3가지 성문위기도기(Supraglottic airway device)의 삽관 용이성과 삽관시간 비교 - 마네킨을 이용한 연구
Comparative assessment of the easiness and speed of insertion of three supraglottic airway devices - A manikin study -
1
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Purpose : This study was designed to compare the easiness and speed of insertion of three supraglottic airway devices(SADs) in a manikin setting. Methods : Three different SADs - Laryngeal Mask Classic(cLMA), I-gel and Streamlined Liner of the Pharynx Airway(SLIPA) were applied. One hundred and nineteen paramedical students with(group H) or without (group L) previous airway experience were taught brief manikin training about the use of the cLMA, I-gel and SLIPA. The students inserted each device in a randomized order. Time to effective ventilation was recorded in seconds from holding the device to the first chest inflation. Success was determined as adequate chest wall movement. Results : The insertion attempts were lesser in I-gel(1.00±0.00) and SLIPA(1.05±0.27) than cLMA(1.16±0.41, p<.05). The shortest time to insertion was recorded for I-gel(10.5±3.0 sec), followed by the SLIPA(12.9±4.5 sec) and cLMA(19.6±4.1 sec, p<.05). There were no significant differences in the insertion attempts and insertion time of I-gel between group L and group H. But in cLMA, longer insertion time and more insertion attempts were recorded in group L than group H. Conclusion : Both I-gel and SLIPA were superior to cLMA in the easiness and speed of insertion. Even in novice students, I-gel showed an excellent result in a manikin.
Abstract
Purpose : This study was designed to compare the easiness and speed of insertion of three supraglottic airway devices(SADs) in a manikin setting. Methods : Three different SADs - Laryngeal Mask Classic(cLMA), I-gel and Streamlined Liner of the Pharynx Airway(SLIPA) were applied. One hundred and nineteen paramedical students with(group H) or without (group L) previous airway experience were taught brief manikin training about the use of the cLMA, I-gel and SLIPA. The students inserted each device in a randomized order. Time to effective ventilation was recorded in seconds from holding the device to the first chest inflation. Success was determined as adequate chest wall movement. Results : The insertion attempts were lesser in I-gel(1.00±0.00) and SLIPA(1.05±0.27) than cLMA(1.16±0.41, p<.05). The shortest time to insertion was recorded for I-gel(10.5±3.0 sec), followed by the SLIPA(12.9±4.5 sec) and cLMA(19.6±4.1 sec, p<.05). There were no significant differences in the insertion attempts and insertion time of I-gel between group L and group H. But in cLMA, longer insertion time and more insertion attempts were recorded in group L than group H. Conclusion : Both I-gel and SLIPA were superior to cLMA in the easiness and speed of insertion. Even in novice students, I-gel showed an excellent result in a manikin.
참고문헌 (24)
- Neumar RW, "Part 8: Adult advanced cardiovascular life support: 2010 American heart association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care", Circulation, 122, pp.S729~S767 (2010)
- Lim TH, "Noninvasive airway management. In The Korean Society of Emergency Medicine, Emergency Medicine", pp.305~311 (2011), Koonja Publishing Co.
- Cho NS, "Endotracheal intubation and Mechanical ventilation. In The Korean Society of Emergency Medicine, Emergency Medicine", pp.323~335 (2011), Koonja Publishing Co.
- Wiese CH, "Using a laryngeal tube during cardiac arrest reduces “no flow time” in a manikin study: a comparison between laryngeal tube and endotracheal tube", Wien Klin Wochenschr, 120, pp.217~223 (2008)
- Gabrielli A, "Alternative ventilation strategies in cardiopulmonary resuscitation", Curr Opin Crit Care, 8(3), pp.199~211 (2002)
- Miller DM, "Presence of protein deposits on 'cleaned' re-usable anaesthetic equipment", Anaesthesia, 56(11), pp.1069~1072 (2001)
- Thew M, "Results of a company designed evaluation of the SLIPA", Anaesth Intensive Care, 36(4), pp.616~617 (2008)
- Levitan RM, "Initial anatomic investigations of the I-gel airway: a novel supraglottic airway without inflatable cuff", Anaesthesia, 60(10), pp.1022~1026 (2005)
- 최윤미, "The clinical effectiveness of the streamlined liner of pharyngeal airway (SLIPATM) compared with the laryngeal mask airway ProSealTM during general anesthesia", Korean Journal of Anesthesiology, 58(5), pp.450~457 (2010), 대한마취통증의학회
- 김유라, "마네킹을 이용한 병원 전 기도유지도구에 대한 비교 연구 - LMA ClassicTM, Cobra PLATM 및 King LTTM 비교", 대한응급의학회지, 21(6), pp.776~782 (2010), 대한응급의학회
- Korean Council of Professors for Emergency Medical Service, "Paramedic care Principle & Practice Introduction to advanced prehospital car, 2nd ed", pp.657~659 (2007), Daehakseorim
- 최욱진, "경추고정 마네킹에게 직접후두경(Macintosh laryngoscope), 부지(Gum elastic bougie), 비디오후두경(Pentax Airway Scope)을 사용한 기관내삽관 비교", 한국응급구조학회지, 15(3), pp.71~80 (2011), 사단법인 한국응급구조학회
- Tam RK, "Review of endotracheal intubations by Ottawa advanced care paramedics in Canada", Prehosp Emerg Care, 13(3), pp.311~315 (2009)
- Kokkinis K, "The use of the laryngeal mask airway in CPR", Resuscitation, 27(1), pp.9~12 (1994)
- Rumball CJ, "Combitube, laryngeal mask, and oral airway: a randomized prehospital comparative study of ventilatory device effectiveness and cost-effectiveness in 470 cases of cardiorespiratory arrest", Prehosp Emerg Care, 1(1), pp.1~10 (1997)
- 고재문, "응급의료에관한법률에 따른 1급 응급구조사 업무범위의 개선방안", 한국응급구조학회지, 11(3), pp.17~30 (2007), 사단법인 한국응급구조학회
- 김순심, "응급구조과 교과과정 개발", 한국응급구조학회지, 12(2), pp.5~26 (2008), 사단법인 한국응급구조학회
- "Analysis of appropriateness for prehospital field and transport emergency care" (2009), The Ministry of Health and Welfare
- Kette F, "The use of laryngeal tube by nurses in out-of-hospital emergencies: preliminary experience", Resuscitation, 66(1), pp.21~25 (2005)
- Levitan RM, "Initial anatomic investigations of the I-gel airway: a novel supraglottic airway without inflatable cuff", Anaesthesia, 60(10), pp.1022~1026 (2005)
- Lange M, "The effectiveness and patient comfort of the novel streamlined pharynx airway liner (SLIPA) compared with the conventional laryngeal mask airway in ophthalmic surgery", Anesth Analg, 104(2), pp.431~434 (2007)
- Weber U, "Comparison of the i-gel and the LMA-unique laryngeal mask airway in patient with mild to moderate obesity during elective short-term surgery", Anesthesia, 66(6), pp.481~487 (2011)
- Francksen H, "A comparison of the i-gelTM with the LMA-UniqueTM in non-paralysed anaesthetised adult patients", Anes- thesia, 64(10), pp.1118~1124 (2009)
- Stroumpoulis K, "A comparison of the i-gel and classic LMA insertion in manikins by experienced and novice physicians", Eur J Emerg Med, 19(1), pp.24~27 (2012)