學分析", 中西醫綜合雜誌, 3(4), pp.232~ (1983)
- 張保榮, "弦脈脈象臨床觀察報告", 湖北中醫雜誌, 3, pp.19~20 (2001)
- 이봉교, "맥진 현대화의 이론과 실제", pp.212~240 (2003), 성보사
- 김경철, "맥의공학 연구방법론", pp.83~86 (2008), 대요메디
- 강희정, "3차원 로봇 맥 영상 분석기의 5단계 가압 맥파 분석에 의한 고혈압 환자의 현맥(弦脈) 연구", Korean Journal of Acupuncture, 27(1), pp.1~12 (2010), 경락경혈학회
- 하예진, "펜타입 압저항 센서를 활용한 연령별 맥파 특성 및 맥파의 대사증후군에의 적용 가능성 평가", 대한한방내과학회지, 33(3), pp.257~271 (2012), 대한한방내과학회